Mixed convection in a ventilated 3D cavity : comparison of different LES models with experimental data

The aim of this work is to contribute to the progress in the determination of indoor airflow in buildings and to explore the possibility of coarse grid CFDsimulations for room airflow in building energy programs. To do so, a three dimensional ventilated cavity with mixed convection is simulated with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mohan Damle, Rashmin, Lehmkuhl Barba, Oriol, Colomer Rey, Guillem
Format: Text Resource
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Mohan Damle, Rashmin
Lehmkuhl Barba, Oriol
Colomer Rey, Guillem
description The aim of this work is to contribute to the progress in the determination of indoor airflow in buildings and to explore the possibility of coarse grid CFDsimulations for room airflow in building energy programs. To do so, a three dimensional ventilated cavity with mixed convection is simulated with different LES models and different meshes to see their influence on the numerical results. The Rayleigh number for this case is 2.23 x 109 and the Archimedes number is 0.036. This case is, to a certain extent, a representative of the flow that exists in real building rooms and is sufficiently complex for modelling. Also, the numerical results are compared with experimental data. Peer Reviewed
format Text Resource
fullrecord <record><control><sourceid>csuc_XX2</sourceid><recordid>TN_cdi_csuc_recercat_oai_recercat_cat_2072_185700</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_recercat_cat_2072_185700</sourcerecordid><originalsourceid>FETCH-csuc_recercat_oai_recercat_cat_2072_1857003</originalsourceid><addsrcrecordid>eNqdi7sKwkAQRdNYiPoP8wNCHkjEViMWWmkfhtlZHNhH2F1j_HtXEOwtLpfLOXde6ItMrIC8G5mSeAfiAGFkl8Rgyqg5AOEo6QW7rNkBg8SseQ1KtOaQTTh3V7BesYnwlHQHngYOYjNCAwoTLouZRhN59e1FUR272_60pvigPjBxIEy9R_mNT-qyrftqu2nLsvnn8wYl1kvW</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>text_resource</recordtype></control><display><type>text_resource</type><title>Mixed convection in a ventilated 3D cavity : comparison of different LES models with experimental data</title><source>Recercat</source><creator>Mohan Damle, Rashmin ; Lehmkuhl Barba, Oriol ; Colomer Rey, Guillem</creator><creatorcontrib>Mohan Damle, Rashmin ; Lehmkuhl Barba, Oriol ; Colomer Rey, Guillem</creatorcontrib><description>The aim of this work is to contribute to the progress in the determination of indoor airflow in buildings and to explore the possibility of coarse grid CFDsimulations for room airflow in building energy programs. To do so, a three dimensional ventilated cavity with mixed convection is simulated with different LES models and different meshes to see their influence on the numerical results. The Rayleigh number for this case is 2.23 x 109 and the Archimedes number is 0.036. This case is, to a certain extent, a representative of the flow that exists in real building rooms and is sufficiently complex for modelling. Also, the numerical results are compared with experimental data. Peer Reviewed</description><language>eng</language><subject>Aire ; Contaminació interior ; Física ; Física de la transmissió de la calor ; Indoor air pollution ; Mathematical models ; Termodinàmica ; Àrees temàtiques de la UPC</subject><creationdate>2011</creationdate><rights>info:eu-repo/semantics/openAccess</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,780,885,26974</link.rule.ids><linktorsrc>$$Uhttps://recercat.cat/handle/2072/185700$$EView_record_in_Consorci_de_Serveis_Universitaris_de_Catalunya_(CSUC)$$FView_record_in_$$GConsorci_de_Serveis_Universitaris_de_Catalunya_(CSUC)$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Mohan Damle, Rashmin</creatorcontrib><creatorcontrib>Lehmkuhl Barba, Oriol</creatorcontrib><creatorcontrib>Colomer Rey, Guillem</creatorcontrib><title>Mixed convection in a ventilated 3D cavity : comparison of different LES models with experimental data</title><description>The aim of this work is to contribute to the progress in the determination of indoor airflow in buildings and to explore the possibility of coarse grid CFDsimulations for room airflow in building energy programs. To do so, a three dimensional ventilated cavity with mixed convection is simulated with different LES models and different meshes to see their influence on the numerical results. The Rayleigh number for this case is 2.23 x 109 and the Archimedes number is 0.036. This case is, to a certain extent, a representative of the flow that exists in real building rooms and is sufficiently complex for modelling. Also, the numerical results are compared with experimental data. Peer Reviewed</description><subject>Aire</subject><subject>Contaminació interior</subject><subject>Física</subject><subject>Física de la transmissió de la calor</subject><subject>Indoor air pollution</subject><subject>Mathematical models</subject><subject>Termodinàmica</subject><subject>Àrees temàtiques de la UPC</subject><fulltext>true</fulltext><rsrctype>text_resource</rsrctype><creationdate>2011</creationdate><recordtype>text_resource</recordtype><sourceid>XX2</sourceid><recordid>eNqdi7sKwkAQRdNYiPoP8wNCHkjEViMWWmkfhtlZHNhH2F1j_HtXEOwtLpfLOXde6ItMrIC8G5mSeAfiAGFkl8Rgyqg5AOEo6QW7rNkBg8SseQ1KtOaQTTh3V7BesYnwlHQHngYOYjNCAwoTLouZRhN59e1FUR272_60pvigPjBxIEy9R_mNT-qyrftqu2nLsvnn8wYl1kvW</recordid><startdate>2011</startdate><enddate>2011</enddate><creator>Mohan Damle, Rashmin</creator><creator>Lehmkuhl Barba, Oriol</creator><creator>Colomer Rey, Guillem</creator><scope>XX2</scope></search><sort><creationdate>2011</creationdate><title>Mixed convection in a ventilated 3D cavity : comparison of different LES models with experimental data</title><author>Mohan Damle, Rashmin ; Lehmkuhl Barba, Oriol ; Colomer Rey, Guillem</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-csuc_recercat_oai_recercat_cat_2072_1857003</frbrgroupid><rsrctype>text_resources</rsrctype><prefilter>text_resources</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Aire</topic><topic>Contaminació interior</topic><topic>Física</topic><topic>Física de la transmissió de la calor</topic><topic>Indoor air pollution</topic><topic>Mathematical models</topic><topic>Termodinàmica</topic><topic>Àrees temàtiques de la UPC</topic><toplevel>online_resources</toplevel><creatorcontrib>Mohan Damle, Rashmin</creatorcontrib><creatorcontrib>Lehmkuhl Barba, Oriol</creatorcontrib><creatorcontrib>Colomer Rey, Guillem</creatorcontrib><collection>Recercat</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Mohan Damle, Rashmin</au><au>Lehmkuhl Barba, Oriol</au><au>Colomer Rey, Guillem</au><format>book</format><genre>document</genre><ristype>GEN</ristype><btitle>Mixed convection in a ventilated 3D cavity : comparison of different LES models with experimental data</btitle><date>2011</date><risdate>2011</risdate><abstract>The aim of this work is to contribute to the progress in the determination of indoor airflow in buildings and to explore the possibility of coarse grid CFDsimulations for room airflow in building energy programs. To do so, a three dimensional ventilated cavity with mixed convection is simulated with different LES models and different meshes to see their influence on the numerical results. The Rayleigh number for this case is 2.23 x 109 and the Archimedes number is 0.036. This case is, to a certain extent, a representative of the flow that exists in real building rooms and is sufficiently complex for modelling. Also, the numerical results are compared with experimental data. Peer Reviewed</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_csuc_recercat_oai_recercat_cat_2072_185700
source Recercat
subjects Aire
Contaminació interior
Física
Física de la transmissió de la calor
Indoor air pollution
Mathematical models
Termodinàmica
Àrees temàtiques de la UPC
title Mixed convection in a ventilated 3D cavity : comparison of different LES models with experimental data
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T22%3A19%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-csuc_XX2&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.btitle=Mixed%20convection%20in%20a%20ventilated%203D%20cavity%20:%20comparison%20of%20different%20LES%20models%20with%20experimental%20data&rft.au=Mohan%20Damle,%20Rashmin&rft.date=2011&rft_id=info:doi/&rft_dat=%3Ccsuc_XX2%3Eoai_recercat_cat_2072_185700%3C/csuc_XX2%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true