Measurement of Effective Dose of the Assisting Person in Diagnostic X-ray Examination

We measured the effective dose received by the person assisting the patient at diagnostic X-ray examination. Measurement was done when a patient's chest, abdomen, lumbar vertebrae, hip joint, skull, cervical vertebrae, or knee joint was examined by radiography. A body phantom including human bo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Japanese Journal of Radiological Technology 2004/12/20, Vol.60(12), pp.1739-1746
Hauptverfasser: NAKAMURA, KEIKO, IDE, RYOKO, SHIMIZU, AKIYO, SANADA, TAIZO
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1746
container_issue 12
container_start_page 1739
container_title Japanese Journal of Radiological Technology
container_volume 60
creator NAKAMURA, KEIKO
IDE, RYOKO
SHIMIZU, AKIYO
SANADA, TAIZO
description We measured the effective dose received by the person assisting the patient at diagnostic X-ray examination. Measurement was done when a patient's chest, abdomen, lumbar vertebrae, hip joint, skull, cervical vertebrae, or knee joint was examined by radiography. A body phantom including human bones exposed to radiation was used in the role of the patient. Some exposure conditions for these measurements were the same as those used routinely in computed radiography. Effective dose was measured directly with an ionization survey meter. As a result, the effective dose of the person assisting with axial projection of the hip joint was 124 fJiSv, which was higher than that for other regions and projections. If the assisting person helped a patient without using any protective device, the effective dose would be low enough to ignore. However, because medical staff are frequently exposed to radiation, optimal protection is crucial to prevent unnecessary radiation.
doi_str_mv 10.6009/jjrt.KJ00003560639
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_6009_jjrt_KJ00003560639</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>15614226</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2779-8145bc447ebf38cd148b52ae248ae553c9047e2788e39db0e241afd4cc6b56933</originalsourceid><addsrcrecordid>eNpVkF9PwjAUxRujEYJ8AR9Mv8CwXf-seySAimL0QRLflq67gxLYSDuMfHu7jGDow21y7u-ctAehe0pGkpD0cbNxzejtlYTDhCSSpVeoT5WiEVeKXaM-YTKNOCOih4be2zyAaZAIv0U9KiTlcSz7aPkO2h8c7KBqcF3iWVmCaewP4GntoVWaNeBxCPCNrVb4E5yvK2wrPLV6VdVBNfg7cvqIZ796Zyvd2Lq6Qzel3noYnu4BWj7NviYv0eLjeT4ZLyITJ0kaKcpFbjhPIC-ZMgXlKhexhpgrDUIwE16bQJwoBSwtchIWVJcFN0bmQqaMDVDc5RpXe--gzPbO7rQ7ZpRkbU1ZW1N2UVMwPXSm_SHfQfFvOZUSgHkHbHyjV3AGtAuf3UKXKUlG43ZehJ8Zs9Yug4r9AazcfXY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Measurement of Effective Dose of the Assisting Person in Diagnostic X-ray Examination</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>NAKAMURA, KEIKO ; IDE, RYOKO ; SHIMIZU, AKIYO ; SANADA, TAIZO</creator><creatorcontrib>NAKAMURA, KEIKO ; IDE, RYOKO ; SHIMIZU, AKIYO ; SANADA, TAIZO</creatorcontrib><description>We measured the effective dose received by the person assisting the patient at diagnostic X-ray examination. Measurement was done when a patient's chest, abdomen, lumbar vertebrae, hip joint, skull, cervical vertebrae, or knee joint was examined by radiography. A body phantom including human bones exposed to radiation was used in the role of the patient. Some exposure conditions for these measurements were the same as those used routinely in computed radiography. Effective dose was measured directly with an ionization survey meter. As a result, the effective dose of the person assisting with axial projection of the hip joint was 124 fJiSv, which was higher than that for other regions and projections. If the assisting person helped a patient without using any protective device, the effective dose would be low enough to ignore. However, because medical staff are frequently exposed to radiation, optimal protection is crucial to prevent unnecessary radiation.</description><identifier>ISSN: 0369-4305</identifier><identifier>EISSN: 1881-4883</identifier><identifier>DOI: 10.6009/jjrt.KJ00003560639</identifier><identifier>PMID: 15614226</identifier><language>eng ; jpn</language><publisher>Japan: Japanese Society of Radiological Technology</publisher><subject>Assisting person ; Diagnostic X-ray examination ; Effective dose ; Hip Joint - radiation effects ; Humans ; Lumbar Vertebrae - radiation effects ; Phantoms, Imaging ; Radiation Dosage ; Radiography ; Radiography, Abdominal ; Radiography, Thoracic ; Skull - radiation effects ; Technology, Radiologic</subject><ispartof>Japanese Journal of Radiological Technology, 2004/12/20, Vol.60(12), pp.1739-1746</ispartof><rights>2004 Japanese Society of Radiological Technology</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15614226$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>NAKAMURA, KEIKO</creatorcontrib><creatorcontrib>IDE, RYOKO</creatorcontrib><creatorcontrib>SHIMIZU, AKIYO</creatorcontrib><creatorcontrib>SANADA, TAIZO</creatorcontrib><title>Measurement of Effective Dose of the Assisting Person in Diagnostic X-ray Examination</title><title>Japanese Journal of Radiological Technology</title><addtitle>Jpn. J. Radiol. Technol.</addtitle><description>We measured the effective dose received by the person assisting the patient at diagnostic X-ray examination. Measurement was done when a patient's chest, abdomen, lumbar vertebrae, hip joint, skull, cervical vertebrae, or knee joint was examined by radiography. A body phantom including human bones exposed to radiation was used in the role of the patient. Some exposure conditions for these measurements were the same as those used routinely in computed radiography. Effective dose was measured directly with an ionization survey meter. As a result, the effective dose of the person assisting with axial projection of the hip joint was 124 fJiSv, which was higher than that for other regions and projections. If the assisting person helped a patient without using any protective device, the effective dose would be low enough to ignore. However, because medical staff are frequently exposed to radiation, optimal protection is crucial to prevent unnecessary radiation.</description><subject>Assisting person</subject><subject>Diagnostic X-ray examination</subject><subject>Effective dose</subject><subject>Hip Joint - radiation effects</subject><subject>Humans</subject><subject>Lumbar Vertebrae - radiation effects</subject><subject>Phantoms, Imaging</subject><subject>Radiation Dosage</subject><subject>Radiography</subject><subject>Radiography, Abdominal</subject><subject>Radiography, Thoracic</subject><subject>Skull - radiation effects</subject><subject>Technology, Radiologic</subject><issn>0369-4305</issn><issn>1881-4883</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkF9PwjAUxRujEYJ8AR9Mv8CwXf-seySAimL0QRLflq67gxLYSDuMfHu7jGDow21y7u-ctAehe0pGkpD0cbNxzejtlYTDhCSSpVeoT5WiEVeKXaM-YTKNOCOih4be2zyAaZAIv0U9KiTlcSz7aPkO2h8c7KBqcF3iWVmCaewP4GntoVWaNeBxCPCNrVb4E5yvK2wrPLV6VdVBNfg7cvqIZ796Zyvd2Lq6Qzel3noYnu4BWj7NviYv0eLjeT4ZLyITJ0kaKcpFbjhPIC-ZMgXlKhexhpgrDUIwE16bQJwoBSwtchIWVJcFN0bmQqaMDVDc5RpXe--gzPbO7rQ7ZpRkbU1ZW1N2UVMwPXSm_SHfQfFvOZUSgHkHbHyjV3AGtAuf3UKXKUlG43ZehJ8Zs9Yug4r9AazcfXY</recordid><startdate>200412</startdate><enddate>200412</enddate><creator>NAKAMURA, KEIKO</creator><creator>IDE, RYOKO</creator><creator>SHIMIZU, AKIYO</creator><creator>SANADA, TAIZO</creator><general>Japanese Society of Radiological Technology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200412</creationdate><title>Measurement of Effective Dose of the Assisting Person in Diagnostic X-ray Examination</title><author>NAKAMURA, KEIKO ; IDE, RYOKO ; SHIMIZU, AKIYO ; SANADA, TAIZO</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2779-8145bc447ebf38cd148b52ae248ae553c9047e2788e39db0e241afd4cc6b56933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2004</creationdate><topic>Assisting person</topic><topic>Diagnostic X-ray examination</topic><topic>Effective dose</topic><topic>Hip Joint - radiation effects</topic><topic>Humans</topic><topic>Lumbar Vertebrae - radiation effects</topic><topic>Phantoms, Imaging</topic><topic>Radiation Dosage</topic><topic>Radiography</topic><topic>Radiography, Abdominal</topic><topic>Radiography, Thoracic</topic><topic>Skull - radiation effects</topic><topic>Technology, Radiologic</topic><toplevel>online_resources</toplevel><creatorcontrib>NAKAMURA, KEIKO</creatorcontrib><creatorcontrib>IDE, RYOKO</creatorcontrib><creatorcontrib>SHIMIZU, AKIYO</creatorcontrib><creatorcontrib>SANADA, TAIZO</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Japanese Journal of Radiological Technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>NAKAMURA, KEIKO</au><au>IDE, RYOKO</au><au>SHIMIZU, AKIYO</au><au>SANADA, TAIZO</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurement of Effective Dose of the Assisting Person in Diagnostic X-ray Examination</atitle><jtitle>Japanese Journal of Radiological Technology</jtitle><addtitle>Jpn. J. Radiol. Technol.</addtitle><date>2004-12</date><risdate>2004</risdate><volume>60</volume><issue>12</issue><spage>1739</spage><epage>1746</epage><pages>1739-1746</pages><issn>0369-4305</issn><eissn>1881-4883</eissn><abstract>We measured the effective dose received by the person assisting the patient at diagnostic X-ray examination. Measurement was done when a patient's chest, abdomen, lumbar vertebrae, hip joint, skull, cervical vertebrae, or knee joint was examined by radiography. A body phantom including human bones exposed to radiation was used in the role of the patient. Some exposure conditions for these measurements were the same as those used routinely in computed radiography. Effective dose was measured directly with an ionization survey meter. As a result, the effective dose of the person assisting with axial projection of the hip joint was 124 fJiSv, which was higher than that for other regions and projections. If the assisting person helped a patient without using any protective device, the effective dose would be low enough to ignore. However, because medical staff are frequently exposed to radiation, optimal protection is crucial to prevent unnecessary radiation.</abstract><cop>Japan</cop><pub>Japanese Society of Radiological Technology</pub><pmid>15614226</pmid><doi>10.6009/jjrt.KJ00003560639</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0369-4305
ispartof Japanese Journal of Radiological Technology, 2004/12/20, Vol.60(12), pp.1739-1746
issn 0369-4305
1881-4883
language eng ; jpn
recordid cdi_crossref_primary_10_6009_jjrt_KJ00003560639
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Assisting person
Diagnostic X-ray examination
Effective dose
Hip Joint - radiation effects
Humans
Lumbar Vertebrae - radiation effects
Phantoms, Imaging
Radiation Dosage
Radiography
Radiography, Abdominal
Radiography, Thoracic
Skull - radiation effects
Technology, Radiologic
title Measurement of Effective Dose of the Assisting Person in Diagnostic X-ray Examination
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T17%3A21%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurement%20of%20Effective%20Dose%20of%20the%20Assisting%20Person%20in%20Diagnostic%20X-ray%20Examination&rft.jtitle=Japanese%20Journal%20of%20Radiological%20Technology&rft.au=NAKAMURA,%20KEIKO&rft.date=2004-12&rft.volume=60&rft.issue=12&rft.spage=1739&rft.epage=1746&rft.pages=1739-1746&rft.issn=0369-4305&rft.eissn=1881-4883&rft_id=info:doi/10.6009/jjrt.KJ00003560639&rft_dat=%3Cpubmed_cross%3E15614226%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/15614226&rfr_iscdi=true