X-ray Micro-Computed Tomography for monitoring the behavior of single particles under tensile strain
X-ray computed tomography was used to evaluate single particles that were artificially deposited in a polyethylene matrix, after interrupted tensile tests. Therefore, the prepared specimens were loaded from strain 0% to strain 30% with the CT500 Deben tension/compression in-situ stage (Deben, UK). S...
Gespeichert in:
Veröffentlicht in: | E-journal of Nondestructive Testing 2020-02, Vol.25 (2) |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 2 |
container_start_page | |
container_title | E-journal of Nondestructive Testing |
container_volume | 25 |
creator | Furtner, Sara Reiter, Michael Maurer, Julia Salaberger, Dietmar Kastner, Johann |
description | X-ray computed tomography was used to evaluate single particles that were artificially deposited in a polyethylene matrix, after interrupted tensile tests. Therefore, the prepared specimens were loaded from strain 0% to strain 30% with the CT500 Deben tension/compression in-situ stage (Deben, UK). Single particles and emerged defects were detected, characterised and assessed using VG Studio MAX 3.2. Within this work, different kinds and shapes of particles and defects were investigated. The elongation was measured and stress over strain curves were calculated. The shape of the particles has an impact on the defect formation. Spherical particles tend to be pulled out of the matrix while non spherical particles tend to rupture. |
doi_str_mv | 10.58286/25096 |
format | Article |
fullrecord | <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_58286_25096</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_58286_25096</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1006-cd4ed5e7d3da66c8a9532c31b6e5dcd4c6141f0dc7eb62a891e15bf843952fdb3</originalsourceid><addsrcrecordid>eNpNkE1LxDAYhIMouKzrb8jJWzXfTY9S_FhY8bKCt5Imb7aRtilJV9h_b1k9eJrhGRiYQeiWknupmVYPTJJKXaAVFVwWouLi8p-_RpucvwghTFe8ZGSF3GeRzAm_BZtiUcdhOs7g8D4O8ZDM1J2wjwkPcQxzTGE84LkD3EJnvsPCo8d5gT3gyaQ52B4yPo4OEp5hzGHheU4mjDfoyps-w-ZP1-jj-Wlfvxa795dt_bgrLCVEFdYJcBJKx51RympTSc4sp60C6ZbQKiqoJ86W0CpmdEWBytZrwSvJvGv5Gt399i5jck7gmymFwaRTQ0lzvqc538N_ABf8WNY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>X-ray Micro-Computed Tomography for monitoring the behavior of single particles under tensile strain</title><source>DOAJ Directory of Open Access Journals</source><creator>Furtner, Sara ; Reiter, Michael ; Maurer, Julia ; Salaberger, Dietmar ; Kastner, Johann</creator><creatorcontrib>Furtner, Sara ; Reiter, Michael ; Maurer, Julia ; Salaberger, Dietmar ; Kastner, Johann ; Upper Austrian University of Applied Sciences (FH OÖ) ; Borealis Polyolefine GmbH</creatorcontrib><description>X-ray computed tomography was used to evaluate single particles that were artificially deposited in a polyethylene matrix, after interrupted tensile tests. Therefore, the prepared specimens were loaded from strain 0% to strain 30% with the CT500 Deben tension/compression in-situ stage (Deben, UK). Single particles and emerged defects were detected, characterised and assessed using VG Studio MAX 3.2. Within this work, different kinds and shapes of particles and defects were investigated. The elongation was measured and stress over strain curves were calculated. The shape of the particles has an impact on the defect formation. Spherical particles tend to be pulled out of the matrix while non spherical particles tend to rupture.</description><identifier>ISSN: 1435-4934</identifier><identifier>EISSN: 1435-4934</identifier><identifier>DOI: 10.58286/25096</identifier><language>eng</language><ispartof>E-journal of Nondestructive Testing, 2020-02, Vol.25 (2)</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1006-cd4ed5e7d3da66c8a9532c31b6e5dcd4c6141f0dc7eb62a891e15bf843952fdb3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27923,27924</link.rule.ids></links><search><creatorcontrib>Furtner, Sara</creatorcontrib><creatorcontrib>Reiter, Michael</creatorcontrib><creatorcontrib>Maurer, Julia</creatorcontrib><creatorcontrib>Salaberger, Dietmar</creatorcontrib><creatorcontrib>Kastner, Johann</creatorcontrib><creatorcontrib>Upper Austrian University of Applied Sciences (FH OÖ)</creatorcontrib><creatorcontrib>Borealis Polyolefine GmbH</creatorcontrib><title>X-ray Micro-Computed Tomography for monitoring the behavior of single particles under tensile strain</title><title>E-journal of Nondestructive Testing</title><description>X-ray computed tomography was used to evaluate single particles that were artificially deposited in a polyethylene matrix, after interrupted tensile tests. Therefore, the prepared specimens were loaded from strain 0% to strain 30% with the CT500 Deben tension/compression in-situ stage (Deben, UK). Single particles and emerged defects were detected, characterised and assessed using VG Studio MAX 3.2. Within this work, different kinds and shapes of particles and defects were investigated. The elongation was measured and stress over strain curves were calculated. The shape of the particles has an impact on the defect formation. Spherical particles tend to be pulled out of the matrix while non spherical particles tend to rupture.</description><issn>1435-4934</issn><issn>1435-4934</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpNkE1LxDAYhIMouKzrb8jJWzXfTY9S_FhY8bKCt5Imb7aRtilJV9h_b1k9eJrhGRiYQeiWknupmVYPTJJKXaAVFVwWouLi8p-_RpucvwghTFe8ZGSF3GeRzAm_BZtiUcdhOs7g8D4O8ZDM1J2wjwkPcQxzTGE84LkD3EJnvsPCo8d5gT3gyaQ52B4yPo4OEp5hzGHheU4mjDfoyps-w-ZP1-jj-Wlfvxa795dt_bgrLCVEFdYJcBJKx51RympTSc4sp60C6ZbQKiqoJ86W0CpmdEWBytZrwSvJvGv5Gt399i5jck7gmymFwaRTQ0lzvqc538N_ABf8WNY</recordid><startdate>202002</startdate><enddate>202002</enddate><creator>Furtner, Sara</creator><creator>Reiter, Michael</creator><creator>Maurer, Julia</creator><creator>Salaberger, Dietmar</creator><creator>Kastner, Johann</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202002</creationdate><title>X-ray Micro-Computed Tomography for monitoring the behavior of single particles under tensile strain</title><author>Furtner, Sara ; Reiter, Michael ; Maurer, Julia ; Salaberger, Dietmar ; Kastner, Johann</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1006-cd4ed5e7d3da66c8a9532c31b6e5dcd4c6141f0dc7eb62a891e15bf843952fdb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Furtner, Sara</creatorcontrib><creatorcontrib>Reiter, Michael</creatorcontrib><creatorcontrib>Maurer, Julia</creatorcontrib><creatorcontrib>Salaberger, Dietmar</creatorcontrib><creatorcontrib>Kastner, Johann</creatorcontrib><creatorcontrib>Upper Austrian University of Applied Sciences (FH OÖ)</creatorcontrib><creatorcontrib>Borealis Polyolefine GmbH</creatorcontrib><collection>CrossRef</collection><jtitle>E-journal of Nondestructive Testing</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Furtner, Sara</au><au>Reiter, Michael</au><au>Maurer, Julia</au><au>Salaberger, Dietmar</au><au>Kastner, Johann</au><aucorp>Upper Austrian University of Applied Sciences (FH OÖ)</aucorp><aucorp>Borealis Polyolefine GmbH</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>X-ray Micro-Computed Tomography for monitoring the behavior of single particles under tensile strain</atitle><jtitle>E-journal of Nondestructive Testing</jtitle><date>2020-02</date><risdate>2020</risdate><volume>25</volume><issue>2</issue><issn>1435-4934</issn><eissn>1435-4934</eissn><abstract>X-ray computed tomography was used to evaluate single particles that were artificially deposited in a polyethylene matrix, after interrupted tensile tests. Therefore, the prepared specimens were loaded from strain 0% to strain 30% with the CT500 Deben tension/compression in-situ stage (Deben, UK). Single particles and emerged defects were detected, characterised and assessed using VG Studio MAX 3.2. Within this work, different kinds and shapes of particles and defects were investigated. The elongation was measured and stress over strain curves were calculated. The shape of the particles has an impact on the defect formation. Spherical particles tend to be pulled out of the matrix while non spherical particles tend to rupture.</abstract><doi>10.58286/25096</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1435-4934 |
ispartof | E-journal of Nondestructive Testing, 2020-02, Vol.25 (2) |
issn | 1435-4934 1435-4934 |
language | eng |
recordid | cdi_crossref_primary_10_58286_25096 |
source | DOAJ Directory of Open Access Journals |
title | X-ray Micro-Computed Tomography for monitoring the behavior of single particles under tensile strain |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T10%3A36%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=X-ray%20Micro-Computed%20Tomography%20for%20monitoring%20the%20behavior%20of%20single%20particles%20under%20tensile%20strain&rft.jtitle=E-journal%20of%20Nondestructive%20Testing&rft.au=Furtner,%20Sara&rft.aucorp=Upper%20Austrian%20University%20of%20Applied%20Sciences%20(FH%20O%C3%96)&rft.date=2020-02&rft.volume=25&rft.issue=2&rft.issn=1435-4934&rft.eissn=1435-4934&rft_id=info:doi/10.58286/25096&rft_dat=%3Ccrossref%3E10_58286_25096%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |