Voltammetric Determination of the Drug Metronidazole Using a Solid Bismuth Drop Electrode
Solid bismuth drop electrode (SBiDE) is a new working electrode commercially available on the Czech market since 2020 by the company Metrohm. The aim of this work was to verify the applicability of SBiDE for the voltammetric determination of a model organic substance representing electrochemically r...
Gespeichert in:
Veröffentlicht in: | Chemické listy 2024-11, Vol.118 (11), p.615-624 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 624 |
---|---|
container_issue | 11 |
container_start_page | 615 |
container_title | Chemické listy |
container_volume | 118 |
creator | Jarošová, Johanka Vyskočil, Vlastimil |
description | Solid bismuth drop electrode (SBiDE) is a new working electrode commercially available on the Czech market since 2020 by the company Metrohm. The aim of this work was to verify the applicability of SBiDE for the voltammetric determination of a model organic substance representing electrochemically reducible biologically active compounds, namely, the drug metronidazole (an antibiotic used to treat diseases caused by both Gram-positive and Gram-negative anaerobic bacteria). To the best of our knowledge, this is the very first published research work using SBiDE. Under optimum conditions (Britton-Robinson buffer of pH 12.0 was used as the supporting electrolyte and the working electrode surface was not electrochemically regenerated), a linear calibration dependence of metronidazole was obtained using differential pulse voltammetry (DPV) in the concentration range from 1 to 600 μmol L–1, with the limits of detection (LOD) and quantification (LOQ) of 0.41 μmol L–1 and 1.4 μmol L–1, respectively. Cyclic voltammetry (CV) on SBiDE was used to characterize the electrode process of the irreversible reduction of metronidazole. The newly developed DPV method was also successfully applied for the determination of metronidazole in authentic drinking water samples (LOD = 1.8 μmol L−1 and LOQ = 5.8 μmol L−1) and in various dosage forms (UV-Vis spectrophotometry was used as a comparative analytical method).
Full text English translation is available in the on-line version. |
doi_str_mv | 10.54779/chl20240615 |
format | Article |
fullrecord | <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_54779_chl20240615</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_54779_chl20240615</sourcerecordid><originalsourceid>FETCH-LOGICAL-c160t-9450d45b3c6c72816fc503aa374fd20d0d36712037b55f07e6c789eb1cf56a063</originalsourceid><addsrcrecordid>eNpN0L1OwzAYhWELgUQobFyAL4DAZzu2mxH6A0hFDFAkpsjxT2OUxJXtDnD1RMDAdJZHZ3gRuiRwzSsp6xvd9RRoBYLwI1QQSlgpCbBjVABAXVIp4RSdpfQBUBFS0wK9v4U-q2GwOXqNlzbbOPhRZR9GHBzOncXLeNjhpwmE0Rv1FXqLt8mPO6zwS-i9wXc-DYfcTTDs8aq3eqLGnqMTp_pkL_52hrbr1eviodw83z8ubjelJgJyWVccTMVbpoWWdE6E0xyYUkxWzlAwYJiQhAKTLecOpJ3YvLYt0Y4LBYLN0NXvr44hpWhds49-UPGzIdD8ZGn-ZWHfWxNVvw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Voltammetric Determination of the Drug Metronidazole Using a Solid Bismuth Drop Electrode</title><source>Full-Text Journals in Chemistry (Open access)</source><source>Elektronische Zeitschriftenbibliothek</source><source>Alma/SFX Local Collection</source><creator>Jarošová, Johanka ; Vyskočil, Vlastimil</creator><creatorcontrib>Jarošová, Johanka ; Vyskočil, Vlastimil</creatorcontrib><description>Solid bismuth drop electrode (SBiDE) is a new working electrode commercially available on the Czech market since 2020 by the company Metrohm. The aim of this work was to verify the applicability of SBiDE for the voltammetric determination of a model organic substance representing electrochemically reducible biologically active compounds, namely, the drug metronidazole (an antibiotic used to treat diseases caused by both Gram-positive and Gram-negative anaerobic bacteria). To the best of our knowledge, this is the very first published research work using SBiDE. Under optimum conditions (Britton-Robinson buffer of pH 12.0 was used as the supporting electrolyte and the working electrode surface was not electrochemically regenerated), a linear calibration dependence of metronidazole was obtained using differential pulse voltammetry (DPV) in the concentration range from 1 to 600 μmol L–1, with the limits of detection (LOD) and quantification (LOQ) of 0.41 μmol L–1 and 1.4 μmol L–1, respectively. Cyclic voltammetry (CV) on SBiDE was used to characterize the electrode process of the irreversible reduction of metronidazole. The newly developed DPV method was also successfully applied for the determination of metronidazole in authentic drinking water samples (LOD = 1.8 μmol L−1 and LOQ = 5.8 μmol L−1) and in various dosage forms (UV-Vis spectrophotometry was used as a comparative analytical method).
Full text English translation is available in the on-line version.</description><identifier>ISSN: 0009-2770</identifier><identifier>EISSN: 1213-7103</identifier><identifier>DOI: 10.54779/chl20240615</identifier><language>eng</language><ispartof>Chemické listy, 2024-11, Vol.118 (11), p.615-624</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0001-9465-3931</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Jarošová, Johanka</creatorcontrib><creatorcontrib>Vyskočil, Vlastimil</creatorcontrib><title>Voltammetric Determination of the Drug Metronidazole Using a Solid Bismuth Drop Electrode</title><title>Chemické listy</title><description>Solid bismuth drop electrode (SBiDE) is a new working electrode commercially available on the Czech market since 2020 by the company Metrohm. The aim of this work was to verify the applicability of SBiDE for the voltammetric determination of a model organic substance representing electrochemically reducible biologically active compounds, namely, the drug metronidazole (an antibiotic used to treat diseases caused by both Gram-positive and Gram-negative anaerobic bacteria). To the best of our knowledge, this is the very first published research work using SBiDE. Under optimum conditions (Britton-Robinson buffer of pH 12.0 was used as the supporting electrolyte and the working electrode surface was not electrochemically regenerated), a linear calibration dependence of metronidazole was obtained using differential pulse voltammetry (DPV) in the concentration range from 1 to 600 μmol L–1, with the limits of detection (LOD) and quantification (LOQ) of 0.41 μmol L–1 and 1.4 μmol L–1, respectively. Cyclic voltammetry (CV) on SBiDE was used to characterize the electrode process of the irreversible reduction of metronidazole. The newly developed DPV method was also successfully applied for the determination of metronidazole in authentic drinking water samples (LOD = 1.8 μmol L−1 and LOQ = 5.8 μmol L−1) and in various dosage forms (UV-Vis spectrophotometry was used as a comparative analytical method).
Full text English translation is available in the on-line version.</description><issn>0009-2770</issn><issn>1213-7103</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpN0L1OwzAYhWELgUQobFyAL4DAZzu2mxH6A0hFDFAkpsjxT2OUxJXtDnD1RMDAdJZHZ3gRuiRwzSsp6xvd9RRoBYLwI1QQSlgpCbBjVABAXVIp4RSdpfQBUBFS0wK9v4U-q2GwOXqNlzbbOPhRZR9GHBzOncXLeNjhpwmE0Rv1FXqLt8mPO6zwS-i9wXc-DYfcTTDs8aq3eqLGnqMTp_pkL_52hrbr1eviodw83z8ubjelJgJyWVccTMVbpoWWdE6E0xyYUkxWzlAwYJiQhAKTLecOpJ3YvLYt0Y4LBYLN0NXvr44hpWhds49-UPGzIdD8ZGn-ZWHfWxNVvw</recordid><startdate>20241115</startdate><enddate>20241115</enddate><creator>Jarošová, Johanka</creator><creator>Vyskočil, Vlastimil</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-9465-3931</orcidid></search><sort><creationdate>20241115</creationdate><title>Voltammetric Determination of the Drug Metronidazole Using a Solid Bismuth Drop Electrode</title><author>Jarošová, Johanka ; Vyskočil, Vlastimil</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c160t-9450d45b3c6c72816fc503aa374fd20d0d36712037b55f07e6c789eb1cf56a063</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jarošová, Johanka</creatorcontrib><creatorcontrib>Vyskočil, Vlastimil</creatorcontrib><collection>CrossRef</collection><jtitle>Chemické listy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jarošová, Johanka</au><au>Vyskočil, Vlastimil</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Voltammetric Determination of the Drug Metronidazole Using a Solid Bismuth Drop Electrode</atitle><jtitle>Chemické listy</jtitle><date>2024-11-15</date><risdate>2024</risdate><volume>118</volume><issue>11</issue><spage>615</spage><epage>624</epage><pages>615-624</pages><issn>0009-2770</issn><eissn>1213-7103</eissn><abstract>Solid bismuth drop electrode (SBiDE) is a new working electrode commercially available on the Czech market since 2020 by the company Metrohm. The aim of this work was to verify the applicability of SBiDE for the voltammetric determination of a model organic substance representing electrochemically reducible biologically active compounds, namely, the drug metronidazole (an antibiotic used to treat diseases caused by both Gram-positive and Gram-negative anaerobic bacteria). To the best of our knowledge, this is the very first published research work using SBiDE. Under optimum conditions (Britton-Robinson buffer of pH 12.0 was used as the supporting electrolyte and the working electrode surface was not electrochemically regenerated), a linear calibration dependence of metronidazole was obtained using differential pulse voltammetry (DPV) in the concentration range from 1 to 600 μmol L–1, with the limits of detection (LOD) and quantification (LOQ) of 0.41 μmol L–1 and 1.4 μmol L–1, respectively. Cyclic voltammetry (CV) on SBiDE was used to characterize the electrode process of the irreversible reduction of metronidazole. The newly developed DPV method was also successfully applied for the determination of metronidazole in authentic drinking water samples (LOD = 1.8 μmol L−1 and LOQ = 5.8 μmol L−1) and in various dosage forms (UV-Vis spectrophotometry was used as a comparative analytical method).
Full text English translation is available in the on-line version.</abstract><doi>10.54779/chl20240615</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0001-9465-3931</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-2770 |
ispartof | Chemické listy, 2024-11, Vol.118 (11), p.615-624 |
issn | 0009-2770 1213-7103 |
language | eng |
recordid | cdi_crossref_primary_10_54779_chl20240615 |
source | Full-Text Journals in Chemistry (Open access); Elektronische Zeitschriftenbibliothek; Alma/SFX Local Collection |
title | Voltammetric Determination of the Drug Metronidazole Using a Solid Bismuth Drop Electrode |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T19%3A28%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Voltammetric%20Determination%20of%20the%20Drug%20Metronidazole%20Using%20a%20Solid%20Bismuth%20Drop%20Electrode&rft.jtitle=Chemick%C3%A9%20listy&rft.au=Jaro%C5%A1ov%C3%A1,%20Johanka&rft.date=2024-11-15&rft.volume=118&rft.issue=11&rft.spage=615&rft.epage=624&rft.pages=615-624&rft.issn=0009-2770&rft.eissn=1213-7103&rft_id=info:doi/10.54779/chl20240615&rft_dat=%3Ccrossref%3E10_54779_chl20240615%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |