Laboratory-Based Investigation of Contactors Susceptibility to Short Duration Voltage Sags

Voltage sags pose substantial challenges in electrical systems, disrupting power supply and adversely impacting equipment. This paper outlines the issues arising from voltage sags, emphasizing their detrimental effects on electrical installations powered by relays and contactors. The study delves in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RE&PQJ 2024-07, p.154-159
Hauptverfasser: A. Fioravanti, A. Credo, E. Fiorucci, S. Mari, A. Prudenzi, A. Silvestri
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 159
container_issue
container_start_page 154
container_title RE&PQJ
container_volume
creator A. Fioravanti
A. Credo
E. Fiorucci
S. Mari
A. Prudenzi
A. Silvestri
description Voltage sags pose substantial challenges in electrical systems, disrupting power supply and adversely impacting equipment. This paper outlines the issues arising from voltage sags, emphasizing their detrimental effects on electrical installations powered by relays and contactors. The study delves into the susceptibility of these critical components when faced with voltage fluctuations, exploring how sags influence their functionality. Additionally, the research presents experimental results from laboratory tests, focusing on contactors of different power exposed to voltage sags lasting less than one cycle. These assessments provide insights into the performance of contactors under short-duration voltage variations, offering valuable contributions to enhancing the reliability of electrical systems.
doi_str_mv 10.52152/3934
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_52152_3934</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_52152_3934</sourcerecordid><originalsourceid>FETCH-LOGICAL-c614-f6deda1a1d9c83aabdacb404d2ec9c210ff985d2cf881d6df3ed0f3ceffa85f03</originalsourceid><addsrcrecordid>eNpNkEtLxDAURoMoOIz9D9m4rObR1nSp9TEDBRcdRNyU2yS3BmozJBmh_97HuHD1fYvDWRxCMs6uSsFLcS1rWZyQleA3ImdSvZ7---cki9ENrKgqoXgtVuSthcEHSD4s-R1Ea-h2_rQxuRGS8zP1SBs_J9DfRKTdIWq7T25wk0sLTZ527z4ken8IR_zFTwlGSzsY4wU5Q5iizf52TXaPD7tmk7fPT9vmts11xYscK2MNcOCm1koCDAb0ULDCCKtrLThDrFVphEaluKkMSmsYSm0RQZXI5JpcHrU6-BiDxX4f3AeEpees_03S_ySRXzOBVi4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Laboratory-Based Investigation of Contactors Susceptibility to Short Duration Voltage Sags</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>A. Fioravanti ; A. Credo ; E. Fiorucci ; S. Mari ; A. Prudenzi ; A. Silvestri</creator><creatorcontrib>A. Fioravanti ; A. Credo ; E. Fiorucci ; S. Mari ; A. Prudenzi ; A. Silvestri</creatorcontrib><description>Voltage sags pose substantial challenges in electrical systems, disrupting power supply and adversely impacting equipment. This paper outlines the issues arising from voltage sags, emphasizing their detrimental effects on electrical installations powered by relays and contactors. The study delves into the susceptibility of these critical components when faced with voltage fluctuations, exploring how sags influence their functionality. Additionally, the research presents experimental results from laboratory tests, focusing on contactors of different power exposed to voltage sags lasting less than one cycle. These assessments provide insights into the performance of contactors under short-duration voltage variations, offering valuable contributions to enhancing the reliability of electrical systems.</description><identifier>ISSN: 2172-038X</identifier><identifier>EISSN: 2172-038X</identifier><identifier>DOI: 10.52152/3934</identifier><language>eng</language><ispartof>RE&amp;PQJ, 2024-07, p.154-159</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>A. Fioravanti</creatorcontrib><creatorcontrib>A. Credo</creatorcontrib><creatorcontrib>E. Fiorucci</creatorcontrib><creatorcontrib>S. Mari</creatorcontrib><creatorcontrib>A. Prudenzi</creatorcontrib><creatorcontrib>A. Silvestri</creatorcontrib><title>Laboratory-Based Investigation of Contactors Susceptibility to Short Duration Voltage Sags</title><title>RE&amp;PQJ</title><description>Voltage sags pose substantial challenges in electrical systems, disrupting power supply and adversely impacting equipment. This paper outlines the issues arising from voltage sags, emphasizing their detrimental effects on electrical installations powered by relays and contactors. The study delves into the susceptibility of these critical components when faced with voltage fluctuations, exploring how sags influence their functionality. Additionally, the research presents experimental results from laboratory tests, focusing on contactors of different power exposed to voltage sags lasting less than one cycle. These assessments provide insights into the performance of contactors under short-duration voltage variations, offering valuable contributions to enhancing the reliability of electrical systems.</description><issn>2172-038X</issn><issn>2172-038X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpNkEtLxDAURoMoOIz9D9m4rObR1nSp9TEDBRcdRNyU2yS3BmozJBmh_97HuHD1fYvDWRxCMs6uSsFLcS1rWZyQleA3ImdSvZ7---cki9ENrKgqoXgtVuSthcEHSD4s-R1Ea-h2_rQxuRGS8zP1SBs_J9DfRKTdIWq7T25wk0sLTZ527z4ken8IR_zFTwlGSzsY4wU5Q5iizf52TXaPD7tmk7fPT9vmts11xYscK2MNcOCm1koCDAb0ULDCCKtrLThDrFVphEaluKkMSmsYSm0RQZXI5JpcHrU6-BiDxX4f3AeEpees_03S_ySRXzOBVi4</recordid><startdate>20240723</startdate><enddate>20240723</enddate><creator>A. Fioravanti</creator><creator>A. Credo</creator><creator>E. Fiorucci</creator><creator>S. Mari</creator><creator>A. Prudenzi</creator><creator>A. Silvestri</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20240723</creationdate><title>Laboratory-Based Investigation of Contactors Susceptibility to Short Duration Voltage Sags</title><author>A. Fioravanti ; A. Credo ; E. Fiorucci ; S. Mari ; A. Prudenzi ; A. Silvestri</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c614-f6deda1a1d9c83aabdacb404d2ec9c210ff985d2cf881d6df3ed0f3ceffa85f03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>online_resources</toplevel><creatorcontrib>A. Fioravanti</creatorcontrib><creatorcontrib>A. Credo</creatorcontrib><creatorcontrib>E. Fiorucci</creatorcontrib><creatorcontrib>S. Mari</creatorcontrib><creatorcontrib>A. Prudenzi</creatorcontrib><creatorcontrib>A. Silvestri</creatorcontrib><collection>CrossRef</collection><jtitle>RE&amp;PQJ</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>A. Fioravanti</au><au>A. Credo</au><au>E. Fiorucci</au><au>S. Mari</au><au>A. Prudenzi</au><au>A. Silvestri</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Laboratory-Based Investigation of Contactors Susceptibility to Short Duration Voltage Sags</atitle><jtitle>RE&amp;PQJ</jtitle><date>2024-07-23</date><risdate>2024</risdate><spage>154</spage><epage>159</epage><pages>154-159</pages><issn>2172-038X</issn><eissn>2172-038X</eissn><abstract>Voltage sags pose substantial challenges in electrical systems, disrupting power supply and adversely impacting equipment. This paper outlines the issues arising from voltage sags, emphasizing their detrimental effects on electrical installations powered by relays and contactors. The study delves into the susceptibility of these critical components when faced with voltage fluctuations, exploring how sags influence their functionality. Additionally, the research presents experimental results from laboratory tests, focusing on contactors of different power exposed to voltage sags lasting less than one cycle. These assessments provide insights into the performance of contactors under short-duration voltage variations, offering valuable contributions to enhancing the reliability of electrical systems.</abstract><doi>10.52152/3934</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2172-038X
ispartof RE&PQJ, 2024-07, p.154-159
issn 2172-038X
2172-038X
language eng
recordid cdi_crossref_primary_10_52152_3934
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
title Laboratory-Based Investigation of Contactors Susceptibility to Short Duration Voltage Sags
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T14%3A00%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Laboratory-Based%20Investigation%20of%20Contactors%20Susceptibility%20to%20Short%20Duration%20Voltage%20Sags&rft.jtitle=RE&PQJ&rft.au=A.%20Fioravanti&rft.date=2024-07-23&rft.spage=154&rft.epage=159&rft.pages=154-159&rft.issn=2172-038X&rft.eissn=2172-038X&rft_id=info:doi/10.52152/3934&rft_dat=%3Ccrossref%3E10_52152_3934%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true