Calculation Algorithm of Three-dimensional Absorbed Dose Distribution in Non-water Equivalent Tissue Due to Administration of Radio-labeled Antibody
In radioimmunotherapy, an algorithm is proposed for the purpose of calculating three-dimensional absorbed dose distributions of non-water equivalent tissues. The three-dimensional absorbed dose distribution due to the algorithm, is given by convolution of the threedimensional dose matrix for a unit...
Gespeichert in:
Veröffentlicht in: | RADIOISOTOPES 1994/07/15, Vol.43(7), pp.397-404 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng ; jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 404 |
---|---|
container_issue | 7 |
container_start_page | 397 |
container_title | RADIOISOTOPES |
container_volume | 43 |
creator | UCHIDA, Isao YAMADA, Yasuhiko OYAMADA, Hiyoshimaru YAMASHITA, Takashi ITO, Akira |
description | In radioimmunotherapy, an algorithm is proposed for the purpose of calculating three-dimensional absorbed dose distributions of non-water equivalent tissues. The three-dimensional absorbed dose distribution due to the algorithm, is given by convolution of the threedimensional dose matrix for a unit cubic voxel containing unit cumulated activity, with the three-dimensional matrix of the cumulated activity distribution given by the same voxel size above. The three-dimensional dose matrix for the unit voxel source, is calculated from the β- or photon-dose point kernel in the corresponding tissue. Present work theoretically showed that β- and photon-dose point kernels in non-water equivalent tissue can be calculated by applying a scaling factor on distance to each dose point kernel in water. In consequence, present calculation algorithm is essentially the same as the algorithm for water that authors have already developed. Computer simulations were performed using the MIRD lung phantom, and the agreement obtained between the results of present work and the MIRD method, supported the validity of the proposed calculation algorithm. |
doi_str_mv | 10.3769/radioisotopes.43.397 |
format | Article |
fullrecord | <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_3769_radioisotopes_43_397</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_radioisotopes1952_43_7_43_7_397_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2187-d3a1e8fcc7320e162988b8337678fcc4f20445bd6ad209eb1b1b50506441a03e3</originalsourceid><addsrcrecordid>eNpVkNtOwzAMhiMEEmPwBlzkBTqSJj1dVts4SAMkNK6rpHW3TGkzkgy09-CBSSmahCzbku3Ptn6EbimZsSwt7qxolFHOeLMHN-NsxorsDE1onvOIU0rP0YQQxqKcEXaJrpzbERKnCckm6HsudH3QwivT41JvjFV-22HT4vXWAkSN6qB3oSk0LqUzVkKDF8YBXijnrZKHX1L1-MX00ZfwYPHy46A-hYbe47Vy7hBmg3uDy6ZT_YCN58KRt-HzSAsJOuwte6-kaY7X6KIV2sHNX56i9_vlev4YrV4fnublKqpjmmdRwwSFvK3rjMUEaBoXeS5zFiTJhipvY8J5IptUNDEpQNJgCUlIyjkVhAGbIj7ura1xzkJb7a3qhD1WlFSDstU_ZSvOqqBswJ5HbOe82MAJEtarWsN_iBZJPIDZGAJ_mqu3wlbQsx87eJA4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Calculation Algorithm of Three-dimensional Absorbed Dose Distribution in Non-water Equivalent Tissue Due to Administration of Radio-labeled Antibody</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Free Full-Text Journals in Chemistry</source><creator>UCHIDA, Isao ; YAMADA, Yasuhiko ; OYAMADA, Hiyoshimaru ; YAMASHITA, Takashi ; ITO, Akira</creator><creatorcontrib>UCHIDA, Isao ; YAMADA, Yasuhiko ; OYAMADA, Hiyoshimaru ; YAMASHITA, Takashi ; ITO, Akira</creatorcontrib><description>In radioimmunotherapy, an algorithm is proposed for the purpose of calculating three-dimensional absorbed dose distributions of non-water equivalent tissues. The three-dimensional absorbed dose distribution due to the algorithm, is given by convolution of the threedimensional dose matrix for a unit cubic voxel containing unit cumulated activity, with the three-dimensional matrix of the cumulated activity distribution given by the same voxel size above. The three-dimensional dose matrix for the unit voxel source, is calculated from the β- or photon-dose point kernel in the corresponding tissue. Present work theoretically showed that β- and photon-dose point kernels in non-water equivalent tissue can be calculated by applying a scaling factor on distance to each dose point kernel in water. In consequence, present calculation algorithm is essentially the same as the algorithm for water that authors have already developed. Computer simulations were performed using the MIRD lung phantom, and the agreement obtained between the results of present work and the MIRD method, supported the validity of the proposed calculation algorithm.</description><identifier>ISSN: 0033-8303</identifier><identifier>EISSN: 1884-4111</identifier><identifier>DOI: 10.3769/radioisotopes.43.397</identifier><language>eng ; jpn</language><publisher>Japan Radioisotope Association</publisher><subject>calculation algorithm ; dose point kernel ; non-water equivalent tissue ; radio-labeled monoclonal antibody ; radioimmunotherapy ; three-dimensional absorbed dose distribution</subject><ispartof>RADIOISOTOPES, 1994/07/15, Vol.43(7), pp.397-404</ispartof><rights>Japan Radioisotope Association</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1882,4023,27922,27923,27924</link.rule.ids></links><search><creatorcontrib>UCHIDA, Isao</creatorcontrib><creatorcontrib>YAMADA, Yasuhiko</creatorcontrib><creatorcontrib>OYAMADA, Hiyoshimaru</creatorcontrib><creatorcontrib>YAMASHITA, Takashi</creatorcontrib><creatorcontrib>ITO, Akira</creatorcontrib><title>Calculation Algorithm of Three-dimensional Absorbed Dose Distribution in Non-water Equivalent Tissue Due to Administration of Radio-labeled Antibody</title><title>RADIOISOTOPES</title><description>In radioimmunotherapy, an algorithm is proposed for the purpose of calculating three-dimensional absorbed dose distributions of non-water equivalent tissues. The three-dimensional absorbed dose distribution due to the algorithm, is given by convolution of the threedimensional dose matrix for a unit cubic voxel containing unit cumulated activity, with the three-dimensional matrix of the cumulated activity distribution given by the same voxel size above. The three-dimensional dose matrix for the unit voxel source, is calculated from the β- or photon-dose point kernel in the corresponding tissue. Present work theoretically showed that β- and photon-dose point kernels in non-water equivalent tissue can be calculated by applying a scaling factor on distance to each dose point kernel in water. In consequence, present calculation algorithm is essentially the same as the algorithm for water that authors have already developed. Computer simulations were performed using the MIRD lung phantom, and the agreement obtained between the results of present work and the MIRD method, supported the validity of the proposed calculation algorithm.</description><subject>calculation algorithm</subject><subject>dose point kernel</subject><subject>non-water equivalent tissue</subject><subject>radio-labeled monoclonal antibody</subject><subject>radioimmunotherapy</subject><subject>three-dimensional absorbed dose distribution</subject><issn>0033-8303</issn><issn>1884-4111</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNpVkNtOwzAMhiMEEmPwBlzkBTqSJj1dVts4SAMkNK6rpHW3TGkzkgy09-CBSSmahCzbku3Ptn6EbimZsSwt7qxolFHOeLMHN-NsxorsDE1onvOIU0rP0YQQxqKcEXaJrpzbERKnCckm6HsudH3QwivT41JvjFV-22HT4vXWAkSN6qB3oSk0LqUzVkKDF8YBXijnrZKHX1L1-MX00ZfwYPHy46A-hYbe47Vy7hBmg3uDy6ZT_YCN58KRt-HzSAsJOuwte6-kaY7X6KIV2sHNX56i9_vlev4YrV4fnublKqpjmmdRwwSFvK3rjMUEaBoXeS5zFiTJhipvY8J5IptUNDEpQNJgCUlIyjkVhAGbIj7ura1xzkJb7a3qhD1WlFSDstU_ZSvOqqBswJ5HbOe82MAJEtarWsN_iBZJPIDZGAJ_mqu3wlbQsx87eJA4</recordid><startdate>1994</startdate><enddate>1994</enddate><creator>UCHIDA, Isao</creator><creator>YAMADA, Yasuhiko</creator><creator>OYAMADA, Hiyoshimaru</creator><creator>YAMASHITA, Takashi</creator><creator>ITO, Akira</creator><general>Japan Radioisotope Association</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1994</creationdate><title>Calculation Algorithm of Three-dimensional Absorbed Dose Distribution in Non-water Equivalent Tissue Due to Administration of Radio-labeled Antibody</title><author>UCHIDA, Isao ; YAMADA, Yasuhiko ; OYAMADA, Hiyoshimaru ; YAMASHITA, Takashi ; ITO, Akira</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2187-d3a1e8fcc7320e162988b8337678fcc4f20445bd6ad209eb1b1b50506441a03e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>1994</creationdate><topic>calculation algorithm</topic><topic>dose point kernel</topic><topic>non-water equivalent tissue</topic><topic>radio-labeled monoclonal antibody</topic><topic>radioimmunotherapy</topic><topic>three-dimensional absorbed dose distribution</topic><toplevel>online_resources</toplevel><creatorcontrib>UCHIDA, Isao</creatorcontrib><creatorcontrib>YAMADA, Yasuhiko</creatorcontrib><creatorcontrib>OYAMADA, Hiyoshimaru</creatorcontrib><creatorcontrib>YAMASHITA, Takashi</creatorcontrib><creatorcontrib>ITO, Akira</creatorcontrib><collection>CrossRef</collection><jtitle>RADIOISOTOPES</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>UCHIDA, Isao</au><au>YAMADA, Yasuhiko</au><au>OYAMADA, Hiyoshimaru</au><au>YAMASHITA, Takashi</au><au>ITO, Akira</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calculation Algorithm of Three-dimensional Absorbed Dose Distribution in Non-water Equivalent Tissue Due to Administration of Radio-labeled Antibody</atitle><jtitle>RADIOISOTOPES</jtitle><date>1994</date><risdate>1994</risdate><volume>43</volume><issue>7</issue><spage>397</spage><epage>404</epage><pages>397-404</pages><issn>0033-8303</issn><eissn>1884-4111</eissn><abstract>In radioimmunotherapy, an algorithm is proposed for the purpose of calculating three-dimensional absorbed dose distributions of non-water equivalent tissues. The three-dimensional absorbed dose distribution due to the algorithm, is given by convolution of the threedimensional dose matrix for a unit cubic voxel containing unit cumulated activity, with the three-dimensional matrix of the cumulated activity distribution given by the same voxel size above. The three-dimensional dose matrix for the unit voxel source, is calculated from the β- or photon-dose point kernel in the corresponding tissue. Present work theoretically showed that β- and photon-dose point kernels in non-water equivalent tissue can be calculated by applying a scaling factor on distance to each dose point kernel in water. In consequence, present calculation algorithm is essentially the same as the algorithm for water that authors have already developed. Computer simulations were performed using the MIRD lung phantom, and the agreement obtained between the results of present work and the MIRD method, supported the validity of the proposed calculation algorithm.</abstract><pub>Japan Radioisotope Association</pub><doi>10.3769/radioisotopes.43.397</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0033-8303 |
ispartof | RADIOISOTOPES, 1994/07/15, Vol.43(7), pp.397-404 |
issn | 0033-8303 1884-4111 |
language | eng ; jpn |
recordid | cdi_crossref_primary_10_3769_radioisotopes_43_397 |
source | J-STAGE Free; EZB-FREE-00999 freely available EZB journals; Free Full-Text Journals in Chemistry |
subjects | calculation algorithm dose point kernel non-water equivalent tissue radio-labeled monoclonal antibody radioimmunotherapy three-dimensional absorbed dose distribution |
title | Calculation Algorithm of Three-dimensional Absorbed Dose Distribution in Non-water Equivalent Tissue Due to Administration of Radio-labeled Antibody |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T14%3A35%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calculation%20Algorithm%20of%20Three-dimensional%20Absorbed%20Dose%20Distribution%20in%20Non-water%20Equivalent%20Tissue%20Due%20to%20Administration%20of%20Radio-labeled%20Antibody&rft.jtitle=RADIOISOTOPES&rft.au=UCHIDA,%20Isao&rft.date=1994&rft.volume=43&rft.issue=7&rft.spage=397&rft.epage=404&rft.pages=397-404&rft.issn=0033-8303&rft.eissn=1884-4111&rft_id=info:doi/10.3769/radioisotopes.43.397&rft_dat=%3Cjstage_cross%3Earticle_radioisotopes1952_43_7_43_7_397_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |