MVO-PS Optimized Hybrid FOFPID Controller for Load Frequency Control of an AC Micro-Grid System

This paper proposes a new approach for load frequency control in a multi micro grid system by using hybrid multi verse with pattern search (hMVO-PS) algorithm based Fractional Order Fuzzy PID controller. A multi micro grid system may be molded by some of the renewable resources (RESs) like photovolt...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of recent technology and engineering 2019-07, Vol.8 (2), p.3805-3812
Hauptverfasser: Nayak, P.C., Patel, S., Prusty, R.C., Panda, S.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3812
container_issue 2
container_start_page 3805
container_title International journal of recent technology and engineering
container_volume 8
creator Nayak, P.C.
Patel, S.
Prusty, R.C.
Panda, S.
description This paper proposes a new approach for load frequency control in a multi micro grid system by using hybrid multi verse with pattern search (hMVO-PS) algorithm based Fractional Order Fuzzy PID controller. A multi micro grid system may be molded by some of the renewable resources (RESs) like photovoltaic (PVs), wind (WTGs), energy storage system (ESSs) and loads. The fractional order fuzzy PID (FOFPID) controller parameters are optimized by novel hybrid Multi verse with pattern search (hMVO-PS) technique. The flexibility and robustness of proposed FOFPID controller is inspected under different disturbance like stochastic variations. The superiority of FOFPID structure over conventional Fuzzy PID/PID and hMVO-PS technique over multi verse optimization (MVO), particle swarm optimization (PSO) and genetic algorithm (GA) has been manifested.
doi_str_mv 10.35940/ijrte.B2254.078219
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_35940_ijrte_B2254_078219</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_35940_ijrte_B2254_078219</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2099-29b0b972a8235745d9822966634edc56d04f5830d37c3368867bd41fc99127013</originalsourceid><addsrcrecordid>eNpNkEtLw0AAhBdRsNT-Ai_7BzbuK_s41mjaQkoKVa9Lkt1ASh51Ew_x15umCp5mYGCG-QB4JDhgoeb4qTr5wQXPlIY8wFJRom_AglIpEVNS3f7z92DV9yeMMWGCcCYWwOw_UnQ4wvQ8VE317SzcjrmvLIzT-LB7gVHXDr6ra-dh2XmYdNkUeff55dpi_EthV8KshesI7qvCd2hzKTiO_eCaB3BXZnXvVr-6BO_x61u0RUm62UXrBBUUa42oznGuJc0UZaHkodWKUi2EYNzZIhQW8zJUDFsmC8aEUkLmlpOy0JpQOd1ZAnbtnfb73rvSnH3VZH40BJsZk5kxmRmTuWJiPzmZWZQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>MVO-PS Optimized Hybrid FOFPID Controller for Load Frequency Control of an AC Micro-Grid System</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Nayak, P.C. ; Patel, S. ; Prusty, R.C. ; Panda, S.</creator><creatorcontrib>Nayak, P.C. ; Patel, S. ; Prusty, R.C. ; Panda, S. ; Professor, Electrical Engineering Department, VSSUT, Burla, Odisha, India ; M.Tech Scholar, Electrical Engineering Department, VSSUT, Burla, Odisha, India ; Asst. Professor, Electrical Engineering Department, VSSUT, Burla, Odisha, India ; Ph.D. Scholar, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><description>This paper proposes a new approach for load frequency control in a multi micro grid system by using hybrid multi verse with pattern search (hMVO-PS) algorithm based Fractional Order Fuzzy PID controller. A multi micro grid system may be molded by some of the renewable resources (RESs) like photovoltaic (PVs), wind (WTGs), energy storage system (ESSs) and loads. The fractional order fuzzy PID (FOFPID) controller parameters are optimized by novel hybrid Multi verse with pattern search (hMVO-PS) technique. The flexibility and robustness of proposed FOFPID controller is inspected under different disturbance like stochastic variations. The superiority of FOFPID structure over conventional Fuzzy PID/PID and hMVO-PS technique over multi verse optimization (MVO), particle swarm optimization (PSO) and genetic algorithm (GA) has been manifested.</description><identifier>ISSN: 2277-3878</identifier><identifier>EISSN: 2277-3878</identifier><identifier>DOI: 10.35940/ijrte.B2254.078219</identifier><language>eng</language><ispartof>International journal of recent technology and engineering, 2019-07, Vol.8 (2), p.3805-3812</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2099-29b0b972a8235745d9822966634edc56d04f5830d37c3368867bd41fc99127013</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Nayak, P.C.</creatorcontrib><creatorcontrib>Patel, S.</creatorcontrib><creatorcontrib>Prusty, R.C.</creatorcontrib><creatorcontrib>Panda, S.</creatorcontrib><creatorcontrib>Professor, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><creatorcontrib>M.Tech Scholar, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><creatorcontrib>Asst. Professor, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><creatorcontrib>Ph.D. Scholar, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><title>MVO-PS Optimized Hybrid FOFPID Controller for Load Frequency Control of an AC Micro-Grid System</title><title>International journal of recent technology and engineering</title><description>This paper proposes a new approach for load frequency control in a multi micro grid system by using hybrid multi verse with pattern search (hMVO-PS) algorithm based Fractional Order Fuzzy PID controller. A multi micro grid system may be molded by some of the renewable resources (RESs) like photovoltaic (PVs), wind (WTGs), energy storage system (ESSs) and loads. The fractional order fuzzy PID (FOFPID) controller parameters are optimized by novel hybrid Multi verse with pattern search (hMVO-PS) technique. The flexibility and robustness of proposed FOFPID controller is inspected under different disturbance like stochastic variations. The superiority of FOFPID structure over conventional Fuzzy PID/PID and hMVO-PS technique over multi verse optimization (MVO), particle swarm optimization (PSO) and genetic algorithm (GA) has been manifested.</description><issn>2277-3878</issn><issn>2277-3878</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpNkEtLw0AAhBdRsNT-Ai_7BzbuK_s41mjaQkoKVa9Lkt1ASh51Ew_x15umCp5mYGCG-QB4JDhgoeb4qTr5wQXPlIY8wFJRom_AglIpEVNS3f7z92DV9yeMMWGCcCYWwOw_UnQ4wvQ8VE317SzcjrmvLIzT-LB7gVHXDr6ra-dh2XmYdNkUeff55dpi_EthV8KshesI7qvCd2hzKTiO_eCaB3BXZnXvVr-6BO_x61u0RUm62UXrBBUUa42oznGuJc0UZaHkodWKUi2EYNzZIhQW8zJUDFsmC8aEUkLmlpOy0JpQOd1ZAnbtnfb73rvSnH3VZH40BJsZk5kxmRmTuWJiPzmZWZQ</recordid><startdate>20190730</startdate><enddate>20190730</enddate><creator>Nayak, P.C.</creator><creator>Patel, S.</creator><creator>Prusty, R.C.</creator><creator>Panda, S.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20190730</creationdate><title>MVO-PS Optimized Hybrid FOFPID Controller for Load Frequency Control of an AC Micro-Grid System</title><author>Nayak, P.C. ; Patel, S. ; Prusty, R.C. ; Panda, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2099-29b0b972a8235745d9822966634edc56d04f5830d37c3368867bd41fc99127013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Nayak, P.C.</creatorcontrib><creatorcontrib>Patel, S.</creatorcontrib><creatorcontrib>Prusty, R.C.</creatorcontrib><creatorcontrib>Panda, S.</creatorcontrib><creatorcontrib>Professor, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><creatorcontrib>M.Tech Scholar, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><creatorcontrib>Asst. Professor, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><creatorcontrib>Ph.D. Scholar, Electrical Engineering Department, VSSUT, Burla, Odisha, India</creatorcontrib><collection>CrossRef</collection><jtitle>International journal of recent technology and engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nayak, P.C.</au><au>Patel, S.</au><au>Prusty, R.C.</au><au>Panda, S.</au><aucorp>Professor, Electrical Engineering Department, VSSUT, Burla, Odisha, India</aucorp><aucorp>M.Tech Scholar, Electrical Engineering Department, VSSUT, Burla, Odisha, India</aucorp><aucorp>Asst. Professor, Electrical Engineering Department, VSSUT, Burla, Odisha, India</aucorp><aucorp>Ph.D. Scholar, Electrical Engineering Department, VSSUT, Burla, Odisha, India</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>MVO-PS Optimized Hybrid FOFPID Controller for Load Frequency Control of an AC Micro-Grid System</atitle><jtitle>International journal of recent technology and engineering</jtitle><date>2019-07-30</date><risdate>2019</risdate><volume>8</volume><issue>2</issue><spage>3805</spage><epage>3812</epage><pages>3805-3812</pages><issn>2277-3878</issn><eissn>2277-3878</eissn><abstract>This paper proposes a new approach for load frequency control in a multi micro grid system by using hybrid multi verse with pattern search (hMVO-PS) algorithm based Fractional Order Fuzzy PID controller. A multi micro grid system may be molded by some of the renewable resources (RESs) like photovoltaic (PVs), wind (WTGs), energy storage system (ESSs) and loads. The fractional order fuzzy PID (FOFPID) controller parameters are optimized by novel hybrid Multi verse with pattern search (hMVO-PS) technique. The flexibility and robustness of proposed FOFPID controller is inspected under different disturbance like stochastic variations. The superiority of FOFPID structure over conventional Fuzzy PID/PID and hMVO-PS technique over multi verse optimization (MVO), particle swarm optimization (PSO) and genetic algorithm (GA) has been manifested.</abstract><doi>10.35940/ijrte.B2254.078219</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2277-3878
ispartof International journal of recent technology and engineering, 2019-07, Vol.8 (2), p.3805-3812
issn 2277-3878
2277-3878
language eng
recordid cdi_crossref_primary_10_35940_ijrte_B2254_078219
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
title MVO-PS Optimized Hybrid FOFPID Controller for Load Frequency Control of an AC Micro-Grid System
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T18%3A06%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=MVO-PS%20Optimized%20Hybrid%20FOFPID%20Controller%20for%20Load%20Frequency%20Control%20of%20an%20AC%20Micro-Grid%20System&rft.jtitle=International%20journal%20of%20recent%20technology%20and%20engineering&rft.au=Nayak,%20P.C.&rft.aucorp=Professor,%20Electrical%20Engineering%20Department,%20VSSUT,%20Burla,%20Odisha,%20India&rft.date=2019-07-30&rft.volume=8&rft.issue=2&rft.spage=3805&rft.epage=3812&rft.pages=3805-3812&rft.issn=2277-3878&rft.eissn=2277-3878&rft_id=info:doi/10.35940/ijrte.B2254.078219&rft_dat=%3Ccrossref%3E10_35940_ijrte_B2254_078219%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true