Design and Development of an IoT-based Pulmonary Function and Oxygen Saturation Measurement Device

Health information technology plays a crucial role in managing the healthcare of patients and their families during illness. One of the frequently encountered diseases is Asthma, a chronic inflammatory disorder of the respiratory tract that is reversible and fluctuating, capable of causing exacerbat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Electromedical Engineering, and Medical Informatics, 2024-02, Vol.6 (1), p.34-42
Hauptverfasser: Lutfiyah, Sari, Yuwana, Rahmadika Eka, Ariswati, Her Gumiwang
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 42
container_issue 1
container_start_page 34
container_title Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
container_volume 6
creator Lutfiyah, Sari
Yuwana, Rahmadika Eka
Ariswati, Her Gumiwang
description Health information technology plays a crucial role in managing the healthcare of patients and their families during illness. One of the frequently encountered diseases is Asthma, a chronic inflammatory disorder of the respiratory tract that is reversible and fluctuating, capable of causing exacerbations with mild to severe symptoms and even death. The objective of this research is to develop a device to facilitate the monitoring and input of data regarding pulmonary volume measurements (spirometry) and biosignals (SpO2). The sensors used for measuring pulmonary volume are the flow turbine sensor, while the SpO2 sensor used is the MAX30102. The data obtained from the sensor measurements will be processed on the ESP32. A health monitoring application is created using Kodular software, which incorporates a MySQL database for data storage. Furthermore, the examination results can be accessed through an Android application on a tablet or smartphone. The results obtained from this research indicate an error value of 8.78% for FVC, 14% for FEV1, and a FEV1/FVC ratio of 4.6%, with zero data loss. It is expected that the spirometer with Internet of Things (IoT) capabilities will be implemented, as monitoring can be easily conducted anywhere. The portable design will facilitate future examinations.
doi_str_mv 10.35882/ijeeemi.v6i1.310
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_35882_ijeeemi_v6i1_310</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_35882_ijeeemi_v6i1_310</sourcerecordid><originalsourceid>FETCH-LOGICAL-c850-21992ce63228dc3e73869e5459ffb57d3c5b0adc0cd4667271341e31e70b6adb3</originalsourceid><addsrcrecordid>eNpNkM1Kw0AUhQdRsNQ-gLt5gcT5yfxkKa3VQqWC2YfJzE2ZkmRKpin27Y1pF67O5cD9OHwIPVOScqE1e_EHAGh9epaeppySOzRjUshES5bd_7sf0SLGAyGE6ZxrpWaoWkH0-w6bzuEVnKEJxxa6Ew71WOFNKJLKRHD4a2ja0Jn-gtdDZ08-XF92P5c9dPjbnIbeTO0nmDj0MEFGoLfwhB5q00RY3HKOivVbsfxItrv3zfJ1m1gtSMJonjMLkjOmneWguJY5iEzkdV0J5bgVFTHOEusyKRVTlGcUOAVFKmlcxeeIXrG2DzH2UJfH3rfj4pKSctJU3jSVf5rKURP_BdVMXog</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Design and Development of an IoT-based Pulmonary Function and Oxygen Saturation Measurement Device</title><source>Alma/SFX Local Collection</source><creator>Lutfiyah, Sari ; Yuwana, Rahmadika Eka ; Ariswati, Her Gumiwang</creator><creatorcontrib>Lutfiyah, Sari ; Yuwana, Rahmadika Eka ; Ariswati, Her Gumiwang</creatorcontrib><description>Health information technology plays a crucial role in managing the healthcare of patients and their families during illness. One of the frequently encountered diseases is Asthma, a chronic inflammatory disorder of the respiratory tract that is reversible and fluctuating, capable of causing exacerbations with mild to severe symptoms and even death. The objective of this research is to develop a device to facilitate the monitoring and input of data regarding pulmonary volume measurements (spirometry) and biosignals (SpO2). The sensors used for measuring pulmonary volume are the flow turbine sensor, while the SpO2 sensor used is the MAX30102. The data obtained from the sensor measurements will be processed on the ESP32. A health monitoring application is created using Kodular software, which incorporates a MySQL database for data storage. Furthermore, the examination results can be accessed through an Android application on a tablet or smartphone. The results obtained from this research indicate an error value of 8.78% for FVC, 14% for FEV1, and a FEV1/FVC ratio of 4.6%, with zero data loss. It is expected that the spirometer with Internet of Things (IoT) capabilities will be implemented, as monitoring can be easily conducted anywhere. The portable design will facilitate future examinations.</description><identifier>ISSN: 2656-8624</identifier><identifier>EISSN: 2656-8624</identifier><identifier>DOI: 10.35882/ijeeemi.v6i1.310</identifier><language>eng</language><ispartof>Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, 2024-02, Vol.6 (1), p.34-42</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Lutfiyah, Sari</creatorcontrib><creatorcontrib>Yuwana, Rahmadika Eka</creatorcontrib><creatorcontrib>Ariswati, Her Gumiwang</creatorcontrib><title>Design and Development of an IoT-based Pulmonary Function and Oxygen Saturation Measurement Device</title><title>Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics</title><description>Health information technology plays a crucial role in managing the healthcare of patients and their families during illness. One of the frequently encountered diseases is Asthma, a chronic inflammatory disorder of the respiratory tract that is reversible and fluctuating, capable of causing exacerbations with mild to severe symptoms and even death. The objective of this research is to develop a device to facilitate the monitoring and input of data regarding pulmonary volume measurements (spirometry) and biosignals (SpO2). The sensors used for measuring pulmonary volume are the flow turbine sensor, while the SpO2 sensor used is the MAX30102. The data obtained from the sensor measurements will be processed on the ESP32. A health monitoring application is created using Kodular software, which incorporates a MySQL database for data storage. Furthermore, the examination results can be accessed through an Android application on a tablet or smartphone. The results obtained from this research indicate an error value of 8.78% for FVC, 14% for FEV1, and a FEV1/FVC ratio of 4.6%, with zero data loss. It is expected that the spirometer with Internet of Things (IoT) capabilities will be implemented, as monitoring can be easily conducted anywhere. The portable design will facilitate future examinations.</description><issn>2656-8624</issn><issn>2656-8624</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpNkM1Kw0AUhQdRsNQ-gLt5gcT5yfxkKa3VQqWC2YfJzE2ZkmRKpin27Y1pF67O5cD9OHwIPVOScqE1e_EHAGh9epaeppySOzRjUshES5bd_7sf0SLGAyGE6ZxrpWaoWkH0-w6bzuEVnKEJxxa6Ew71WOFNKJLKRHD4a2ja0Jn-gtdDZ08-XF92P5c9dPjbnIbeTO0nmDj0MEFGoLfwhB5q00RY3HKOivVbsfxItrv3zfJ1m1gtSMJonjMLkjOmneWguJY5iEzkdV0J5bgVFTHOEusyKRVTlGcUOAVFKmlcxeeIXrG2DzH2UJfH3rfj4pKSctJU3jSVf5rKURP_BdVMXog</recordid><startdate>20240208</startdate><enddate>20240208</enddate><creator>Lutfiyah, Sari</creator><creator>Yuwana, Rahmadika Eka</creator><creator>Ariswati, Her Gumiwang</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20240208</creationdate><title>Design and Development of an IoT-based Pulmonary Function and Oxygen Saturation Measurement Device</title><author>Lutfiyah, Sari ; Yuwana, Rahmadika Eka ; Ariswati, Her Gumiwang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c850-21992ce63228dc3e73869e5459ffb57d3c5b0adc0cd4667271341e31e70b6adb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Lutfiyah, Sari</creatorcontrib><creatorcontrib>Yuwana, Rahmadika Eka</creatorcontrib><creatorcontrib>Ariswati, Her Gumiwang</creatorcontrib><collection>CrossRef</collection><jtitle>Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lutfiyah, Sari</au><au>Yuwana, Rahmadika Eka</au><au>Ariswati, Her Gumiwang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and Development of an IoT-based Pulmonary Function and Oxygen Saturation Measurement Device</atitle><jtitle>Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics</jtitle><date>2024-02-08</date><risdate>2024</risdate><volume>6</volume><issue>1</issue><spage>34</spage><epage>42</epage><pages>34-42</pages><issn>2656-8624</issn><eissn>2656-8624</eissn><abstract>Health information technology plays a crucial role in managing the healthcare of patients and their families during illness. One of the frequently encountered diseases is Asthma, a chronic inflammatory disorder of the respiratory tract that is reversible and fluctuating, capable of causing exacerbations with mild to severe symptoms and even death. The objective of this research is to develop a device to facilitate the monitoring and input of data regarding pulmonary volume measurements (spirometry) and biosignals (SpO2). The sensors used for measuring pulmonary volume are the flow turbine sensor, while the SpO2 sensor used is the MAX30102. The data obtained from the sensor measurements will be processed on the ESP32. A health monitoring application is created using Kodular software, which incorporates a MySQL database for data storage. Furthermore, the examination results can be accessed through an Android application on a tablet or smartphone. The results obtained from this research indicate an error value of 8.78% for FVC, 14% for FEV1, and a FEV1/FVC ratio of 4.6%, with zero data loss. It is expected that the spirometer with Internet of Things (IoT) capabilities will be implemented, as monitoring can be easily conducted anywhere. The portable design will facilitate future examinations.</abstract><doi>10.35882/ijeeemi.v6i1.310</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2656-8624
ispartof Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, 2024-02, Vol.6 (1), p.34-42
issn 2656-8624
2656-8624
language eng
recordid cdi_crossref_primary_10_35882_ijeeemi_v6i1_310
source Alma/SFX Local Collection
title Design and Development of an IoT-based Pulmonary Function and Oxygen Saturation Measurement Device
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T19%3A11%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20Development%20of%20an%20IoT-based%20Pulmonary%20Function%20and%20Oxygen%20Saturation%20Measurement%20Device&rft.jtitle=Indonesian%20Journal%20of%20Electronics,%20Electromedical%20Engineering,%20and%20Medical%20Informatics&rft.au=Lutfiyah,%20Sari&rft.date=2024-02-08&rft.volume=6&rft.issue=1&rft.spage=34&rft.epage=42&rft.pages=34-42&rft.issn=2656-8624&rft.eissn=2656-8624&rft_id=info:doi/10.35882/ijeeemi.v6i1.310&rft_dat=%3Ccrossref%3E10_35882_ijeeemi_v6i1_310%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true