Immunological analysis of pesticides: a new tool in groundwater testing

Groundwater is the major source of drinking water in many European countries, and in Denmark alone it accounts for more than 99% of the drinking water supply. Within the past decade pesticide residues have frequently been detected in groundwater, in many cases at levels exceeding the 0.1 µg/l limit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:GEUS Bulletin 2004, Vol.4, p.29-32
Hauptverfasser: Aamand, Jens, Bruun, Leif, Vöge Christensen, Bo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 32
container_issue
container_start_page 29
container_title GEUS Bulletin
container_volume 4
creator Aamand, Jens
Bruun, Leif
Vöge Christensen, Bo
description Groundwater is the major source of drinking water in many European countries, and in Denmark alone it accounts for more than 99% of the drinking water supply. Within the past decade pesticide residues have frequently been detected in groundwater, in many cases at levels exceeding the 0.1 µg/l limit set by the European Community. As a consequence, drinking water abstraction wells have had to be closed in many places in Denmark and other European countries, and a vast amount of money is expended to monitor groundwater pesticide levels. A degradation product of the herbicide dichlobenil, 2,6-dichlorobenzamide (BAM), is the most common cause of drinking water well closure in Denmark. Triazines and their metabolites also contaminate groundwater in many countries, and pose a similar risk to the drinking water supply. Analysis of most pesticides and their degradation products is usually carried out by concentrating the samples by solvent extraction, and identifying the contaminants using gas chromatography (GC) or high-pressure liquid chromatography (HPLC) combined with mass spectrometry (MS). These methods, although robust and well established, are very time-consuming and require specialised instrumentation. The large quantity of solvents used is another draw back to these methods, as the solvents themselves may be carcinogenic and are also well known contaminants of groundwater. The development of cheap, more sensitive and more rapid pesticide assays is therefore urgent. Due to their very high sensitivity, immunological methods have long been used in biological science for analysing a large variety of organic structures, but have only recently been introduced to environmental analysis. The benefit of such assays is primarily their high sensitivity, which allows the analysis to be undertaken without the need to concentrate the samples, but also the facility of dealing with large numbers of samples. Compared to conventional analyses, immunological methods face two major drawbacks – one related to specificity and the other to the fact that only very few chemicals can currently be analysed simultaneously. The crux of the specificity problem is that although antibodies react very specifically with particular chemical structures, these same structures may be present in analogous compounds. Thus antibodies developed to recognise, for example the herbicide atrazine might also recognise other triazines (Bruun et al. 2001). An important scientific challenge is therefore
doi_str_mv 10.34194/geusb.v4.4776
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_34194_geusb_v4_4776</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2585830280</sourcerecordid><originalsourceid>FETCH-LOGICAL-a203t-c9591d07b7c8087658e626276757c987342998b93b50371dd7dc3d37cc0c65f93</originalsourceid><addsrcrecordid>eNotkM1LwzAYxoMoOOaungOeW_P94U2GzsHAi55DmqSl0jYzaTf239ttnp7n8ON9H34APGJUUoY1e27ClKvywEompbgBCywQKxTm4nbueu5MCHEPVjm3FSJCSyQIXYDNtu-nIXaxaZ3toB1sd8pthrGG-5DH1rU-5Bdo4RCOcIyxg-0AmxSnwR_tGBIcz9TQPIC72nY5rP5zCb7f377WH8Xuc7Ndv-4KSxAdC6e5xh7JSjqFlBRcBUEEkUJy6bSSlBGtVaVpxRGV2HvpHfVUOoec4LWmS_B0vbtP8Xeaf5ufOKV5dTaEK64oIgrNVHmlXIo5p1CbfWp7m04GI3PxZS6-zIGZsy_6B4v-Xk0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2585830280</pqid></control><display><type>article</type><title>Immunological analysis of pesticides: a new tool in groundwater testing</title><source>DOAJ Directory of Open Access Journals</source><creator>Aamand, Jens ; Bruun, Leif ; Vöge Christensen, Bo</creator><creatorcontrib>Aamand, Jens ; Bruun, Leif ; Vöge Christensen, Bo</creatorcontrib><description>Groundwater is the major source of drinking water in many European countries, and in Denmark alone it accounts for more than 99% of the drinking water supply. Within the past decade pesticide residues have frequently been detected in groundwater, in many cases at levels exceeding the 0.1 µg/l limit set by the European Community. As a consequence, drinking water abstraction wells have had to be closed in many places in Denmark and other European countries, and a vast amount of money is expended to monitor groundwater pesticide levels. A degradation product of the herbicide dichlobenil, 2,6-dichlorobenzamide (BAM), is the most common cause of drinking water well closure in Denmark. Triazines and their metabolites also contaminate groundwater in many countries, and pose a similar risk to the drinking water supply. Analysis of most pesticides and their degradation products is usually carried out by concentrating the samples by solvent extraction, and identifying the contaminants using gas chromatography (GC) or high-pressure liquid chromatography (HPLC) combined with mass spectrometry (MS). These methods, although robust and well established, are very time-consuming and require specialised instrumentation. The large quantity of solvents used is another draw back to these methods, as the solvents themselves may be carcinogenic and are also well known contaminants of groundwater. The development of cheap, more sensitive and more rapid pesticide assays is therefore urgent. Due to their very high sensitivity, immunological methods have long been used in biological science for analysing a large variety of organic structures, but have only recently been introduced to environmental analysis. The benefit of such assays is primarily their high sensitivity, which allows the analysis to be undertaken without the need to concentrate the samples, but also the facility of dealing with large numbers of samples. Compared to conventional analyses, immunological methods face two major drawbacks – one related to specificity and the other to the fact that only very few chemicals can currently be analysed simultaneously. The crux of the specificity problem is that although antibodies react very specifically with particular chemical structures, these same structures may be present in analogous compounds. Thus antibodies developed to recognise, for example the herbicide atrazine might also recognise other triazines (Bruun et al. 2001). An important scientific challenge is therefore the development of highly specific assays recognising each individual compound, as well as assays recognising groups of related chemicals. With respect to the simultaneous analysis of numerous chemicals, this can be resolved by implementing the new biochip technology, which incorporates the parallellity of sample screening. On a pesticide biochip many specific immunological assays are carried out in isolated small spots on a glass or polymer surface. Each spot has a size of approximately 150 micrometers and forms a specific analysis. Such a miniaturised platform will be usable for monitoring programmes where water samples have to be screened for a range of chemical contaminants. The overall objectives of this study have been (1) to develop immunoassays for high-sensitivity analysis of specific pesticides and chemically related groups of pesticides, and (2) to transfer the developed assays to a miniaturised biochip platform in a manner allowing analysis of several pesticides simultaneously.</description><identifier>ISSN: 1904-4666</identifier><identifier>EISSN: 1604-8156</identifier><identifier>EISSN: 2597-2154</identifier><identifier>DOI: 10.34194/geusb.v4.4776</identifier><language>eng</language><publisher>Copenhagen: De Nationale Geologiske Undersoegelser for Danmark og Groenland / Geological Survey of Denmark and Greenland</publisher><subject>Atrazine ; Chemical contaminants ; Chemical pollution ; Chemicals ; Chromatography ; Contaminants ; Degradation products ; Drinking water ; Gas chromatography ; Groundwater ; Herbicides ; Immunoassays ; Immunology ; Instrumentation ; Liquid chromatography ; Mass spectrometry ; Metabolites ; Pesticide residues ; Pesticides ; Pollution monitoring ; Polymers ; Sensitivity analysis ; Solvent extraction ; Solvents ; Water analysis ; Water sampling ; Water supply ; Water wells</subject><ispartof>GEUS Bulletin, 2004, Vol.4, p.29-32</ispartof><rights>2004. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a203t-c9591d07b7c8087658e626276757c987342998b93b50371dd7dc3d37cc0c65f93</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,4022,27922,27923,27924</link.rule.ids></links><search><creatorcontrib>Aamand, Jens</creatorcontrib><creatorcontrib>Bruun, Leif</creatorcontrib><creatorcontrib>Vöge Christensen, Bo</creatorcontrib><title>Immunological analysis of pesticides: a new tool in groundwater testing</title><title>GEUS Bulletin</title><description>Groundwater is the major source of drinking water in many European countries, and in Denmark alone it accounts for more than 99% of the drinking water supply. Within the past decade pesticide residues have frequently been detected in groundwater, in many cases at levels exceeding the 0.1 µg/l limit set by the European Community. As a consequence, drinking water abstraction wells have had to be closed in many places in Denmark and other European countries, and a vast amount of money is expended to monitor groundwater pesticide levels. A degradation product of the herbicide dichlobenil, 2,6-dichlorobenzamide (BAM), is the most common cause of drinking water well closure in Denmark. Triazines and their metabolites also contaminate groundwater in many countries, and pose a similar risk to the drinking water supply. Analysis of most pesticides and their degradation products is usually carried out by concentrating the samples by solvent extraction, and identifying the contaminants using gas chromatography (GC) or high-pressure liquid chromatography (HPLC) combined with mass spectrometry (MS). These methods, although robust and well established, are very time-consuming and require specialised instrumentation. The large quantity of solvents used is another draw back to these methods, as the solvents themselves may be carcinogenic and are also well known contaminants of groundwater. The development of cheap, more sensitive and more rapid pesticide assays is therefore urgent. Due to their very high sensitivity, immunological methods have long been used in biological science for analysing a large variety of organic structures, but have only recently been introduced to environmental analysis. The benefit of such assays is primarily their high sensitivity, which allows the analysis to be undertaken without the need to concentrate the samples, but also the facility of dealing with large numbers of samples. Compared to conventional analyses, immunological methods face two major drawbacks – one related to specificity and the other to the fact that only very few chemicals can currently be analysed simultaneously. The crux of the specificity problem is that although antibodies react very specifically with particular chemical structures, these same structures may be present in analogous compounds. Thus antibodies developed to recognise, for example the herbicide atrazine might also recognise other triazines (Bruun et al. 2001). An important scientific challenge is therefore the development of highly specific assays recognising each individual compound, as well as assays recognising groups of related chemicals. With respect to the simultaneous analysis of numerous chemicals, this can be resolved by implementing the new biochip technology, which incorporates the parallellity of sample screening. On a pesticide biochip many specific immunological assays are carried out in isolated small spots on a glass or polymer surface. Each spot has a size of approximately 150 micrometers and forms a specific analysis. Such a miniaturised platform will be usable for monitoring programmes where water samples have to be screened for a range of chemical contaminants. The overall objectives of this study have been (1) to develop immunoassays for high-sensitivity analysis of specific pesticides and chemically related groups of pesticides, and (2) to transfer the developed assays to a miniaturised biochip platform in a manner allowing analysis of several pesticides simultaneously.</description><subject>Atrazine</subject><subject>Chemical contaminants</subject><subject>Chemical pollution</subject><subject>Chemicals</subject><subject>Chromatography</subject><subject>Contaminants</subject><subject>Degradation products</subject><subject>Drinking water</subject><subject>Gas chromatography</subject><subject>Groundwater</subject><subject>Herbicides</subject><subject>Immunoassays</subject><subject>Immunology</subject><subject>Instrumentation</subject><subject>Liquid chromatography</subject><subject>Mass spectrometry</subject><subject>Metabolites</subject><subject>Pesticide residues</subject><subject>Pesticides</subject><subject>Pollution monitoring</subject><subject>Polymers</subject><subject>Sensitivity analysis</subject><subject>Solvent extraction</subject><subject>Solvents</subject><subject>Water analysis</subject><subject>Water sampling</subject><subject>Water supply</subject><subject>Water wells</subject><issn>1904-4666</issn><issn>1604-8156</issn><issn>2597-2154</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNotkM1LwzAYxoMoOOaungOeW_P94U2GzsHAi55DmqSl0jYzaTf239ttnp7n8ON9H34APGJUUoY1e27ClKvywEompbgBCywQKxTm4nbueu5MCHEPVjm3FSJCSyQIXYDNtu-nIXaxaZ3toB1sd8pthrGG-5DH1rU-5Bdo4RCOcIyxg-0AmxSnwR_tGBIcz9TQPIC72nY5rP5zCb7f377WH8Xuc7Ndv-4KSxAdC6e5xh7JSjqFlBRcBUEEkUJy6bSSlBGtVaVpxRGV2HvpHfVUOoec4LWmS_B0vbtP8Xeaf5ufOKV5dTaEK64oIgrNVHmlXIo5p1CbfWp7m04GI3PxZS6-zIGZsy_6B4v-Xk0</recordid><startdate>2004</startdate><enddate>2004</enddate><creator>Aamand, Jens</creator><creator>Bruun, Leif</creator><creator>Vöge Christensen, Bo</creator><general>De Nationale Geologiske Undersoegelser for Danmark og Groenland / Geological Survey of Denmark and Greenland</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>BKSAR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>PCBAR</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>2004</creationdate><title>Immunological analysis of pesticides: a new tool in groundwater testing</title><author>Aamand, Jens ; Bruun, Leif ; Vöge Christensen, Bo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a203t-c9591d07b7c8087658e626276757c987342998b93b50371dd7dc3d37cc0c65f93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Atrazine</topic><topic>Chemical contaminants</topic><topic>Chemical pollution</topic><topic>Chemicals</topic><topic>Chromatography</topic><topic>Contaminants</topic><topic>Degradation products</topic><topic>Drinking water</topic><topic>Gas chromatography</topic><topic>Groundwater</topic><topic>Herbicides</topic><topic>Immunoassays</topic><topic>Immunology</topic><topic>Instrumentation</topic><topic>Liquid chromatography</topic><topic>Mass spectrometry</topic><topic>Metabolites</topic><topic>Pesticide residues</topic><topic>Pesticides</topic><topic>Pollution monitoring</topic><topic>Polymers</topic><topic>Sensitivity analysis</topic><topic>Solvent extraction</topic><topic>Solvents</topic><topic>Water analysis</topic><topic>Water sampling</topic><topic>Water supply</topic><topic>Water wells</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aamand, Jens</creatorcontrib><creatorcontrib>Bruun, Leif</creatorcontrib><creatorcontrib>Vöge Christensen, Bo</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest Earth, Atmospheric &amp; Aquatic Science</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection (Proquest) (PQ_SDU_P3)</collection><collection>Earth, Atmospheric &amp; Aquatic Science Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>GEUS Bulletin</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aamand, Jens</au><au>Bruun, Leif</au><au>Vöge Christensen, Bo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Immunological analysis of pesticides: a new tool in groundwater testing</atitle><jtitle>GEUS Bulletin</jtitle><date>2004</date><risdate>2004</risdate><volume>4</volume><spage>29</spage><epage>32</epage><pages>29-32</pages><issn>1904-4666</issn><eissn>1604-8156</eissn><eissn>2597-2154</eissn><abstract>Groundwater is the major source of drinking water in many European countries, and in Denmark alone it accounts for more than 99% of the drinking water supply. Within the past decade pesticide residues have frequently been detected in groundwater, in many cases at levels exceeding the 0.1 µg/l limit set by the European Community. As a consequence, drinking water abstraction wells have had to be closed in many places in Denmark and other European countries, and a vast amount of money is expended to monitor groundwater pesticide levels. A degradation product of the herbicide dichlobenil, 2,6-dichlorobenzamide (BAM), is the most common cause of drinking water well closure in Denmark. Triazines and their metabolites also contaminate groundwater in many countries, and pose a similar risk to the drinking water supply. Analysis of most pesticides and their degradation products is usually carried out by concentrating the samples by solvent extraction, and identifying the contaminants using gas chromatography (GC) or high-pressure liquid chromatography (HPLC) combined with mass spectrometry (MS). These methods, although robust and well established, are very time-consuming and require specialised instrumentation. The large quantity of solvents used is another draw back to these methods, as the solvents themselves may be carcinogenic and are also well known contaminants of groundwater. The development of cheap, more sensitive and more rapid pesticide assays is therefore urgent. Due to their very high sensitivity, immunological methods have long been used in biological science for analysing a large variety of organic structures, but have only recently been introduced to environmental analysis. The benefit of such assays is primarily their high sensitivity, which allows the analysis to be undertaken without the need to concentrate the samples, but also the facility of dealing with large numbers of samples. Compared to conventional analyses, immunological methods face two major drawbacks – one related to specificity and the other to the fact that only very few chemicals can currently be analysed simultaneously. The crux of the specificity problem is that although antibodies react very specifically with particular chemical structures, these same structures may be present in analogous compounds. Thus antibodies developed to recognise, for example the herbicide atrazine might also recognise other triazines (Bruun et al. 2001). An important scientific challenge is therefore the development of highly specific assays recognising each individual compound, as well as assays recognising groups of related chemicals. With respect to the simultaneous analysis of numerous chemicals, this can be resolved by implementing the new biochip technology, which incorporates the parallellity of sample screening. On a pesticide biochip many specific immunological assays are carried out in isolated small spots on a glass or polymer surface. Each spot has a size of approximately 150 micrometers and forms a specific analysis. Such a miniaturised platform will be usable for monitoring programmes where water samples have to be screened for a range of chemical contaminants. The overall objectives of this study have been (1) to develop immunoassays for high-sensitivity analysis of specific pesticides and chemically related groups of pesticides, and (2) to transfer the developed assays to a miniaturised biochip platform in a manner allowing analysis of several pesticides simultaneously.</abstract><cop>Copenhagen</cop><pub>De Nationale Geologiske Undersoegelser for Danmark og Groenland / Geological Survey of Denmark and Greenland</pub><doi>10.34194/geusb.v4.4776</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1904-4666
ispartof GEUS Bulletin, 2004, Vol.4, p.29-32
issn 1904-4666
1604-8156
2597-2154
language eng
recordid cdi_crossref_primary_10_34194_geusb_v4_4776
source DOAJ Directory of Open Access Journals
subjects Atrazine
Chemical contaminants
Chemical pollution
Chemicals
Chromatography
Contaminants
Degradation products
Drinking water
Gas chromatography
Groundwater
Herbicides
Immunoassays
Immunology
Instrumentation
Liquid chromatography
Mass spectrometry
Metabolites
Pesticide residues
Pesticides
Pollution monitoring
Polymers
Sensitivity analysis
Solvent extraction
Solvents
Water analysis
Water sampling
Water supply
Water wells
title Immunological analysis of pesticides: a new tool in groundwater testing
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T14%3A49%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Immunological%20analysis%20of%20pesticides:%20a%20new%20tool%20in%20groundwater%20testing&rft.jtitle=GEUS%20Bulletin&rft.au=Aamand,%20Jens&rft.date=2004&rft.volume=4&rft.spage=29&rft.epage=32&rft.pages=29-32&rft.issn=1904-4666&rft.eissn=1604-8156&rft_id=info:doi/10.34194/geusb.v4.4776&rft_dat=%3Cproquest_cross%3E2585830280%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2585830280&rft_id=info:pmid/&rfr_iscdi=true