Determination of azoxystrobin in tea by HPLC

A determination method has been developed for azoxystrobin in tea by HPLC. Azoxystrobin was extracted from a sample with acetone, and the extract was passed through an alumina column to remove tannin. The eluate was concentrated to ca. 25mL and passed through a Sep-Pak Vac tC18 to remove pigments. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi) 2001/08/25, Vol.42(4), pp.249-251
1. Verfasser: Chonan, T. (Hokkaido. Inst. of Public Health, Sapporo (Japan))
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A determination method has been developed for azoxystrobin in tea by HPLC. Azoxystrobin was extracted from a sample with acetone, and the extract was passed through an alumina column to remove tannin. The eluate was concentrated to ca. 25mL and passed through a Sep-Pak Vac tC18 to remove pigments. The eluate was cleaned-up by using liquid-liquid partition, and Florisil and silica-gel columns. The HPLC analysis for azoxystrobin was carried out on a C18 column with acetonitrile-water (9:11) as the mobile phase, with ultraviolet detection at 260nm. The recovery of azoxystrobin fortified at the level of 0.4 micro g/g was 90.2% and the limit of determination was 0.2 micro g/g.