A Simple and Rapid Analytical Method for Nicotinic Acid and Nicotinamide in Meat by Using Niacin Test Paper

A simple and rapid method for the quantitative determination of nicotinic acid (NA) and nicotinamide (NAA) in meat was developed. Five grams of meat was placed in a beaker, 10ml of distilled water was added and mixed, and the beaker was placed in a boiling water bath for 5min. The mixture was filter...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi) 1989/04/05, Vol.30(2), pp.175-178_1
Hauptverfasser: TAKAHASHI, Mayumi, SUZUKI, Hitoshi, MINAMI, Masako, HAKUDA, Tadao, KOSEKI, Mari, KANNO, Shuichiro, KUBOTA, Yoko, HARADA, Mieko, TEZUKA, Tomohiko
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 178_1
container_issue 2
container_start_page 175
container_title Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)
container_volume 30
creator TAKAHASHI, Mayumi
SUZUKI, Hitoshi
MINAMI, Masako
HAKUDA, Tadao
KOSEKI, Mari
KANNO, Shuichiro
KUBOTA, Yoko
HARADA, Mieko
TEZUKA, Tomohiko
description A simple and rapid method for the quantitative determination of nicotinic acid (NA) and nicotinamide (NAA) in meat was developed. Five grams of meat was placed in a beaker, 10ml of distilled water was added and mixed, and the beaker was placed in a boiling water bath for 5min. The mixture was filtered, after cooling with water. The filtrate was put in a 10ml tube and niacin test paper (NTP) was added. When NA or NAA had been added to the meat, the color of NTP changed to orange, and quantitation was done by comparison with standard colors. According to the results of market research, NA and NAA are added at levels of more than 100mg/kg to meat. Therefore, it is possible to judge by means of the NTP method whether NA or NAA has been added to meat or not.
doi_str_mv 10.3358/shokueishi.30.175
format Article
fullrecord <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_3358_shokueishi_30_175</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_shokueishi1960_30_2_30_2_175_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c364t-ae6af85b0d92ebf893bcc1461dbfd0fdcab320d63fe02eb352380f96beb3c97f3</originalsourceid><addsrcrecordid>eNpNkMtOwzAQRS0EEqXwAez8AynjuHGTZVTxVHkI2nU08aNxmyaRbRb9e1wVFTbj0fU5s7iE3DKYcJ7ld77pt9_a-sZOOEzYLDsjI5bnacIAxDkZAbAsEdNUXJIr7zcxBA75iGxL-mV3Q6spdop-4mAVLTts98FKbOmrDk2vqOkdfbOyD7azkpYyQgf8N8KdVZraLtIYaL2nK2-7dfxFGcOl9oF-4KDdNbkw2Hp98_uOyerhfjl_Shbvj8_zcpFILqYhQS3Q5FkNqkh1bfKC11KyqWCqNgqMkljzFJTgRkMEeJbyHEwh6rjLYmb4mLDjXel675021eDsDt2-YlAd2qr-2qo4VLGt6LwcnY0PuNYnA10sotX_DFYIOFjpcUT5BMkGXaU7_gOVz3z7</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Simple and Rapid Analytical Method for Nicotinic Acid and Nicotinamide in Meat by Using Niacin Test Paper</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>TAKAHASHI, Mayumi ; SUZUKI, Hitoshi ; MINAMI, Masako ; HAKUDA, Tadao ; KOSEKI, Mari ; KANNO, Shuichiro ; KUBOTA, Yoko ; HARADA, Mieko ; TEZUKA, Tomohiko</creator><creatorcontrib>TAKAHASHI, Mayumi ; SUZUKI, Hitoshi ; MINAMI, Masako ; HAKUDA, Tadao ; KOSEKI, Mari ; KANNO, Shuichiro ; KUBOTA, Yoko ; HARADA, Mieko ; TEZUKA, Tomohiko</creatorcontrib><description>A simple and rapid method for the quantitative determination of nicotinic acid (NA) and nicotinamide (NAA) in meat was developed. Five grams of meat was placed in a beaker, 10ml of distilled water was added and mixed, and the beaker was placed in a boiling water bath for 5min. The mixture was filtered, after cooling with water. The filtrate was put in a 10ml tube and niacin test paper (NTP) was added. When NA or NAA had been added to the meat, the color of NTP changed to orange, and quantitation was done by comparison with standard colors. According to the results of market research, NA and NAA are added at levels of more than 100mg/kg to meat. Therefore, it is possible to judge by means of the NTP method whether NA or NAA has been added to meat or not.</description><identifier>ISSN: 0015-6426</identifier><identifier>EISSN: 1882-1006</identifier><identifier>DOI: 10.3358/shokueishi.30.175</identifier><language>eng ; jpn</language><publisher>Japanese Society for Food Hygiene and Safety</publisher><subject>meat ; niacin test paper ; nicotinamide ; nicotinic acid</subject><ispartof>Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi), 1989/04/05, Vol.30(2), pp.175-178_1</ispartof><rights>The Food Hygienic Society of Japan</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>TAKAHASHI, Mayumi</creatorcontrib><creatorcontrib>SUZUKI, Hitoshi</creatorcontrib><creatorcontrib>MINAMI, Masako</creatorcontrib><creatorcontrib>HAKUDA, Tadao</creatorcontrib><creatorcontrib>KOSEKI, Mari</creatorcontrib><creatorcontrib>KANNO, Shuichiro</creatorcontrib><creatorcontrib>KUBOTA, Yoko</creatorcontrib><creatorcontrib>HARADA, Mieko</creatorcontrib><creatorcontrib>TEZUKA, Tomohiko</creatorcontrib><title>A Simple and Rapid Analytical Method for Nicotinic Acid and Nicotinamide in Meat by Using Niacin Test Paper</title><title>Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)</title><addtitle>Food Hyg. Saf. Sci.</addtitle><description>A simple and rapid method for the quantitative determination of nicotinic acid (NA) and nicotinamide (NAA) in meat was developed. Five grams of meat was placed in a beaker, 10ml of distilled water was added and mixed, and the beaker was placed in a boiling water bath for 5min. The mixture was filtered, after cooling with water. The filtrate was put in a 10ml tube and niacin test paper (NTP) was added. When NA or NAA had been added to the meat, the color of NTP changed to orange, and quantitation was done by comparison with standard colors. According to the results of market research, NA and NAA are added at levels of more than 100mg/kg to meat. Therefore, it is possible to judge by means of the NTP method whether NA or NAA has been added to meat or not.</description><subject>meat</subject><subject>niacin test paper</subject><subject>nicotinamide</subject><subject>nicotinic acid</subject><issn>0015-6426</issn><issn>1882-1006</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><recordid>eNpNkMtOwzAQRS0EEqXwAez8AynjuHGTZVTxVHkI2nU08aNxmyaRbRb9e1wVFTbj0fU5s7iE3DKYcJ7ld77pt9_a-sZOOEzYLDsjI5bnacIAxDkZAbAsEdNUXJIr7zcxBA75iGxL-mV3Q6spdop-4mAVLTts98FKbOmrDk2vqOkdfbOyD7azkpYyQgf8N8KdVZraLtIYaL2nK2-7dfxFGcOl9oF-4KDdNbkw2Hp98_uOyerhfjl_Shbvj8_zcpFILqYhQS3Q5FkNqkh1bfKC11KyqWCqNgqMkljzFJTgRkMEeJbyHEwh6rjLYmb4mLDjXel675021eDsDt2-YlAd2qr-2qo4VLGt6LwcnY0PuNYnA10sotX_DFYIOFjpcUT5BMkGXaU7_gOVz3z7</recordid><startdate>1989</startdate><enddate>1989</enddate><creator>TAKAHASHI, Mayumi</creator><creator>SUZUKI, Hitoshi</creator><creator>MINAMI, Masako</creator><creator>HAKUDA, Tadao</creator><creator>KOSEKI, Mari</creator><creator>KANNO, Shuichiro</creator><creator>KUBOTA, Yoko</creator><creator>HARADA, Mieko</creator><creator>TEZUKA, Tomohiko</creator><general>Japanese Society for Food Hygiene and Safety</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1989</creationdate><title>A Simple and Rapid Analytical Method for Nicotinic Acid and Nicotinamide in Meat by Using Niacin Test Paper</title><author>TAKAHASHI, Mayumi ; SUZUKI, Hitoshi ; MINAMI, Masako ; HAKUDA, Tadao ; KOSEKI, Mari ; KANNO, Shuichiro ; KUBOTA, Yoko ; HARADA, Mieko ; TEZUKA, Tomohiko</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c364t-ae6af85b0d92ebf893bcc1461dbfd0fdcab320d63fe02eb352380f96beb3c97f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>1989</creationdate><topic>meat</topic><topic>niacin test paper</topic><topic>nicotinamide</topic><topic>nicotinic acid</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>TAKAHASHI, Mayumi</creatorcontrib><creatorcontrib>SUZUKI, Hitoshi</creatorcontrib><creatorcontrib>MINAMI, Masako</creatorcontrib><creatorcontrib>HAKUDA, Tadao</creatorcontrib><creatorcontrib>KOSEKI, Mari</creatorcontrib><creatorcontrib>KANNO, Shuichiro</creatorcontrib><creatorcontrib>KUBOTA, Yoko</creatorcontrib><creatorcontrib>HARADA, Mieko</creatorcontrib><creatorcontrib>TEZUKA, Tomohiko</creatorcontrib><collection>CrossRef</collection><jtitle>Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>TAKAHASHI, Mayumi</au><au>SUZUKI, Hitoshi</au><au>MINAMI, Masako</au><au>HAKUDA, Tadao</au><au>KOSEKI, Mari</au><au>KANNO, Shuichiro</au><au>KUBOTA, Yoko</au><au>HARADA, Mieko</au><au>TEZUKA, Tomohiko</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Simple and Rapid Analytical Method for Nicotinic Acid and Nicotinamide in Meat by Using Niacin Test Paper</atitle><jtitle>Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)</jtitle><addtitle>Food Hyg. Saf. Sci.</addtitle><date>1989</date><risdate>1989</risdate><volume>30</volume><issue>2</issue><spage>175</spage><epage>178_1</epage><pages>175-178_1</pages><issn>0015-6426</issn><eissn>1882-1006</eissn><abstract>A simple and rapid method for the quantitative determination of nicotinic acid (NA) and nicotinamide (NAA) in meat was developed. Five grams of meat was placed in a beaker, 10ml of distilled water was added and mixed, and the beaker was placed in a boiling water bath for 5min. The mixture was filtered, after cooling with water. The filtrate was put in a 10ml tube and niacin test paper (NTP) was added. When NA or NAA had been added to the meat, the color of NTP changed to orange, and quantitation was done by comparison with standard colors. According to the results of market research, NA and NAA are added at levels of more than 100mg/kg to meat. Therefore, it is possible to judge by means of the NTP method whether NA or NAA has been added to meat or not.</abstract><pub>Japanese Society for Food Hygiene and Safety</pub><doi>10.3358/shokueishi.30.175</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0015-6426
ispartof Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi), 1989/04/05, Vol.30(2), pp.175-178_1
issn 0015-6426
1882-1006
language eng ; jpn
recordid cdi_crossref_primary_10_3358_shokueishi_30_175
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects meat
niacin test paper
nicotinamide
nicotinic acid
title A Simple and Rapid Analytical Method for Nicotinic Acid and Nicotinamide in Meat by Using Niacin Test Paper
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T08%3A59%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Simple%20and%20Rapid%20Analytical%20Method%20for%20Nicotinic%20Acid%20and%20Nicotinamide%20in%20Meat%20by%20Using%20Niacin%20Test%20Paper&rft.jtitle=Food%20Hygiene%20and%20Safety%20Science%20(Shokuhin%20Eiseigaku%20Zasshi)&rft.au=TAKAHASHI,%20Mayumi&rft.date=1989&rft.volume=30&rft.issue=2&rft.spage=175&rft.epage=178_1&rft.pages=175-178_1&rft.issn=0015-6426&rft.eissn=1882-1006&rft_id=info:doi/10.3358/shokueishi.30.175&rft_dat=%3Cjstage_cross%3Earticle_shokueishi1960_30_2_30_2_175_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true