A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery
Abstract The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels deter...
Gespeichert in:
Veröffentlicht in: | Drug development and industrial pharmacy 1993, Vol.19 (15), p.1821-1849 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1849 |
---|---|
container_issue | 15 |
container_start_page | 1821 |
container_title | Drug development and industrial pharmacy |
container_volume | 19 |
creator | Lin, Senshang Kim, Won-Pa Chien, Yie W. |
description | Abstract
The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels determined could be higher than those in the conscious animals. Furthermore, the animals are usually excited by direct contact with the investigator during the frequent blood sampling in conscious state, which could cause the glucose level to be higher than at undisturbed state. To overcome these problems, a continuous blood glucose monitoring system was developed by connecting the sensor chamber of a glucose analyzer (YSI Industrial Analyzer model 27), which utilizes glucose oxidase for glucose measurement, to a peristaltic pump with a specially designed mixing chamber and a data acquisition station. By using this system, the hyper-/hypoglycemic activity of glucagon/insulin formulations in the conscious animals, after various routes of administration, can be determined without any interruption and/or disturbance. |
doi_str_mv | 10.3109/03639049309073893 |
format | Article |
fullrecord | <record><control><sourceid>informahealthcare_cross</sourceid><recordid>TN_cdi_crossref_primary_10_3109_03639049309073893</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_3109_03639049309073893</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-480b8000bcb519efae4c66c964c402c23a6be7af976d4670e77469ece63cf95c3</originalsourceid><addsrcrecordid>eNp9kMFKAzEQhoMoWKsP4C0Hr6vJJpts0EstWoUWD-p5yabZNmU3KUmWsm9vSlUQoaeBmf-bGT4ArjG6JRiJO0QYEYgKggTipBTkBIxwkaOs4Cw_BaP9PEuB4hxchLBBCOeiKEagnsCps9HY3vUBLpw10XljVzAMIeoONs7Dx9a5JZy1vXJBw4WWofe60zYGaCxUzgZl9vTEmk62Ae5MXLs-wvfer7QfLsFZk9r66ruOwefz08f0JZu_zV6nk3mmCOcxoyWqS4RQreoCC91ITRVjSjCqKMpVTiSrNZeN4GxJGUeac8qEVpoR1YhCkTHAh73KuxC8bqqtTw_5ocKo2kuq_klKzM2B2cqgZNt4aZUJvyAtccriFHs4xIxNQjq5c75dVlEOrfM_DDl25f4PvtayjWslva42rvc2WTny4xeqU43m</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery</title><source>Taylor & Francis Medical Library - CRKN</source><source>Access via Taylor & Francis</source><creator>Lin, Senshang ; Kim, Won-Pa ; Chien, Yie W.</creator><creatorcontrib>Lin, Senshang ; Kim, Won-Pa ; Chien, Yie W.</creatorcontrib><description>Abstract
The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels determined could be higher than those in the conscious animals. Furthermore, the animals are usually excited by direct contact with the investigator during the frequent blood sampling in conscious state, which could cause the glucose level to be higher than at undisturbed state. To overcome these problems, a continuous blood glucose monitoring system was developed by connecting the sensor chamber of a glucose analyzer (YSI Industrial Analyzer model 27), which utilizes glucose oxidase for glucose measurement, to a peristaltic pump with a specially designed mixing chamber and a data acquisition station. By using this system, the hyper-/hypoglycemic activity of glucagon/insulin formulations in the conscious animals, after various routes of administration, can be determined without any interruption and/or disturbance.</description><identifier>ISSN: 0363-9045</identifier><identifier>EISSN: 1520-5762</identifier><identifier>DOI: 10.3109/03639049309073893</identifier><language>eng</language><publisher>Colchester: Informa UK Ltd</publisher><subject>Biological and medical sciences ; General and cellular metabolism. Vitamins ; Medical sciences ; Pharmacology. Drug treatments</subject><ispartof>Drug development and industrial pharmacy, 1993, Vol.19 (15), p.1821-1849</ispartof><rights>1993 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 1993</rights><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-480b8000bcb519efae4c66c964c402c23a6be7af976d4670e77469ece63cf95c3</citedby><cites>FETCH-LOGICAL-c377t-480b8000bcb519efae4c66c964c402c23a6be7af976d4670e77469ece63cf95c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.3109/03639049309073893$$EPDF$$P50$$Ginformaworld$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.3109/03639049309073893$$EHTML$$P50$$Ginformaworld$$H</linktohtml><link.rule.ids>315,781,785,4025,27927,27928,27929,59651,59757,60440,60546,61225,61260,61406,61441</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=4813091$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Lin, Senshang</creatorcontrib><creatorcontrib>Kim, Won-Pa</creatorcontrib><creatorcontrib>Chien, Yie W.</creatorcontrib><title>A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery</title><title>Drug development and industrial pharmacy</title><description>Abstract
The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels determined could be higher than those in the conscious animals. Furthermore, the animals are usually excited by direct contact with the investigator during the frequent blood sampling in conscious state, which could cause the glucose level to be higher than at undisturbed state. To overcome these problems, a continuous blood glucose monitoring system was developed by connecting the sensor chamber of a glucose analyzer (YSI Industrial Analyzer model 27), which utilizes glucose oxidase for glucose measurement, to a peristaltic pump with a specially designed mixing chamber and a data acquisition station. By using this system, the hyper-/hypoglycemic activity of glucagon/insulin formulations in the conscious animals, after various routes of administration, can be determined without any interruption and/or disturbance.</description><subject>Biological and medical sciences</subject><subject>General and cellular metabolism. Vitamins</subject><subject>Medical sciences</subject><subject>Pharmacology. Drug treatments</subject><issn>0363-9045</issn><issn>1520-5762</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNp9kMFKAzEQhoMoWKsP4C0Hr6vJJpts0EstWoUWD-p5yabZNmU3KUmWsm9vSlUQoaeBmf-bGT4ArjG6JRiJO0QYEYgKggTipBTkBIxwkaOs4Cw_BaP9PEuB4hxchLBBCOeiKEagnsCps9HY3vUBLpw10XljVzAMIeoONs7Dx9a5JZy1vXJBw4WWofe60zYGaCxUzgZl9vTEmk62Ae5MXLs-wvfer7QfLsFZk9r66ruOwefz08f0JZu_zV6nk3mmCOcxoyWqS4RQreoCC91ITRVjSjCqKMpVTiSrNZeN4GxJGUeac8qEVpoR1YhCkTHAh73KuxC8bqqtTw_5ocKo2kuq_klKzM2B2cqgZNt4aZUJvyAtccriFHs4xIxNQjq5c75dVlEOrfM_DDl25f4PvtayjWslva42rvc2WTny4xeqU43m</recordid><startdate>1993</startdate><enddate>1993</enddate><creator>Lin, Senshang</creator><creator>Kim, Won-Pa</creator><creator>Chien, Yie W.</creator><general>Informa UK Ltd</general><general>Taylor & Francis</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1993</creationdate><title>A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery</title><author>Lin, Senshang ; Kim, Won-Pa ; Chien, Yie W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-480b8000bcb519efae4c66c964c402c23a6be7af976d4670e77469ece63cf95c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Biological and medical sciences</topic><topic>General and cellular metabolism. Vitamins</topic><topic>Medical sciences</topic><topic>Pharmacology. Drug treatments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lin, Senshang</creatorcontrib><creatorcontrib>Kim, Won-Pa</creatorcontrib><creatorcontrib>Chien, Yie W.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Drug development and industrial pharmacy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lin, Senshang</au><au>Kim, Won-Pa</au><au>Chien, Yie W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery</atitle><jtitle>Drug development and industrial pharmacy</jtitle><date>1993</date><risdate>1993</risdate><volume>19</volume><issue>15</issue><spage>1821</spage><epage>1849</epage><pages>1821-1849</pages><issn>0363-9045</issn><eissn>1520-5762</eissn><abstract>Abstract
The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels determined could be higher than those in the conscious animals. Furthermore, the animals are usually excited by direct contact with the investigator during the frequent blood sampling in conscious state, which could cause the glucose level to be higher than at undisturbed state. To overcome these problems, a continuous blood glucose monitoring system was developed by connecting the sensor chamber of a glucose analyzer (YSI Industrial Analyzer model 27), which utilizes glucose oxidase for glucose measurement, to a peristaltic pump with a specially designed mixing chamber and a data acquisition station. By using this system, the hyper-/hypoglycemic activity of glucagon/insulin formulations in the conscious animals, after various routes of administration, can be determined without any interruption and/or disturbance.</abstract><cop>Colchester</cop><pub>Informa UK Ltd</pub><doi>10.3109/03639049309073893</doi><tpages>29</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0363-9045 |
ispartof | Drug development and industrial pharmacy, 1993, Vol.19 (15), p.1821-1849 |
issn | 0363-9045 1520-5762 |
language | eng |
recordid | cdi_crossref_primary_10_3109_03639049309073893 |
source | Taylor & Francis Medical Library - CRKN; Access via Taylor & Francis |
subjects | Biological and medical sciences General and cellular metabolism. Vitamins Medical sciences Pharmacology. Drug treatments |
title | A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T00%3A53%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-informahealthcare_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Continuous%20Monitoring%20system%20for%20Blood%20Glucose%20Measurements%20in%20conscious%20Animals%20without%20Surgery&rft.jtitle=Drug%20development%20and%20industrial%20pharmacy&rft.au=Lin,%20Senshang&rft.date=1993&rft.volume=19&rft.issue=15&rft.spage=1821&rft.epage=1849&rft.pages=1821-1849&rft.issn=0363-9045&rft.eissn=1520-5762&rft_id=info:doi/10.3109/03639049309073893&rft_dat=%3Cinformahealthcare_cross%3E10_3109_03639049309073893%3C/informahealthcare_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |