A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery

Abstract The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels deter...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Drug development and industrial pharmacy 1993, Vol.19 (15), p.1821-1849
Hauptverfasser: Lin, Senshang, Kim, Won-Pa, Chien, Yie W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1849
container_issue 15
container_start_page 1821
container_title Drug development and industrial pharmacy
container_volume 19
creator Lin, Senshang
Kim, Won-Pa
Chien, Yie W.
description Abstract The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels determined could be higher than those in the conscious animals. Furthermore, the animals are usually excited by direct contact with the investigator during the frequent blood sampling in conscious state, which could cause the glucose level to be higher than at undisturbed state. To overcome these problems, a continuous blood glucose monitoring system was developed by connecting the sensor chamber of a glucose analyzer (YSI Industrial Analyzer model 27), which utilizes glucose oxidase for glucose measurement, to a peristaltic pump with a specially designed mixing chamber and a data acquisition station. By using this system, the hyper-/hypoglycemic activity of glucagon/insulin formulations in the conscious animals, after various routes of administration, can be determined without any interruption and/or disturbance.
doi_str_mv 10.3109/03639049309073893
format Article
fullrecord <record><control><sourceid>informahealthcare_cross</sourceid><recordid>TN_cdi_crossref_primary_10_3109_03639049309073893</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_3109_03639049309073893</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-480b8000bcb519efae4c66c964c402c23a6be7af976d4670e77469ece63cf95c3</originalsourceid><addsrcrecordid>eNp9kMFKAzEQhoMoWKsP4C0Hr6vJJpts0EstWoUWD-p5yabZNmU3KUmWsm9vSlUQoaeBmf-bGT4ArjG6JRiJO0QYEYgKggTipBTkBIxwkaOs4Cw_BaP9PEuB4hxchLBBCOeiKEagnsCps9HY3vUBLpw10XljVzAMIeoONs7Dx9a5JZy1vXJBw4WWofe60zYGaCxUzgZl9vTEmk62Ae5MXLs-wvfer7QfLsFZk9r66ruOwefz08f0JZu_zV6nk3mmCOcxoyWqS4RQreoCC91ITRVjSjCqKMpVTiSrNZeN4GxJGUeac8qEVpoR1YhCkTHAh73KuxC8bqqtTw_5ocKo2kuq_klKzM2B2cqgZNt4aZUJvyAtccriFHs4xIxNQjq5c75dVlEOrfM_DDl25f4PvtayjWslva42rvc2WTny4xeqU43m</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery</title><source>Taylor &amp; Francis Medical Library - CRKN</source><source>Access via Taylor &amp; Francis</source><creator>Lin, Senshang ; Kim, Won-Pa ; Chien, Yie W.</creator><creatorcontrib>Lin, Senshang ; Kim, Won-Pa ; Chien, Yie W.</creatorcontrib><description>Abstract The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels determined could be higher than those in the conscious animals. Furthermore, the animals are usually excited by direct contact with the investigator during the frequent blood sampling in conscious state, which could cause the glucose level to be higher than at undisturbed state. To overcome these problems, a continuous blood glucose monitoring system was developed by connecting the sensor chamber of a glucose analyzer (YSI Industrial Analyzer model 27), which utilizes glucose oxidase for glucose measurement, to a peristaltic pump with a specially designed mixing chamber and a data acquisition station. By using this system, the hyper-/hypoglycemic activity of glucagon/insulin formulations in the conscious animals, after various routes of administration, can be determined without any interruption and/or disturbance.</description><identifier>ISSN: 0363-9045</identifier><identifier>EISSN: 1520-5762</identifier><identifier>DOI: 10.3109/03639049309073893</identifier><language>eng</language><publisher>Colchester: Informa UK Ltd</publisher><subject>Biological and medical sciences ; General and cellular metabolism. Vitamins ; Medical sciences ; Pharmacology. Drug treatments</subject><ispartof>Drug development and industrial pharmacy, 1993, Vol.19 (15), p.1821-1849</ispartof><rights>1993 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 1993</rights><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-480b8000bcb519efae4c66c964c402c23a6be7af976d4670e77469ece63cf95c3</citedby><cites>FETCH-LOGICAL-c377t-480b8000bcb519efae4c66c964c402c23a6be7af976d4670e77469ece63cf95c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.3109/03639049309073893$$EPDF$$P50$$Ginformaworld$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.3109/03639049309073893$$EHTML$$P50$$Ginformaworld$$H</linktohtml><link.rule.ids>315,781,785,4025,27927,27928,27929,59651,59757,60440,60546,61225,61260,61406,61441</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4813091$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Lin, Senshang</creatorcontrib><creatorcontrib>Kim, Won-Pa</creatorcontrib><creatorcontrib>Chien, Yie W.</creatorcontrib><title>A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery</title><title>Drug development and industrial pharmacy</title><description>Abstract The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels determined could be higher than those in the conscious animals. Furthermore, the animals are usually excited by direct contact with the investigator during the frequent blood sampling in conscious state, which could cause the glucose level to be higher than at undisturbed state. To overcome these problems, a continuous blood glucose monitoring system was developed by connecting the sensor chamber of a glucose analyzer (YSI Industrial Analyzer model 27), which utilizes glucose oxidase for glucose measurement, to a peristaltic pump with a specially designed mixing chamber and a data acquisition station. By using this system, the hyper-/hypoglycemic activity of glucagon/insulin formulations in the conscious animals, after various routes of administration, can be determined without any interruption and/or disturbance.</description><subject>Biological and medical sciences</subject><subject>General and cellular metabolism. Vitamins</subject><subject>Medical sciences</subject><subject>Pharmacology. Drug treatments</subject><issn>0363-9045</issn><issn>1520-5762</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNp9kMFKAzEQhoMoWKsP4C0Hr6vJJpts0EstWoUWD-p5yabZNmU3KUmWsm9vSlUQoaeBmf-bGT4ArjG6JRiJO0QYEYgKggTipBTkBIxwkaOs4Cw_BaP9PEuB4hxchLBBCOeiKEagnsCps9HY3vUBLpw10XljVzAMIeoONs7Dx9a5JZy1vXJBw4WWofe60zYGaCxUzgZl9vTEmk62Ae5MXLs-wvfer7QfLsFZk9r66ruOwefz08f0JZu_zV6nk3mmCOcxoyWqS4RQreoCC91ITRVjSjCqKMpVTiSrNZeN4GxJGUeac8qEVpoR1YhCkTHAh73KuxC8bqqtTw_5ocKo2kuq_klKzM2B2cqgZNt4aZUJvyAtccriFHs4xIxNQjq5c75dVlEOrfM_DDl25f4PvtayjWslva42rvc2WTny4xeqU43m</recordid><startdate>1993</startdate><enddate>1993</enddate><creator>Lin, Senshang</creator><creator>Kim, Won-Pa</creator><creator>Chien, Yie W.</creator><general>Informa UK Ltd</general><general>Taylor &amp; Francis</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1993</creationdate><title>A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery</title><author>Lin, Senshang ; Kim, Won-Pa ; Chien, Yie W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-480b8000bcb519efae4c66c964c402c23a6be7af976d4670e77469ece63cf95c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Biological and medical sciences</topic><topic>General and cellular metabolism. Vitamins</topic><topic>Medical sciences</topic><topic>Pharmacology. Drug treatments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lin, Senshang</creatorcontrib><creatorcontrib>Kim, Won-Pa</creatorcontrib><creatorcontrib>Chien, Yie W.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Drug development and industrial pharmacy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lin, Senshang</au><au>Kim, Won-Pa</au><au>Chien, Yie W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery</atitle><jtitle>Drug development and industrial pharmacy</jtitle><date>1993</date><risdate>1993</risdate><volume>19</volume><issue>15</issue><spage>1821</spage><epage>1849</epage><pages>1821-1849</pages><issn>0363-9045</issn><eissn>1520-5762</eissn><abstract>Abstract The hypoglycemic activity of insulin delivered via the various routes is commonly determined by measuring glucose levels in the whole blood samples taken intermittently at frequent intervals. This procedure is usually performed in the anaesthetized animals, however, the glucose levels determined could be higher than those in the conscious animals. Furthermore, the animals are usually excited by direct contact with the investigator during the frequent blood sampling in conscious state, which could cause the glucose level to be higher than at undisturbed state. To overcome these problems, a continuous blood glucose monitoring system was developed by connecting the sensor chamber of a glucose analyzer (YSI Industrial Analyzer model 27), which utilizes glucose oxidase for glucose measurement, to a peristaltic pump with a specially designed mixing chamber and a data acquisition station. By using this system, the hyper-/hypoglycemic activity of glucagon/insulin formulations in the conscious animals, after various routes of administration, can be determined without any interruption and/or disturbance.</abstract><cop>Colchester</cop><pub>Informa UK Ltd</pub><doi>10.3109/03639049309073893</doi><tpages>29</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0363-9045
ispartof Drug development and industrial pharmacy, 1993, Vol.19 (15), p.1821-1849
issn 0363-9045
1520-5762
language eng
recordid cdi_crossref_primary_10_3109_03639049309073893
source Taylor & Francis Medical Library - CRKN; Access via Taylor & Francis
subjects Biological and medical sciences
General and cellular metabolism. Vitamins
Medical sciences
Pharmacology. Drug treatments
title A Continuous Monitoring system for Blood Glucose Measurements in conscious Animals without Surgery
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T00%3A53%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-informahealthcare_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Continuous%20Monitoring%20system%20for%20Blood%20Glucose%20Measurements%20in%20conscious%20Animals%20without%20Surgery&rft.jtitle=Drug%20development%20and%20industrial%20pharmacy&rft.au=Lin,%20Senshang&rft.date=1993&rft.volume=19&rft.issue=15&rft.spage=1821&rft.epage=1849&rft.pages=1821-1849&rft.issn=0363-9045&rft.eissn=1520-5762&rft_id=info:doi/10.3109/03639049309073893&rft_dat=%3Cinformahealthcare_cross%3E10_3109_03639049309073893%3C/informahealthcare_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true