Determination of criteria to find the quality of an electrical connection

A contact system is a nonredundant technical structure of electric railways that should provide uninterrupted power supply for railway vehicles. The failure of one part can lead to failure of the contact system. About 20% of damage to contact systems is due to inadmissibly high temperature at part o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Russian electrical engineering 2016-02, Vol.87 (2), p.65-67
Hauptverfasser: Ignatenko, I. V., Vlasenko, S. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 67
container_issue 2
container_start_page 65
container_title Russian electrical engineering
container_volume 87
creator Ignatenko, I. V.
Vlasenko, S. A.
description A contact system is a nonredundant technical structure of electric railways that should provide uninterrupted power supply for railway vehicles. The failure of one part can lead to failure of the contact system. About 20% of damage to contact systems is due to inadmissibly high temperature at part of an overheated catenary. In this paper, normative indices are analyzed to determine the state of the terminal under operating conditions. The existing methods of thermal control are unable to determine the current heat state of an electric bolted connection with required accuracy. Heating control of electrical connections is suggested. To determine the state of the electrical connection, the factor of defectiveness due to heating is selected. As a result, criteria for determining the state of an electrical connection are obtained, which allows a methodology to be developed for monitoring the quality of an electrical connection.
doi_str_mv 10.3103/S1068371216020085
format Article
fullrecord <record><control><sourceid>crossref_sprin</sourceid><recordid>TN_cdi_crossref_primary_10_3103_S1068371216020085</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_3103_S1068371216020085</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2615-29d06a77ad73667dba2e681e50365f582be0c8c62f3bcbe5139a5f7c872d751a3</originalsourceid><addsrcrecordid>eNp9kMtOwzAQRS0EEqXwAez8A4EZO35kicqrUiUWwDpyHBtcpQ447qJ_j6OyQ2I1jzvnanQJuUa44Qj89hVBaq6QoQQGoMUJWWDD60oDwmnpi1zN-jm5mKYtgJCsrhdkfe-yS7sQTQ5jpKOnNoWyCYbmkfoQe5o_Hf3emyHkw6ybSN3gbE7BmoHaMcYyFPaSnHkzTO7qty7J--PD2-q52rw8rVd3m8oyiaJiTQ_SKGV6xaVUfWeYkxqdAC6FF5p1Dqy2knne2c4J5I0RXlmtWK8EGr4kePS1aZym5Hz7lcLOpEOL0M5ZtH-yKAw7MlO5jR8utdtxn2J58x_oByfsYHI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Determination of criteria to find the quality of an electrical connection</title><source>SpringerLink</source><creator>Ignatenko, I. V. ; Vlasenko, S. A.</creator><creatorcontrib>Ignatenko, I. V. ; Vlasenko, S. A.</creatorcontrib><description>A contact system is a nonredundant technical structure of electric railways that should provide uninterrupted power supply for railway vehicles. The failure of one part can lead to failure of the contact system. About 20% of damage to contact systems is due to inadmissibly high temperature at part of an overheated catenary. In this paper, normative indices are analyzed to determine the state of the terminal under operating conditions. The existing methods of thermal control are unable to determine the current heat state of an electric bolted connection with required accuracy. Heating control of electrical connections is suggested. To determine the state of the electrical connection, the factor of defectiveness due to heating is selected. As a result, criteria for determining the state of an electrical connection are obtained, which allows a methodology to be developed for monitoring the quality of an electrical connection.</description><identifier>ISSN: 1068-3712</identifier><identifier>EISSN: 1934-8010</identifier><identifier>DOI: 10.3103/S1068371216020085</identifier><language>eng</language><publisher>New York: Allerton Press</publisher><subject>Engineering ; Machines ; Manufacturing ; Processes</subject><ispartof>Russian electrical engineering, 2016-02, Vol.87 (2), p.65-67</ispartof><rights>Allerton Press, Inc. 2016</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2615-29d06a77ad73667dba2e681e50365f582be0c8c62f3bcbe5139a5f7c872d751a3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.3103/S1068371216020085$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.3103/S1068371216020085$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids></links><search><creatorcontrib>Ignatenko, I. V.</creatorcontrib><creatorcontrib>Vlasenko, S. A.</creatorcontrib><title>Determination of criteria to find the quality of an electrical connection</title><title>Russian electrical engineering</title><addtitle>Russ. Electr. Engin</addtitle><description>A contact system is a nonredundant technical structure of electric railways that should provide uninterrupted power supply for railway vehicles. The failure of one part can lead to failure of the contact system. About 20% of damage to contact systems is due to inadmissibly high temperature at part of an overheated catenary. In this paper, normative indices are analyzed to determine the state of the terminal under operating conditions. The existing methods of thermal control are unable to determine the current heat state of an electric bolted connection with required accuracy. Heating control of electrical connections is suggested. To determine the state of the electrical connection, the factor of defectiveness due to heating is selected. As a result, criteria for determining the state of an electrical connection are obtained, which allows a methodology to be developed for monitoring the quality of an electrical connection.</description><subject>Engineering</subject><subject>Machines</subject><subject>Manufacturing</subject><subject>Processes</subject><issn>1068-3712</issn><issn>1934-8010</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNp9kMtOwzAQRS0EEqXwAez8A4EZO35kicqrUiUWwDpyHBtcpQ447qJ_j6OyQ2I1jzvnanQJuUa44Qj89hVBaq6QoQQGoMUJWWDD60oDwmnpi1zN-jm5mKYtgJCsrhdkfe-yS7sQTQ5jpKOnNoWyCYbmkfoQe5o_Hf3emyHkw6ybSN3gbE7BmoHaMcYyFPaSnHkzTO7qty7J--PD2-q52rw8rVd3m8oyiaJiTQ_SKGV6xaVUfWeYkxqdAC6FF5p1Dqy2knne2c4J5I0RXlmtWK8EGr4kePS1aZym5Hz7lcLOpEOL0M5ZtH-yKAw7MlO5jR8utdtxn2J58x_oByfsYHI</recordid><startdate>20160201</startdate><enddate>20160201</enddate><creator>Ignatenko, I. V.</creator><creator>Vlasenko, S. A.</creator><general>Allerton Press</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20160201</creationdate><title>Determination of criteria to find the quality of an electrical connection</title><author>Ignatenko, I. V. ; Vlasenko, S. A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2615-29d06a77ad73667dba2e681e50365f582be0c8c62f3bcbe5139a5f7c872d751a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Engineering</topic><topic>Machines</topic><topic>Manufacturing</topic><topic>Processes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ignatenko, I. V.</creatorcontrib><creatorcontrib>Vlasenko, S. A.</creatorcontrib><collection>CrossRef</collection><jtitle>Russian electrical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ignatenko, I. V.</au><au>Vlasenko, S. A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of criteria to find the quality of an electrical connection</atitle><jtitle>Russian electrical engineering</jtitle><stitle>Russ. Electr. Engin</stitle><date>2016-02-01</date><risdate>2016</risdate><volume>87</volume><issue>2</issue><spage>65</spage><epage>67</epage><pages>65-67</pages><issn>1068-3712</issn><eissn>1934-8010</eissn><abstract>A contact system is a nonredundant technical structure of electric railways that should provide uninterrupted power supply for railway vehicles. The failure of one part can lead to failure of the contact system. About 20% of damage to contact systems is due to inadmissibly high temperature at part of an overheated catenary. In this paper, normative indices are analyzed to determine the state of the terminal under operating conditions. The existing methods of thermal control are unable to determine the current heat state of an electric bolted connection with required accuracy. Heating control of electrical connections is suggested. To determine the state of the electrical connection, the factor of defectiveness due to heating is selected. As a result, criteria for determining the state of an electrical connection are obtained, which allows a methodology to be developed for monitoring the quality of an electrical connection.</abstract><cop>New York</cop><pub>Allerton Press</pub><doi>10.3103/S1068371216020085</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1068-3712
ispartof Russian electrical engineering, 2016-02, Vol.87 (2), p.65-67
issn 1068-3712
1934-8010
language eng
recordid cdi_crossref_primary_10_3103_S1068371216020085
source SpringerLink
subjects Engineering
Machines
Manufacturing
Processes
title Determination of criteria to find the quality of an electrical connection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T12%3A57%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_sprin&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20criteria%20to%20find%20the%20quality%20of%20an%20electrical%20connection&rft.jtitle=Russian%20electrical%20engineering&rft.au=Ignatenko,%20I.%20V.&rft.date=2016-02-01&rft.volume=87&rft.issue=2&rft.spage=65&rft.epage=67&rft.pages=65-67&rft.issn=1068-3712&rft.eissn=1934-8010&rft_id=info:doi/10.3103/S1068371216020085&rft_dat=%3Ccrossref_sprin%3E10_3103_S1068371216020085%3C/crossref_sprin%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true