Optimization of the quadrupole probe-forming system with individual power supplies for lenses

This study reviews a quadruplet of magnetic quadrupole lenses, where each lens is fed from an individual power supply. In this case the power supplies of two last lenses (along the course of the beam) are selected from the condition of ensuring the stigmatic focusing, while the power supply values o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radioelectronics and communications systems 2010-02, Vol.53 (2), p.113-118
Hauptverfasser: Ponomarev, A. G., Vorobjov, G. S., Ponomarova, A. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 118
container_issue 2
container_start_page 113
container_title Radioelectronics and communications systems
container_volume 53
creator Ponomarev, A. G.
Vorobjov, G. S.
Ponomarova, A. A.
description This study reviews a quadruplet of magnetic quadrupole lenses, where each lens is fed from an individual power supply. In this case the power supplies of two last lenses (along the course of the beam) are selected from the condition of ensuring the stigmatic focusing, while the power supply values of two first lenses are free parameters. These parameters form a two-parameter set, where the functional characterizing the acceptance of a probe-forming system is determined. It has been shown that the use of four individual power supplies for lenses in the quadruplet allows us to make the acceptance more than two times larger.
doi_str_mv 10.3103/S0735272710020068
format Article
fullrecord <record><control><sourceid>crossref_sprin</sourceid><recordid>TN_cdi_crossref_primary_10_3103_S0735272710020068</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_3103_S0735272710020068</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2038-7007d8c08e285c4dfb54c19b11d084113af6660c2ac502f83e631ccdff6238763</originalsourceid><addsrcrecordid>eNp9kM1KAzEcxIMoWKsP4C0vsPpPssmmRyl-QaEH9ShLmo82ZXcTk11LffpuqTfB0xxmfsMwCN0SuGME2P0bVIzTilYEgAIIeYYmZMbKQoIg52hytIujf4muct4CcD7jdII-l7H3rf9RvQ8dDg73G4u_BmXSEENjcUxhZQsXUuu7Nc773NsW73y_wb4z_tubQTU4hp1NOA8xNt5mPKZxY7ts8zW6cKrJ9uZXp-jj6fF9_lIsls-v84dFoSkwWVQAlZEapKWS69K4FS81ma0IMSBLQphyQgjQVGkO1ElmBSNaG-cEZbISbIrIqVenkHOyro7JtyrtawL18Z_6zz8jQ09MHrPd2qZ6G4bUjTP_gQ6ZTGig</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Optimization of the quadrupole probe-forming system with individual power supplies for lenses</title><source>SpringerNature Journals</source><creator>Ponomarev, A. G. ; Vorobjov, G. S. ; Ponomarova, A. A.</creator><creatorcontrib>Ponomarev, A. G. ; Vorobjov, G. S. ; Ponomarova, A. A.</creatorcontrib><description>This study reviews a quadruplet of magnetic quadrupole lenses, where each lens is fed from an individual power supply. In this case the power supplies of two last lenses (along the course of the beam) are selected from the condition of ensuring the stigmatic focusing, while the power supply values of two first lenses are free parameters. These parameters form a two-parameter set, where the functional characterizing the acceptance of a probe-forming system is determined. It has been shown that the use of four individual power supplies for lenses in the quadruplet allows us to make the acceptance more than two times larger.</description><identifier>ISSN: 0735-2727</identifier><identifier>EISSN: 1934-8061</identifier><identifier>DOI: 10.3103/S0735272710020068</identifier><language>eng</language><publisher>Heidelberg: Allerton Press, Inc</publisher><subject>Communications Engineering ; Engineering ; Networks</subject><ispartof>Radioelectronics and communications systems, 2010-02, Vol.53 (2), p.113-118</ispartof><rights>Allerton Press, Inc. 2010</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2038-7007d8c08e285c4dfb54c19b11d084113af6660c2ac502f83e631ccdff6238763</citedby><cites>FETCH-LOGICAL-c2038-7007d8c08e285c4dfb54c19b11d084113af6660c2ac502f83e631ccdff6238763</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.3103/S0735272710020068$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.3103/S0735272710020068$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids></links><search><creatorcontrib>Ponomarev, A. G.</creatorcontrib><creatorcontrib>Vorobjov, G. S.</creatorcontrib><creatorcontrib>Ponomarova, A. A.</creatorcontrib><title>Optimization of the quadrupole probe-forming system with individual power supplies for lenses</title><title>Radioelectronics and communications systems</title><addtitle>Radioelectron.Commun.Syst</addtitle><description>This study reviews a quadruplet of magnetic quadrupole lenses, where each lens is fed from an individual power supply. In this case the power supplies of two last lenses (along the course of the beam) are selected from the condition of ensuring the stigmatic focusing, while the power supply values of two first lenses are free parameters. These parameters form a two-parameter set, where the functional characterizing the acceptance of a probe-forming system is determined. It has been shown that the use of four individual power supplies for lenses in the quadruplet allows us to make the acceptance more than two times larger.</description><subject>Communications Engineering</subject><subject>Engineering</subject><subject>Networks</subject><issn>0735-2727</issn><issn>1934-8061</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9kM1KAzEcxIMoWKsP4C0vsPpPssmmRyl-QaEH9ShLmo82ZXcTk11LffpuqTfB0xxmfsMwCN0SuGME2P0bVIzTilYEgAIIeYYmZMbKQoIg52hytIujf4muct4CcD7jdII-l7H3rf9RvQ8dDg73G4u_BmXSEENjcUxhZQsXUuu7Nc773NsW73y_wb4z_tubQTU4hp1NOA8xNt5mPKZxY7ts8zW6cKrJ9uZXp-jj6fF9_lIsls-v84dFoSkwWVQAlZEapKWS69K4FS81ma0IMSBLQphyQgjQVGkO1ElmBSNaG-cEZbISbIrIqVenkHOyro7JtyrtawL18Z_6zz8jQ09MHrPd2qZ6G4bUjTP_gQ6ZTGig</recordid><startdate>201002</startdate><enddate>201002</enddate><creator>Ponomarev, A. G.</creator><creator>Vorobjov, G. S.</creator><creator>Ponomarova, A. A.</creator><general>Allerton Press, Inc</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201002</creationdate><title>Optimization of the quadrupole probe-forming system with individual power supplies for lenses</title><author>Ponomarev, A. G. ; Vorobjov, G. S. ; Ponomarova, A. A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2038-7007d8c08e285c4dfb54c19b11d084113af6660c2ac502f83e631ccdff6238763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Communications Engineering</topic><topic>Engineering</topic><topic>Networks</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ponomarev, A. G.</creatorcontrib><creatorcontrib>Vorobjov, G. S.</creatorcontrib><creatorcontrib>Ponomarova, A. A.</creatorcontrib><collection>CrossRef</collection><jtitle>Radioelectronics and communications systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ponomarev, A. G.</au><au>Vorobjov, G. S.</au><au>Ponomarova, A. A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of the quadrupole probe-forming system with individual power supplies for lenses</atitle><jtitle>Radioelectronics and communications systems</jtitle><stitle>Radioelectron.Commun.Syst</stitle><date>2010-02</date><risdate>2010</risdate><volume>53</volume><issue>2</issue><spage>113</spage><epage>118</epage><pages>113-118</pages><issn>0735-2727</issn><eissn>1934-8061</eissn><abstract>This study reviews a quadruplet of magnetic quadrupole lenses, where each lens is fed from an individual power supply. In this case the power supplies of two last lenses (along the course of the beam) are selected from the condition of ensuring the stigmatic focusing, while the power supply values of two first lenses are free parameters. These parameters form a two-parameter set, where the functional characterizing the acceptance of a probe-forming system is determined. It has been shown that the use of four individual power supplies for lenses in the quadruplet allows us to make the acceptance more than two times larger.</abstract><cop>Heidelberg</cop><pub>Allerton Press, Inc</pub><doi>10.3103/S0735272710020068</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0735-2727
ispartof Radioelectronics and communications systems, 2010-02, Vol.53 (2), p.113-118
issn 0735-2727
1934-8061
language eng
recordid cdi_crossref_primary_10_3103_S0735272710020068
source SpringerNature Journals
subjects Communications Engineering
Engineering
Networks
title Optimization of the quadrupole probe-forming system with individual power supplies for lenses
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T00%3A01%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_sprin&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%20the%20quadrupole%20probe-forming%20system%20with%20individual%20power%20supplies%20for%20lenses&rft.jtitle=Radioelectronics%20and%20communications%20systems&rft.au=Ponomarev,%20A.%20G.&rft.date=2010-02&rft.volume=53&rft.issue=2&rft.spage=113&rft.epage=118&rft.pages=113-118&rft.issn=0735-2727&rft.eissn=1934-8061&rft_id=info:doi/10.3103/S0735272710020068&rft_dat=%3Ccrossref_sprin%3E10_3103_S0735272710020068%3C/crossref_sprin%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true