Continuous Glucose Monitoring in the Management of Pancreatic Diabetes Complicated by Pancreatic Insufficiency

Digestive enzyme and insulin replacement therapy are needed for patients with pancreatic diabetes complicated by pancreatic exocrine insufficiency. We determine the effect of these treatments based on nutritional assessment and glycemic control. We use HbA1c and glycoalbumin levels for assessment of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Suizo 2020/04/30, Vol.35(2), pp.145-152
Hauptverfasser: YANAGIMACHI, Miyuki, FUJITA, Tomoyuki, YAMAICHI, Masato, MATSUMOTO, Atsufumi, NAKAYAMA, Hirofumi, NAKAMURA, Ryoma, SATO, Eri, TANDO, Yusuke, DAIMON, Makoto, NAKAMURA, Teruo
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 152
container_issue 2
container_start_page 145
container_title Suizo
container_volume 35
creator YANAGIMACHI, Miyuki
FUJITA, Tomoyuki
YAMAICHI, Masato
MATSUMOTO, Atsufumi
NAKAYAMA, Hirofumi
NAKAMURA, Ryoma
SATO, Eri
TANDO, Yusuke
DAIMON, Makoto
NAKAMURA, Teruo
description Digestive enzyme and insulin replacement therapy are needed for patients with pancreatic diabetes complicated by pancreatic exocrine insufficiency. We determine the effect of these treatments based on nutritional assessment and glycemic control. We use HbA1c and glycoalbumin levels for assessment of long-term glycemic control, and SMBG (self-monitoring of blood glucose) to assess the daily blood glucose profile. However, the confirmation of unconscious hypoglycemia and nocturnal hypoglycemia is difficult using these methods.Continuous glucose monitoring is effective for the confirmation of unconscious hypoglycemia and nocturnal hypoglycemia. Objective assessment of hypoglycemia frequency is enabled by adding "time below target glucose range: TBR" as an assessment item for glycemic control.
doi_str_mv 10.2958/suizo.35.145
format Article
fullrecord <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_2958_suizo_35_145</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_suizo_35_2_35_145_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1315-fd28dafbe09ea4ea86039a10a7172253c6a0706a9a7f6f2e6089e4a534defa5e3</originalsourceid><addsrcrecordid>eNpNkMtOwzAQRS0EEqWw4wP8AaT4EeexQqhAqVQEC1hHU2fcukrtynYW5esJFBVWI82cO9I9hFxzNhG1qm5jbz_9RKoJz9UJGfGq4pmomDolI1ZzmTFW8nNyEeOGMSWKshgRN_UuWdf7PtJZ12sfkb54Z5MP1q2odTSthw04WOEWXaLe0DdwOiAkq-mDhSUmjHTqt7vOakjY0uX-PzJ3sTfGaotO7y_JmYEu4tXvHJOPp8f36XO2eJ3Np_eLTHPJVWZaUbVglshqhByhKpisgTMoeSmEkroAVrICaihNYQQWrKoxByXzFg0olGNyc_irg48xoGl2wW4h7BvOmm9XzY-rRqpmcDXgdwd8E9NQ9AhDGBp0-AeL38TxotcQGnTyCzK0d9Y</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Continuous Glucose Monitoring in the Management of Pancreatic Diabetes Complicated by Pancreatic Insufficiency</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>YANAGIMACHI, Miyuki ; FUJITA, Tomoyuki ; YAMAICHI, Masato ; MATSUMOTO, Atsufumi ; NAKAYAMA, Hirofumi ; NAKAMURA, Ryoma ; SATO, Eri ; TANDO, Yusuke ; DAIMON, Makoto ; NAKAMURA, Teruo</creator><creatorcontrib>YANAGIMACHI, Miyuki ; FUJITA, Tomoyuki ; YAMAICHI, Masato ; MATSUMOTO, Atsufumi ; NAKAYAMA, Hirofumi ; NAKAMURA, Ryoma ; SATO, Eri ; TANDO, Yusuke ; DAIMON, Makoto ; NAKAMURA, Teruo</creatorcontrib><description>Digestive enzyme and insulin replacement therapy are needed for patients with pancreatic diabetes complicated by pancreatic exocrine insufficiency. We determine the effect of these treatments based on nutritional assessment and glycemic control. We use HbA1c and glycoalbumin levels for assessment of long-term glycemic control, and SMBG (self-monitoring of blood glucose) to assess the daily blood glucose profile. However, the confirmation of unconscious hypoglycemia and nocturnal hypoglycemia is difficult using these methods.Continuous glucose monitoring is effective for the confirmation of unconscious hypoglycemia and nocturnal hypoglycemia. Objective assessment of hypoglycemia frequency is enabled by adding "time below target glucose range: TBR" as an assessment item for glycemic control.</description><identifier>ISSN: 0913-0071</identifier><identifier>EISSN: 1881-2805</identifier><identifier>DOI: 10.2958/suizo.35.145</identifier><language>eng ; jpn</language><publisher>Japan Pancreas Society</publisher><subject>Continuous glucose monitoring ; Pancreatic diabetes ; Time below target range (TBR) ; Unconscious hypoglycemia</subject><ispartof>Suizo, 2020/04/30, Vol.35(2), pp.145-152</ispartof><rights>2020 Japan Pancreas Society</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1315-fd28dafbe09ea4ea86039a10a7172253c6a0706a9a7f6f2e6089e4a534defa5e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1883,27924,27925</link.rule.ids></links><search><creatorcontrib>YANAGIMACHI, Miyuki</creatorcontrib><creatorcontrib>FUJITA, Tomoyuki</creatorcontrib><creatorcontrib>YAMAICHI, Masato</creatorcontrib><creatorcontrib>MATSUMOTO, Atsufumi</creatorcontrib><creatorcontrib>NAKAYAMA, Hirofumi</creatorcontrib><creatorcontrib>NAKAMURA, Ryoma</creatorcontrib><creatorcontrib>SATO, Eri</creatorcontrib><creatorcontrib>TANDO, Yusuke</creatorcontrib><creatorcontrib>DAIMON, Makoto</creatorcontrib><creatorcontrib>NAKAMURA, Teruo</creatorcontrib><title>Continuous Glucose Monitoring in the Management of Pancreatic Diabetes Complicated by Pancreatic Insufficiency</title><title>Suizo</title><addtitle>Suizo</addtitle><description>Digestive enzyme and insulin replacement therapy are needed for patients with pancreatic diabetes complicated by pancreatic exocrine insufficiency. We determine the effect of these treatments based on nutritional assessment and glycemic control. We use HbA1c and glycoalbumin levels for assessment of long-term glycemic control, and SMBG (self-monitoring of blood glucose) to assess the daily blood glucose profile. However, the confirmation of unconscious hypoglycemia and nocturnal hypoglycemia is difficult using these methods.Continuous glucose monitoring is effective for the confirmation of unconscious hypoglycemia and nocturnal hypoglycemia. Objective assessment of hypoglycemia frequency is enabled by adding "time below target glucose range: TBR" as an assessment item for glycemic control.</description><subject>Continuous glucose monitoring</subject><subject>Pancreatic diabetes</subject><subject>Time below target range (TBR)</subject><subject>Unconscious hypoglycemia</subject><issn>0913-0071</issn><issn>1881-2805</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpNkMtOwzAQRS0EEqWw4wP8AaT4EeexQqhAqVQEC1hHU2fcukrtynYW5esJFBVWI82cO9I9hFxzNhG1qm5jbz_9RKoJz9UJGfGq4pmomDolI1ZzmTFW8nNyEeOGMSWKshgRN_UuWdf7PtJZ12sfkb54Z5MP1q2odTSthw04WOEWXaLe0DdwOiAkq-mDhSUmjHTqt7vOakjY0uX-PzJ3sTfGaotO7y_JmYEu4tXvHJOPp8f36XO2eJ3Np_eLTHPJVWZaUbVglshqhByhKpisgTMoeSmEkroAVrICaihNYQQWrKoxByXzFg0olGNyc_irg48xoGl2wW4h7BvOmm9XzY-rRqpmcDXgdwd8E9NQ9AhDGBp0-AeL38TxotcQGnTyCzK0d9Y</recordid><startdate>20200430</startdate><enddate>20200430</enddate><creator>YANAGIMACHI, Miyuki</creator><creator>FUJITA, Tomoyuki</creator><creator>YAMAICHI, Masato</creator><creator>MATSUMOTO, Atsufumi</creator><creator>NAKAYAMA, Hirofumi</creator><creator>NAKAMURA, Ryoma</creator><creator>SATO, Eri</creator><creator>TANDO, Yusuke</creator><creator>DAIMON, Makoto</creator><creator>NAKAMURA, Teruo</creator><general>Japan Pancreas Society</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20200430</creationdate><title>Continuous Glucose Monitoring in the Management of Pancreatic Diabetes Complicated by Pancreatic Insufficiency</title><author>YANAGIMACHI, Miyuki ; FUJITA, Tomoyuki ; YAMAICHI, Masato ; MATSUMOTO, Atsufumi ; NAKAYAMA, Hirofumi ; NAKAMURA, Ryoma ; SATO, Eri ; TANDO, Yusuke ; DAIMON, Makoto ; NAKAMURA, Teruo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1315-fd28dafbe09ea4ea86039a10a7172253c6a0706a9a7f6f2e6089e4a534defa5e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2020</creationdate><topic>Continuous glucose monitoring</topic><topic>Pancreatic diabetes</topic><topic>Time below target range (TBR)</topic><topic>Unconscious hypoglycemia</topic><toplevel>online_resources</toplevel><creatorcontrib>YANAGIMACHI, Miyuki</creatorcontrib><creatorcontrib>FUJITA, Tomoyuki</creatorcontrib><creatorcontrib>YAMAICHI, Masato</creatorcontrib><creatorcontrib>MATSUMOTO, Atsufumi</creatorcontrib><creatorcontrib>NAKAYAMA, Hirofumi</creatorcontrib><creatorcontrib>NAKAMURA, Ryoma</creatorcontrib><creatorcontrib>SATO, Eri</creatorcontrib><creatorcontrib>TANDO, Yusuke</creatorcontrib><creatorcontrib>DAIMON, Makoto</creatorcontrib><creatorcontrib>NAKAMURA, Teruo</creatorcontrib><collection>CrossRef</collection><jtitle>Suizo</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>YANAGIMACHI, Miyuki</au><au>FUJITA, Tomoyuki</au><au>YAMAICHI, Masato</au><au>MATSUMOTO, Atsufumi</au><au>NAKAYAMA, Hirofumi</au><au>NAKAMURA, Ryoma</au><au>SATO, Eri</au><au>TANDO, Yusuke</au><au>DAIMON, Makoto</au><au>NAKAMURA, Teruo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Continuous Glucose Monitoring in the Management of Pancreatic Diabetes Complicated by Pancreatic Insufficiency</atitle><jtitle>Suizo</jtitle><addtitle>Suizo</addtitle><date>2020-04-30</date><risdate>2020</risdate><volume>35</volume><issue>2</issue><spage>145</spage><epage>152</epage><pages>145-152</pages><issn>0913-0071</issn><eissn>1881-2805</eissn><abstract>Digestive enzyme and insulin replacement therapy are needed for patients with pancreatic diabetes complicated by pancreatic exocrine insufficiency. We determine the effect of these treatments based on nutritional assessment and glycemic control. We use HbA1c and glycoalbumin levels for assessment of long-term glycemic control, and SMBG (self-monitoring of blood glucose) to assess the daily blood glucose profile. However, the confirmation of unconscious hypoglycemia and nocturnal hypoglycemia is difficult using these methods.Continuous glucose monitoring is effective for the confirmation of unconscious hypoglycemia and nocturnal hypoglycemia. Objective assessment of hypoglycemia frequency is enabled by adding "time below target glucose range: TBR" as an assessment item for glycemic control.</abstract><pub>Japan Pancreas Society</pub><doi>10.2958/suizo.35.145</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0913-0071
ispartof Suizo, 2020/04/30, Vol.35(2), pp.145-152
issn 0913-0071
1881-2805
language eng ; jpn
recordid cdi_crossref_primary_10_2958_suizo_35_145
source J-STAGE Free; EZB-FREE-00999 freely available EZB journals
subjects Continuous glucose monitoring
Pancreatic diabetes
Time below target range (TBR)
Unconscious hypoglycemia
title Continuous Glucose Monitoring in the Management of Pancreatic Diabetes Complicated by Pancreatic Insufficiency
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T14%3A56%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Continuous%20Glucose%20Monitoring%20in%20the%20Management%20of%20Pancreatic%20Diabetes%20Complicated%20by%20Pancreatic%20Insufficiency&rft.jtitle=Suizo&rft.au=YANAGIMACHI,%20Miyuki&rft.date=2020-04-30&rft.volume=35&rft.issue=2&rft.spage=145&rft.epage=152&rft.pages=145-152&rft.issn=0913-0071&rft.eissn=1881-2805&rft_id=info:doi/10.2958/suizo.35.145&rft_dat=%3Cjstage_cross%3Earticle_suizo_35_2_35_145_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true