Development of a single expandable PEIT needle and its clinical application
The current mainstream percutaneous local treatment for HCC is RFA with supplementary PEIT. PEIT is sometimes employed for HCC in high-risk locations, such as HCC close to the heart. However, even with PEIT it is markedly difficult to treat HCC located at the back ofblood vessels deep in the liver....
Gespeichert in:
Veröffentlicht in: | Kanzo 2011, Vol.52(8), pp.528-531 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng ; jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 531 |
---|---|
container_issue | 8 |
container_start_page | 528 |
container_title | Kanzo |
container_volume | 52 |
creator | Mitsumoto, Yasuhide Mori, Takahiro Itou, Tadashi Shimizu, Seiji Nakajima, Tomoki Okanoue, Takeshi Yasui, Kohichiroh Ito, Yoshito Yoshikawa, Toshikazu |
description | The current mainstream percutaneous local treatment for HCC is RFA with supplementary PEIT. PEIT is sometimes employed for HCC in high-risk locations, such as HCC close to the heart. However, even with PEIT it is markedly difficult to treat HCC located at the back ofblood vessels deep in the liver. We developed a single expandable PEIT needle to treat difficult-to-puncture HCC. The tip of an inner needle can be expandable vertically to the long axis. We used this technique to successfully treat a case of HCC in S1 at the back of portal vein at the liver hilum. The needle is equipped with features absent in other devices and is expected to become a new option for percutaneous local therapy of HCC. |
doi_str_mv | 10.2957/kanzo.52.528 |
format | Article |
fullrecord | <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_2957_kanzo_52_528</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_kanzo_52_8_52_8_528_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2038-3f698cc5254438f933df1ad20a376f10c14f55e8d9b62221a7c734b4625016553</originalsourceid><addsrcrecordid>eNpFkN1KAzEQhYMoWGrvfIA8gFvzu5tcllq1WNCLer3MZpMaTbPLZhH16Y1_FQ4zh5mPYTgInVMyZ1pWly8QP7q5ZFnqCE2oUrTgUvNjNCFC0kIwwk_RLCXfEMLKimjNJujuyr7a0PV7G0fcOQw4-bgLFtu3HmILTbYPq_UWR2vb7PMM-zFhE3z0BgKGvg_ZjL6LZ-jEQUh29tun6PF6tV3eFpv7m_VysSlMfkEV3JVaGSOZFIIrpzlvHYWWEeBV6SgxVDgprWp1UzLGKFSm4qIRJZOEllLyKbr4uWuGLqXBurof_B6G95qS-iuL-juLWrIslfHFD_6cRtjZAwzD6E2w_7D6K-qwM08w1DbyT7R5aYI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Development of a single expandable PEIT needle and its clinical application</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Mitsumoto, Yasuhide ; Mori, Takahiro ; Itou, Tadashi ; Shimizu, Seiji ; Nakajima, Tomoki ; Okanoue, Takeshi ; Yasui, Kohichiroh ; Ito, Yoshito ; Yoshikawa, Toshikazu</creator><creatorcontrib>Mitsumoto, Yasuhide ; Mori, Takahiro ; Itou, Tadashi ; Shimizu, Seiji ; Nakajima, Tomoki ; Okanoue, Takeshi ; Yasui, Kohichiroh ; Ito, Yoshito ; Yoshikawa, Toshikazu</creatorcontrib><description>The current mainstream percutaneous local treatment for HCC is RFA with supplementary PEIT. PEIT is sometimes employed for HCC in high-risk locations, such as HCC close to the heart. However, even with PEIT it is markedly difficult to treat HCC located at the back ofblood vessels deep in the liver. We developed a single expandable PEIT needle to treat difficult-to-puncture HCC. The tip of an inner needle can be expandable vertically to the long axis. We used this technique to successfully treat a case of HCC in S1 at the back of portal vein at the liver hilum. The needle is equipped with features absent in other devices and is expected to become a new option for percutaneous local therapy of HCC.</description><identifier>ISSN: 0451-4203</identifier><identifier>EISSN: 1881-3593</identifier><identifier>DOI: 10.2957/kanzo.52.528</identifier><language>eng ; jpn</language><publisher>The Japan Society of Hepatology</publisher><subject>HCC ; PEIT ; single expandable PEIT needle</subject><ispartof>Kanzo, 2011, Vol.52(8), pp.528-531</ispartof><rights>2011 The Japan Society of Hepatology</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2038-3f698cc5254438f933df1ad20a376f10c14f55e8d9b62221a7c734b4625016553</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1883,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Mitsumoto, Yasuhide</creatorcontrib><creatorcontrib>Mori, Takahiro</creatorcontrib><creatorcontrib>Itou, Tadashi</creatorcontrib><creatorcontrib>Shimizu, Seiji</creatorcontrib><creatorcontrib>Nakajima, Tomoki</creatorcontrib><creatorcontrib>Okanoue, Takeshi</creatorcontrib><creatorcontrib>Yasui, Kohichiroh</creatorcontrib><creatorcontrib>Ito, Yoshito</creatorcontrib><creatorcontrib>Yoshikawa, Toshikazu</creatorcontrib><title>Development of a single expandable PEIT needle and its clinical application</title><title>Kanzo</title><addtitle>Kanzo</addtitle><description>The current mainstream percutaneous local treatment for HCC is RFA with supplementary PEIT. PEIT is sometimes employed for HCC in high-risk locations, such as HCC close to the heart. However, even with PEIT it is markedly difficult to treat HCC located at the back ofblood vessels deep in the liver. We developed a single expandable PEIT needle to treat difficult-to-puncture HCC. The tip of an inner needle can be expandable vertically to the long axis. We used this technique to successfully treat a case of HCC in S1 at the back of portal vein at the liver hilum. The needle is equipped with features absent in other devices and is expected to become a new option for percutaneous local therapy of HCC.</description><subject>HCC</subject><subject>PEIT</subject><subject>single expandable PEIT needle</subject><issn>0451-4203</issn><issn>1881-3593</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNpFkN1KAzEQhYMoWGrvfIA8gFvzu5tcllq1WNCLer3MZpMaTbPLZhH16Y1_FQ4zh5mPYTgInVMyZ1pWly8QP7q5ZFnqCE2oUrTgUvNjNCFC0kIwwk_RLCXfEMLKimjNJujuyr7a0PV7G0fcOQw4-bgLFtu3HmILTbYPq_UWR2vb7PMM-zFhE3z0BgKGvg_ZjL6LZ-jEQUh29tun6PF6tV3eFpv7m_VysSlMfkEV3JVaGSOZFIIrpzlvHYWWEeBV6SgxVDgprWp1UzLGKFSm4qIRJZOEllLyKbr4uWuGLqXBurof_B6G95qS-iuL-juLWrIslfHFD_6cRtjZAwzD6E2w_7D6K-qwM08w1DbyT7R5aYI</recordid><startdate>2011</startdate><enddate>2011</enddate><creator>Mitsumoto, Yasuhide</creator><creator>Mori, Takahiro</creator><creator>Itou, Tadashi</creator><creator>Shimizu, Seiji</creator><creator>Nakajima, Tomoki</creator><creator>Okanoue, Takeshi</creator><creator>Yasui, Kohichiroh</creator><creator>Ito, Yoshito</creator><creator>Yoshikawa, Toshikazu</creator><general>The Japan Society of Hepatology</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2011</creationdate><title>Development of a single expandable PEIT needle and its clinical application</title><author>Mitsumoto, Yasuhide ; Mori, Takahiro ; Itou, Tadashi ; Shimizu, Seiji ; Nakajima, Tomoki ; Okanoue, Takeshi ; Yasui, Kohichiroh ; Ito, Yoshito ; Yoshikawa, Toshikazu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2038-3f698cc5254438f933df1ad20a376f10c14f55e8d9b62221a7c734b4625016553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2011</creationdate><topic>HCC</topic><topic>PEIT</topic><topic>single expandable PEIT needle</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mitsumoto, Yasuhide</creatorcontrib><creatorcontrib>Mori, Takahiro</creatorcontrib><creatorcontrib>Itou, Tadashi</creatorcontrib><creatorcontrib>Shimizu, Seiji</creatorcontrib><creatorcontrib>Nakajima, Tomoki</creatorcontrib><creatorcontrib>Okanoue, Takeshi</creatorcontrib><creatorcontrib>Yasui, Kohichiroh</creatorcontrib><creatorcontrib>Ito, Yoshito</creatorcontrib><creatorcontrib>Yoshikawa, Toshikazu</creatorcontrib><collection>CrossRef</collection><jtitle>Kanzo</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mitsumoto, Yasuhide</au><au>Mori, Takahiro</au><au>Itou, Tadashi</au><au>Shimizu, Seiji</au><au>Nakajima, Tomoki</au><au>Okanoue, Takeshi</au><au>Yasui, Kohichiroh</au><au>Ito, Yoshito</au><au>Yoshikawa, Toshikazu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a single expandable PEIT needle and its clinical application</atitle><jtitle>Kanzo</jtitle><addtitle>Kanzo</addtitle><date>2011</date><risdate>2011</risdate><volume>52</volume><issue>8</issue><spage>528</spage><epage>531</epage><pages>528-531</pages><issn>0451-4203</issn><eissn>1881-3593</eissn><abstract>The current mainstream percutaneous local treatment for HCC is RFA with supplementary PEIT. PEIT is sometimes employed for HCC in high-risk locations, such as HCC close to the heart. However, even with PEIT it is markedly difficult to treat HCC located at the back ofblood vessels deep in the liver. We developed a single expandable PEIT needle to treat difficult-to-puncture HCC. The tip of an inner needle can be expandable vertically to the long axis. We used this technique to successfully treat a case of HCC in S1 at the back of portal vein at the liver hilum. The needle is equipped with features absent in other devices and is expected to become a new option for percutaneous local therapy of HCC.</abstract><pub>The Japan Society of Hepatology</pub><doi>10.2957/kanzo.52.528</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0451-4203 |
ispartof | Kanzo, 2011, Vol.52(8), pp.528-531 |
issn | 0451-4203 1881-3593 |
language | eng ; jpn |
recordid | cdi_crossref_primary_10_2957_kanzo_52_528 |
source | J-STAGE Free; EZB-FREE-00999 freely available EZB journals |
subjects | HCC PEIT single expandable PEIT needle |
title | Development of a single expandable PEIT needle and its clinical application |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T14%3A54%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20single%20expandable%20PEIT%20needle%20and%20its%20clinical%20application&rft.jtitle=Kanzo&rft.au=Mitsumoto,%20Yasuhide&rft.date=2011&rft.volume=52&rft.issue=8&rft.spage=528&rft.epage=531&rft.pages=528-531&rft.issn=0451-4203&rft.eissn=1881-3593&rft_id=info:doi/10.2957/kanzo.52.528&rft_dat=%3Cjstage_cross%3Earticle_kanzo_52_8_52_8_528_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |