On the relationship between the pipeline length, inside diameter, compressed air pressure and time required for raw milk transportation through polyethylene pipe on level land

1) To furnish technological basis for the design of equipments for level land transportation of raw milk, experiments were conducted by using water instead of raw milk and polyethylene pipeline with inside diameter of 0.029m. And, a theoretical analysis was conducted upon basis of that, at a time po...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nihon Chikusan Gakkaiho 1971/11/25, Vol.42(11), pp.570-576
Hauptverfasser: HAMADA, Hiroshi, KOISHIKAWA, Tsunekichi, ISHII, Tokuzo, IRIE, Ryozaburo, OHTA, Eiichi
Format: Artikel
Sprache:jpn
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 576
container_issue 11
container_start_page 570
container_title Nihon Chikusan Gakkaiho
container_volume 42
creator HAMADA, Hiroshi
KOISHIKAWA, Tsunekichi
ISHII, Tokuzo
IRIE, Ryozaburo
OHTA, Eiichi
description 1) To furnish technological basis for the design of equipments for level land transportation of raw milk, experiments were conducted by using water instead of raw milk and polyethylene pipeline with inside diameter of 0.029m. And, a theoretical analysis was conducted upon basis of that, at a time point when the water-flow came to an optional position of the pipeline the following equation is attainable; From above equation a theoretical formula was derived by approximate calculation as below. 2) The actually observed values of t well agreed with the values calculated from formula (5) when 0.03 was substituted for λ. 3) In case of raw milk transportation by means of polyethylene pipeline with inside diameter of 0.029m, the equipments could be designed upon basis of calculation by the same formula except for substituting 0.035 for λ.
doi_str_mv 10.2508/chikusan.42.570
format Article
fullrecord <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_2508_chikusan_42_570</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_chikusan1924_42_11_42_11_570_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2050-e2c51c8194f60d5fa8a60b4d27cdf2d27918129335d9813465996df026f19ca43</originalsourceid><addsrcrecordid>eNpNUE1P3DAQjapWKgLOvc4PIIvtxEl8rBCFIiQuIHGLvPZk4-I4Yewt2l_FX6yXBdTLvJHel_SK4gdnKyFZd25G97SNOqxqsZIt-1Ic8a5jZSek_Jr_qm5KxdrH78VpjG7NWMVbzlpxVLzeBUgjAqHXyc0hjm6BNaYXxAOxuAW9CwgewyaNZ-BCdBbBOj1hQjoDM08LYYxoQTuCt39LCDpYSG7aZz9vHWV6mAlIv8Dk_BMk0iEuM6W33txF83YzwjL7HaZxl-sO5ZBJj3_Rg8-JJ8W3QfuIp-94XDz8ury_uC5v765-X_y8LY1gkpUojOSm46oeGmbloDvdsHVtRWvsIDIo3nGhqkpa1e3nkUo1dmCiGbgyuq6Oi_NDrqE5RsKhX8hNmnY9Z_1-8v5j8r4WfZ48O24Ojj8x6Q1-6jUlZzx-6rkS9d7D-fvN5v9EmnoM1T9AUJWt</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>On the relationship between the pipeline length, inside diameter, compressed air pressure and time required for raw milk transportation through polyethylene pipe on level land</title><source>Alma/SFX Local Collection</source><creator>HAMADA, Hiroshi ; KOISHIKAWA, Tsunekichi ; ISHII, Tokuzo ; IRIE, Ryozaburo ; OHTA, Eiichi</creator><creatorcontrib>HAMADA, Hiroshi ; KOISHIKAWA, Tsunekichi ; ISHII, Tokuzo ; IRIE, Ryozaburo ; OHTA, Eiichi</creatorcontrib><description>1) To furnish technological basis for the design of equipments for level land transportation of raw milk, experiments were conducted by using water instead of raw milk and polyethylene pipeline with inside diameter of 0.029m. And, a theoretical analysis was conducted upon basis of that, at a time point when the water-flow came to an optional position of the pipeline the following equation is attainable; From above equation a theoretical formula was derived by approximate calculation as below. 2) The actually observed values of t well agreed with the values calculated from formula (5) when 0.03 was substituted for λ. 3) In case of raw milk transportation by means of polyethylene pipeline with inside diameter of 0.029m, the equipments could be designed upon basis of calculation by the same formula except for substituting 0.035 for λ.</description><identifier>ISSN: 1346-907X</identifier><identifier>EISSN: 1880-8255</identifier><identifier>DOI: 10.2508/chikusan.42.570</identifier><language>jpn</language><publisher>Japanese Society of Animal Science</publisher><ispartof>Nihon Chikusan Gakkaiho, 1971/11/25, Vol.42(11), pp.570-576</ispartof><rights>Japanese Society of Animal Science</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4022,27921,27922,27923</link.rule.ids></links><search><creatorcontrib>HAMADA, Hiroshi</creatorcontrib><creatorcontrib>KOISHIKAWA, Tsunekichi</creatorcontrib><creatorcontrib>ISHII, Tokuzo</creatorcontrib><creatorcontrib>IRIE, Ryozaburo</creatorcontrib><creatorcontrib>OHTA, Eiichi</creatorcontrib><title>On the relationship between the pipeline length, inside diameter, compressed air pressure and time required for raw milk transportation through polyethylene pipe on level land</title><title>Nihon Chikusan Gakkaiho</title><addtitle>Nihon Chikusan Gakkaiho</addtitle><description>1) To furnish technological basis for the design of equipments for level land transportation of raw milk, experiments were conducted by using water instead of raw milk and polyethylene pipeline with inside diameter of 0.029m. And, a theoretical analysis was conducted upon basis of that, at a time point when the water-flow came to an optional position of the pipeline the following equation is attainable; From above equation a theoretical formula was derived by approximate calculation as below. 2) The actually observed values of t well agreed with the values calculated from formula (5) when 0.03 was substituted for λ. 3) In case of raw milk transportation by means of polyethylene pipeline with inside diameter of 0.029m, the equipments could be designed upon basis of calculation by the same formula except for substituting 0.035 for λ.</description><issn>1346-907X</issn><issn>1880-8255</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1971</creationdate><recordtype>article</recordtype><recordid>eNpNUE1P3DAQjapWKgLOvc4PIIvtxEl8rBCFIiQuIHGLvPZk4-I4Yewt2l_FX6yXBdTLvJHel_SK4gdnKyFZd25G97SNOqxqsZIt-1Ic8a5jZSek_Jr_qm5KxdrH78VpjG7NWMVbzlpxVLzeBUgjAqHXyc0hjm6BNaYXxAOxuAW9CwgewyaNZ-BCdBbBOj1hQjoDM08LYYxoQTuCt39LCDpYSG7aZz9vHWV6mAlIv8Dk_BMk0iEuM6W33txF83YzwjL7HaZxl-sO5ZBJj3_Rg8-JJ8W3QfuIp-94XDz8ury_uC5v765-X_y8LY1gkpUojOSm46oeGmbloDvdsHVtRWvsIDIo3nGhqkpa1e3nkUo1dmCiGbgyuq6Oi_NDrqE5RsKhX8hNmnY9Z_1-8v5j8r4WfZ48O24Ojj8x6Q1-6jUlZzx-6rkS9d7D-fvN5v9EmnoM1T9AUJWt</recordid><startdate>1971</startdate><enddate>1971</enddate><creator>HAMADA, Hiroshi</creator><creator>KOISHIKAWA, Tsunekichi</creator><creator>ISHII, Tokuzo</creator><creator>IRIE, Ryozaburo</creator><creator>OHTA, Eiichi</creator><general>Japanese Society of Animal Science</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1971</creationdate><title>On the relationship between the pipeline length, inside diameter, compressed air pressure and time required for raw milk transportation through polyethylene pipe on level land</title><author>HAMADA, Hiroshi ; KOISHIKAWA, Tsunekichi ; ISHII, Tokuzo ; IRIE, Ryozaburo ; OHTA, Eiichi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2050-e2c51c8194f60d5fa8a60b4d27cdf2d27918129335d9813465996df026f19ca43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>1971</creationdate><toplevel>online_resources</toplevel><creatorcontrib>HAMADA, Hiroshi</creatorcontrib><creatorcontrib>KOISHIKAWA, Tsunekichi</creatorcontrib><creatorcontrib>ISHII, Tokuzo</creatorcontrib><creatorcontrib>IRIE, Ryozaburo</creatorcontrib><creatorcontrib>OHTA, Eiichi</creatorcontrib><collection>CrossRef</collection><jtitle>Nihon Chikusan Gakkaiho</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>HAMADA, Hiroshi</au><au>KOISHIKAWA, Tsunekichi</au><au>ISHII, Tokuzo</au><au>IRIE, Ryozaburo</au><au>OHTA, Eiichi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the relationship between the pipeline length, inside diameter, compressed air pressure and time required for raw milk transportation through polyethylene pipe on level land</atitle><jtitle>Nihon Chikusan Gakkaiho</jtitle><addtitle>Nihon Chikusan Gakkaiho</addtitle><date>1971</date><risdate>1971</risdate><volume>42</volume><issue>11</issue><spage>570</spage><epage>576</epage><pages>570-576</pages><issn>1346-907X</issn><eissn>1880-8255</eissn><abstract>1) To furnish technological basis for the design of equipments for level land transportation of raw milk, experiments were conducted by using water instead of raw milk and polyethylene pipeline with inside diameter of 0.029m. And, a theoretical analysis was conducted upon basis of that, at a time point when the water-flow came to an optional position of the pipeline the following equation is attainable; From above equation a theoretical formula was derived by approximate calculation as below. 2) The actually observed values of t well agreed with the values calculated from formula (5) when 0.03 was substituted for λ. 3) In case of raw milk transportation by means of polyethylene pipeline with inside diameter of 0.029m, the equipments could be designed upon basis of calculation by the same formula except for substituting 0.035 for λ.</abstract><pub>Japanese Society of Animal Science</pub><doi>10.2508/chikusan.42.570</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1346-907X
ispartof Nihon Chikusan Gakkaiho, 1971/11/25, Vol.42(11), pp.570-576
issn 1346-907X
1880-8255
language jpn
recordid cdi_crossref_primary_10_2508_chikusan_42_570
source Alma/SFX Local Collection
title On the relationship between the pipeline length, inside diameter, compressed air pressure and time required for raw milk transportation through polyethylene pipe on level land
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T03%3A56%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20relationship%20between%20the%20pipeline%20length,%20inside%20diameter,%20compressed%20air%20pressure%20and%20time%20required%20for%20raw%20milk%20transportation%20through%20polyethylene%20pipe%20on%20level%20land&rft.jtitle=Nihon%20Chikusan%20Gakkaiho&rft.au=HAMADA,%20Hiroshi&rft.date=1971&rft.volume=42&rft.issue=11&rft.spage=570&rft.epage=576&rft.pages=570-576&rft.issn=1346-907X&rft.eissn=1880-8255&rft_id=info:doi/10.2508/chikusan.42.570&rft_dat=%3Cjstage_cross%3Earticle_chikusan1924_42_11_42_11_570_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true