Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor

The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in L...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of water and land development 2020-09, p.146-152
Hauptverfasser: Kurek, Karolina, Bugajski, Piotr, Operacz, Agnieszka, Młyński, Dariusz, Wałęga, Andrzej
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 152
container_issue
container_start_page 146
container_title Journal of water and land development
container_volume
creator Kurek, Karolina
Bugajski, Piotr
Operacz, Agnieszka
Młyński, Dariusz
Wałęga, Andrzej
description The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in Lesser Poland, in Siepraw commune. The analysis was per-formed using the Weibull method for basic indicators of impurities, BOD5, CODCr and total suspended solids. Physico-chemical analyses of raw and treated wastewater, were carried out in the period from 2003 to 2014 (11 years). The research period included measured values of pollutions indicators in 38 samples of raw and treated sewage. For each of pollution indicators descriptive statistic, percentage reduction ( ) and treatment plant reliability factors (RF) were calculated. Aver-age reduction for BOD5 and TSS was on level equal 94%, only for COD the average reduction was lower and was on level 89%. The reliability values determined by Weibull method, were: 75% (BOD5), 90% (CODCr) and 89.5% (TSS). The relia-bility results have been lower than the presented by literature source, which means that work of wastewater treatment plant in Siepraw was not satisfied in 11 years of research.
doi_str_mv 10.24425/jwld.2020.134207
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_24425_jwld_2020_134207</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_24425_jwld_2020_134207</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2037-7256fd19c86ec133b2bc1657fc21220055d80e99d01db8395192254f949d4f0f3</originalsourceid><addsrcrecordid>eNpNkD1PwzAYhC0EElXpD2DzH0ixX9tJPKKKL6kIhrKwRI7zunFx48qxVPXf0w8Gbri74XTDQ8g9Z3OQEtTDZh-6OTBgcy4ksOqKTIDVopBKqOt__ZbMxnHDjhJcKsUn5HuFth9iiGtvTaAJgzetDz4faHR0xL1ZI80JTd7ikOkumKPvfe5p7pF-xq0PGX_ouxkGmg87pK2Px7XNMd2RG2fCiLO_nJKv56fV4rVYfry8LR6XhQUmqqICVbqOa1uXaLkQLbSWl6pyFjgAY0p1NUOtO8a7thZacQ2gpNNSd9IxJ6aEX35tiuOY0DW75LcmHRrOmjOf5sSnOfFpLnzELwneWaw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor</title><source>DOAJ Directory of Open Access Journals</source><source>Walter De Gruyter: Open Access Journals</source><source>EZB Electronic Journals Library</source><creator>Kurek, Karolina ; Bugajski, Piotr ; Operacz, Agnieszka ; Młyński, Dariusz ; Wałęga, Andrzej</creator><creatorcontrib>Kurek, Karolina ; Bugajski, Piotr ; Operacz, Agnieszka ; Młyński, Dariusz ; Wałęga, Andrzej</creatorcontrib><description>The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in Lesser Poland, in Siepraw commune. The analysis was per-formed using the Weibull method for basic indicators of impurities, BOD5, CODCr and total suspended solids. Physico-chemical analyses of raw and treated wastewater, were carried out in the period from 2003 to 2014 (11 years). The research period included measured values of pollutions indicators in 38 samples of raw and treated sewage. For each of pollution indicators descriptive statistic, percentage reduction ( ) and treatment plant reliability factors (RF) were calculated. Aver-age reduction for BOD5 and TSS was on level equal 94%, only for COD the average reduction was lower and was on level 89%. The reliability values determined by Weibull method, were: 75% (BOD5), 90% (CODCr) and 89.5% (TSS). The relia-bility results have been lower than the presented by literature source, which means that work of wastewater treatment plant in Siepraw was not satisfied in 11 years of research.</description><identifier>ISSN: 2083-4535</identifier><identifier>EISSN: 2083-4535</identifier><identifier>DOI: 10.24425/jwld.2020.134207</identifier><language>eng</language><ispartof>Journal of water and land development, 2020-09, p.146-152</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2037-7256fd19c86ec133b2bc1657fc21220055d80e99d01db8395192254f949d4f0f3</citedby><orcidid>0000-0002-1717-1661 ; 0000-0002-6891-7953</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27903,27904</link.rule.ids></links><search><creatorcontrib>Kurek, Karolina</creatorcontrib><creatorcontrib>Bugajski, Piotr</creatorcontrib><creatorcontrib>Operacz, Agnieszka</creatorcontrib><creatorcontrib>Młyński, Dariusz</creatorcontrib><creatorcontrib>Wałęga, Andrzej</creatorcontrib><title>Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor</title><title>Journal of water and land development</title><description>The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in Lesser Poland, in Siepraw commune. The analysis was per-formed using the Weibull method for basic indicators of impurities, BOD5, CODCr and total suspended solids. Physico-chemical analyses of raw and treated wastewater, were carried out in the period from 2003 to 2014 (11 years). The research period included measured values of pollutions indicators in 38 samples of raw and treated sewage. For each of pollution indicators descriptive statistic, percentage reduction ( ) and treatment plant reliability factors (RF) were calculated. Aver-age reduction for BOD5 and TSS was on level equal 94%, only for COD the average reduction was lower and was on level 89%. The reliability values determined by Weibull method, were: 75% (BOD5), 90% (CODCr) and 89.5% (TSS). The relia-bility results have been lower than the presented by literature source, which means that work of wastewater treatment plant in Siepraw was not satisfied in 11 years of research.</description><issn>2083-4535</issn><issn>2083-4535</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpNkD1PwzAYhC0EElXpD2DzH0ixX9tJPKKKL6kIhrKwRI7zunFx48qxVPXf0w8Gbri74XTDQ8g9Z3OQEtTDZh-6OTBgcy4ksOqKTIDVopBKqOt__ZbMxnHDjhJcKsUn5HuFth9iiGtvTaAJgzetDz4faHR0xL1ZI80JTd7ikOkumKPvfe5p7pF-xq0PGX_ouxkGmg87pK2Px7XNMd2RG2fCiLO_nJKv56fV4rVYfry8LR6XhQUmqqICVbqOa1uXaLkQLbSWl6pyFjgAY0p1NUOtO8a7thZacQ2gpNNSd9IxJ6aEX35tiuOY0DW75LcmHRrOmjOf5sSnOfFpLnzELwneWaw</recordid><startdate>20200930</startdate><enddate>20200930</enddate><creator>Kurek, Karolina</creator><creator>Bugajski, Piotr</creator><creator>Operacz, Agnieszka</creator><creator>Młyński, Dariusz</creator><creator>Wałęga, Andrzej</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-1717-1661</orcidid><orcidid>https://orcid.org/0000-0002-6891-7953</orcidid></search><sort><creationdate>20200930</creationdate><title>Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor</title><author>Kurek, Karolina ; Bugajski, Piotr ; Operacz, Agnieszka ; Młyński, Dariusz ; Wałęga, Andrzej</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2037-7256fd19c86ec133b2bc1657fc21220055d80e99d01db8395192254f949d4f0f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kurek, Karolina</creatorcontrib><creatorcontrib>Bugajski, Piotr</creatorcontrib><creatorcontrib>Operacz, Agnieszka</creatorcontrib><creatorcontrib>Młyński, Dariusz</creatorcontrib><creatorcontrib>Wałęga, Andrzej</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of water and land development</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kurek, Karolina</au><au>Bugajski, Piotr</au><au>Operacz, Agnieszka</au><au>Młyński, Dariusz</au><au>Wałęga, Andrzej</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor</atitle><jtitle>Journal of water and land development</jtitle><date>2020-09-30</date><risdate>2020</risdate><spage>146</spage><epage>152</epage><pages>146-152</pages><issn>2083-4535</issn><eissn>2083-4535</eissn><abstract>The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in Lesser Poland, in Siepraw commune. The analysis was per-formed using the Weibull method for basic indicators of impurities, BOD5, CODCr and total suspended solids. Physico-chemical analyses of raw and treated wastewater, were carried out in the period from 2003 to 2014 (11 years). The research period included measured values of pollutions indicators in 38 samples of raw and treated sewage. For each of pollution indicators descriptive statistic, percentage reduction ( ) and treatment plant reliability factors (RF) were calculated. Aver-age reduction for BOD5 and TSS was on level equal 94%, only for COD the average reduction was lower and was on level 89%. The reliability values determined by Weibull method, were: 75% (BOD5), 90% (CODCr) and 89.5% (TSS). The relia-bility results have been lower than the presented by literature source, which means that work of wastewater treatment plant in Siepraw was not satisfied in 11 years of research.</abstract><doi>10.24425/jwld.2020.134207</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-1717-1661</orcidid><orcidid>https://orcid.org/0000-0002-6891-7953</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2083-4535
ispartof Journal of water and land development, 2020-09, p.146-152
issn 2083-4535
2083-4535
language eng
recordid cdi_crossref_primary_10_24425_jwld_2020_134207
source DOAJ Directory of Open Access Journals; Walter De Gruyter: Open Access Journals; EZB Electronic Journals Library
title Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T20%3A40%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Technological%20reliability%20of%20sewage%20treatment%20plant%20with%20the%20Pomiltek%20Mann%20type%20bioreactor&rft.jtitle=Journal%20of%20water%20and%20land%20development&rft.au=Kurek,%20Karolina&rft.date=2020-09-30&rft.spage=146&rft.epage=152&rft.pages=146-152&rft.issn=2083-4535&rft.eissn=2083-4535&rft_id=info:doi/10.24425/jwld.2020.134207&rft_dat=%3Ccrossref%3E10_24425_jwld_2020_134207%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true