Development and Validation of Enantiomeric Purity of Montelukast by SFC Method on Amylose Based Stationary Phase

A new Supercritical fluid liquid chromatographic (SFC) method has been developed in normal-phase conditions for the determination of enantiomeric purity of Montelukast sodium (S,E)-2-(1-((1-3-(2-(7-chloroquinolin-2-yl)vinyl)phenyl)-3-(2-(2-hydroxypropan-2-yl)phenyl)propylthio)ethyl) cyclopropyl) ace...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of advances in chemistry 2013-10, Vol.12 (7), p.518-524
Hauptverfasser: Maddala, Vijaya Lakshmi, Ch, Kameswararao, Polisetty, Srinivasulu
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 524
container_issue 7
container_start_page 518
container_title Journal of advances in chemistry
container_volume 12
creator Maddala, Vijaya Lakshmi
Ch, Kameswararao
Polisetty, Srinivasulu
description A new Supercritical fluid liquid chromatographic (SFC) method has been developed in normal-phase conditions for the determination of enantiomeric purity of Montelukast sodium (S,E)-2-(1-((1-3-(2-(7-chloroquinolin-2-yl)vinyl)phenyl)-3-(2-(2-hydroxypropan-2-yl)phenyl)propylthio)ethyl) cyclopropyl) acetic acid (R-isomer) (Anti asthmatic drug) in bulk drugs and in dosage forms. The sample was screened on the analytical SFC to determine the best column for the separation. The screening conditions are Column: Chiralpak AS-H (250 mm x 4.6 mm, 5 μm) column using a mobile phase system containing Supercritical fluid (Co2) and 2-Propanol in the ratio (85:15% v/v). The mobile-phase compositions and the differences in separation capability of the method is noted. The resolution between two enantiomers is found to be greater than 1.5. The SFC method for the separation of enantiomers of Montelukast is proved Accurate, Precise, Linear and robust. Relative standard deviation of retention times and peak areas were better than 0.2% and 0.4%, respectively, for precision. 
doi_str_mv 10.24297/jac.v12i7.6704
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_24297_jac_v12i7_6704</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_24297_jac_v12i7_6704</sourcerecordid><originalsourceid>FETCH-crossref_primary_10_24297_jac_v12i7_67043</originalsourceid><addsrcrecordid>eNqVj0FLAzEUhINUsNSevb4_0O3bdOvWo9YWL4VCRbyF5-5bmppNliQt7L83XTx49TTDMDPwCfGQYyYL-VTOT1Rll1zqMnsssbgRY7mQ-WyF5efoj78T0xBOiCiXuCxWOBbdK1_YuK5lG4FsDR9kdE1ROwuugY0lm3zLXlewP3sd-2u8czayOX9TiPDVw2G7hh3Ho6shzZ7b3rjA8EKBazjE4Yx8D_tjSu7FbUMm8PRXJ2K-3byv32aVdyF4blTndZvqKkc1sKnEpgY2dWVb_H_xA4nOWd8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Development and Validation of Enantiomeric Purity of Montelukast by SFC Method on Amylose Based Stationary Phase</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Maddala, Vijaya Lakshmi ; Ch, Kameswararao ; Polisetty, Srinivasulu</creator><creatorcontrib>Maddala, Vijaya Lakshmi ; Ch, Kameswararao ; Polisetty, Srinivasulu</creatorcontrib><description>A new Supercritical fluid liquid chromatographic (SFC) method has been developed in normal-phase conditions for the determination of enantiomeric purity of Montelukast sodium (S,E)-2-(1-((1-3-(2-(7-chloroquinolin-2-yl)vinyl)phenyl)-3-(2-(2-hydroxypropan-2-yl)phenyl)propylthio)ethyl) cyclopropyl) acetic acid (R-isomer) (Anti asthmatic drug) in bulk drugs and in dosage forms. The sample was screened on the analytical SFC to determine the best column for the separation. The screening conditions are Column: Chiralpak AS-H (250 mm x 4.6 mm, 5 μm) column using a mobile phase system containing Supercritical fluid (Co2) and 2-Propanol in the ratio (85:15% v/v). The mobile-phase compositions and the differences in separation capability of the method is noted. The resolution between two enantiomers is found to be greater than 1.5. The SFC method for the separation of enantiomers of Montelukast is proved Accurate, Precise, Linear and robust. Relative standard deviation of retention times and peak areas were better than 0.2% and 0.4%, respectively, for precision. </description><identifier>ISSN: 2321-807X</identifier><identifier>EISSN: 2321-807X</identifier><identifier>DOI: 10.24297/jac.v12i7.6704</identifier><language>eng</language><ispartof>Journal of advances in chemistry, 2013-10, Vol.12 (7), p.518-524</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Maddala, Vijaya Lakshmi</creatorcontrib><creatorcontrib>Ch, Kameswararao</creatorcontrib><creatorcontrib>Polisetty, Srinivasulu</creatorcontrib><title>Development and Validation of Enantiomeric Purity of Montelukast by SFC Method on Amylose Based Stationary Phase</title><title>Journal of advances in chemistry</title><description>A new Supercritical fluid liquid chromatographic (SFC) method has been developed in normal-phase conditions for the determination of enantiomeric purity of Montelukast sodium (S,E)-2-(1-((1-3-(2-(7-chloroquinolin-2-yl)vinyl)phenyl)-3-(2-(2-hydroxypropan-2-yl)phenyl)propylthio)ethyl) cyclopropyl) acetic acid (R-isomer) (Anti asthmatic drug) in bulk drugs and in dosage forms. The sample was screened on the analytical SFC to determine the best column for the separation. The screening conditions are Column: Chiralpak AS-H (250 mm x 4.6 mm, 5 μm) column using a mobile phase system containing Supercritical fluid (Co2) and 2-Propanol in the ratio (85:15% v/v). The mobile-phase compositions and the differences in separation capability of the method is noted. The resolution between two enantiomers is found to be greater than 1.5. The SFC method for the separation of enantiomers of Montelukast is proved Accurate, Precise, Linear and robust. Relative standard deviation of retention times and peak areas were better than 0.2% and 0.4%, respectively, for precision. </description><issn>2321-807X</issn><issn>2321-807X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNqVj0FLAzEUhINUsNSevb4_0O3bdOvWo9YWL4VCRbyF5-5bmppNliQt7L83XTx49TTDMDPwCfGQYyYL-VTOT1Rll1zqMnsssbgRY7mQ-WyF5efoj78T0xBOiCiXuCxWOBbdK1_YuK5lG4FsDR9kdE1ROwuugY0lm3zLXlewP3sd-2u8czayOX9TiPDVw2G7hh3Ho6shzZ7b3rjA8EKBazjE4Yx8D_tjSu7FbUMm8PRXJ2K-3byv32aVdyF4blTndZvqKkc1sKnEpgY2dWVb_H_xA4nOWd8</recordid><startdate>20131015</startdate><enddate>20131015</enddate><creator>Maddala, Vijaya Lakshmi</creator><creator>Ch, Kameswararao</creator><creator>Polisetty, Srinivasulu</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20131015</creationdate><title>Development and Validation of Enantiomeric Purity of Montelukast by SFC Method on Amylose Based Stationary Phase</title><author>Maddala, Vijaya Lakshmi ; Ch, Kameswararao ; Polisetty, Srinivasulu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-crossref_primary_10_24297_jac_v12i7_67043</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Maddala, Vijaya Lakshmi</creatorcontrib><creatorcontrib>Ch, Kameswararao</creatorcontrib><creatorcontrib>Polisetty, Srinivasulu</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of advances in chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Maddala, Vijaya Lakshmi</au><au>Ch, Kameswararao</au><au>Polisetty, Srinivasulu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and Validation of Enantiomeric Purity of Montelukast by SFC Method on Amylose Based Stationary Phase</atitle><jtitle>Journal of advances in chemistry</jtitle><date>2013-10-15</date><risdate>2013</risdate><volume>12</volume><issue>7</issue><spage>518</spage><epage>524</epage><pages>518-524</pages><issn>2321-807X</issn><eissn>2321-807X</eissn><abstract>A new Supercritical fluid liquid chromatographic (SFC) method has been developed in normal-phase conditions for the determination of enantiomeric purity of Montelukast sodium (S,E)-2-(1-((1-3-(2-(7-chloroquinolin-2-yl)vinyl)phenyl)-3-(2-(2-hydroxypropan-2-yl)phenyl)propylthio)ethyl) cyclopropyl) acetic acid (R-isomer) (Anti asthmatic drug) in bulk drugs and in dosage forms. The sample was screened on the analytical SFC to determine the best column for the separation. The screening conditions are Column: Chiralpak AS-H (250 mm x 4.6 mm, 5 μm) column using a mobile phase system containing Supercritical fluid (Co2) and 2-Propanol in the ratio (85:15% v/v). The mobile-phase compositions and the differences in separation capability of the method is noted. The resolution between two enantiomers is found to be greater than 1.5. The SFC method for the separation of enantiomers of Montelukast is proved Accurate, Precise, Linear and robust. Relative standard deviation of retention times and peak areas were better than 0.2% and 0.4%, respectively, for precision. </abstract><doi>10.24297/jac.v12i7.6704</doi></addata></record>
fulltext fulltext
identifier ISSN: 2321-807X
ispartof Journal of advances in chemistry, 2013-10, Vol.12 (7), p.518-524
issn 2321-807X
2321-807X
language eng
recordid cdi_crossref_primary_10_24297_jac_v12i7_6704
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
title Development and Validation of Enantiomeric Purity of Montelukast by SFC Method on Amylose Based Stationary Phase
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T07%3A10%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20Validation%20of%20Enantiomeric%20Purity%20of%20Montelukast%20by%20SFC%20Method%20on%20Amylose%20Based%20Stationary%20Phase&rft.jtitle=Journal%20of%20advances%20in%20chemistry&rft.au=Maddala,%20Vijaya%20Lakshmi&rft.date=2013-10-15&rft.volume=12&rft.issue=7&rft.spage=518&rft.epage=524&rft.pages=518-524&rft.issn=2321-807X&rft.eissn=2321-807X&rft_id=info:doi/10.24297/jac.v12i7.6704&rft_dat=%3Ccrossref%3E10_24297_jac_v12i7_6704%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true