IMPACT OF NON-LINEAR SMALL POWER RECEIVERS ON LOW VOLTAGE NETWORK OPERATION CONDITIONS

The paper discusses the causes of distorted waveforms of currents and voltages in industrial electric power systems of low voltage. The ascending contribution of domestic and municipal customers, particularly office and as commercial as well as service and shopping centers where, non-linear loads an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RE&PQJ 2024-01, Vol.12 (6)
Hauptverfasser: Julian Wosik, Bogdan Miedzinski, Artur Kozlowski, Marian Kalus
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 6
container_start_page
container_title RE&PQJ
container_volume 12
creator Julian Wosik
Bogdan Miedzinski
Artur Kozlowski
Marian Kalus
description The paper discusses the causes of distorted waveforms of currents and voltages in industrial electric power systems of low voltage. The ascending contribution of domestic and municipal customers, particularly office and as commercial as well as service and shopping centers where, non-linear loads and load phase unbalance are common, is indicated. Studies of voltage and current waveforms and their harmonics spectra at selected this type of facilities were carried out. The ability to compensate for the negative impact of low power consumer receivers using the active power filter has been demonstrated.
doi_str_mv 10.24084/repqj12.454
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_24084_repqj12_454</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_24084_repqj12_454</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1454-a1f8a72ccb3e730e104ffe93f39ecb749fe029574237db13bcdba9955ddb63f93</originalsourceid><addsrcrecordid>eNpNkM1KxDAAhIMouKx78wHyAHbNX39yLDW7BrNJaWvrrTRpAiuKa3vy7a26B0_zwcDMMADcYrQlDGXsfvKnz1dMtixmF2BFcEoiRLOXy398DTbzfLSIJQnJMCcr0MpDmRcNNDuojY6U1CKvYH3IlYKl6UQFK1EI2YqqhkZDZTrYGtXkewG1aDpTPUFTiipv5OIWRj_IH6pvwFUY3ma_OesaPO9EUzxGyuxlkavI4WVmNOCQDSlxzlKfUuQxYiF4TgPl3tmU8eAR4XHKCE1Hi6l1ox04j-NxtAkNnK7B3V-umz7mefKhP03H92H66jHqf2_pz7f0Sx_9BuVmT8A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>IMPACT OF NON-LINEAR SMALL POWER RECEIVERS ON LOW VOLTAGE NETWORK OPERATION CONDITIONS</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Julian Wosik ; Bogdan Miedzinski ; Artur Kozlowski ; Marian Kalus</creator><creatorcontrib>Julian Wosik ; Bogdan Miedzinski ; Artur Kozlowski ; Marian Kalus</creatorcontrib><description>The paper discusses the causes of distorted waveforms of currents and voltages in industrial electric power systems of low voltage. The ascending contribution of domestic and municipal customers, particularly office and as commercial as well as service and shopping centers where, non-linear loads and load phase unbalance are common, is indicated. Studies of voltage and current waveforms and their harmonics spectra at selected this type of facilities were carried out. The ability to compensate for the negative impact of low power consumer receivers using the active power filter has been demonstrated.</description><identifier>ISSN: 2172-038X</identifier><identifier>EISSN: 2172-038X</identifier><identifier>DOI: 10.24084/repqj12.454</identifier><language>eng</language><ispartof>RE&amp;PQJ, 2024-01, Vol.12 (6)</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Julian Wosik</creatorcontrib><creatorcontrib>Bogdan Miedzinski</creatorcontrib><creatorcontrib>Artur Kozlowski</creatorcontrib><creatorcontrib>Marian Kalus</creatorcontrib><title>IMPACT OF NON-LINEAR SMALL POWER RECEIVERS ON LOW VOLTAGE NETWORK OPERATION CONDITIONS</title><title>RE&amp;PQJ</title><description>The paper discusses the causes of distorted waveforms of currents and voltages in industrial electric power systems of low voltage. The ascending contribution of domestic and municipal customers, particularly office and as commercial as well as service and shopping centers where, non-linear loads and load phase unbalance are common, is indicated. Studies of voltage and current waveforms and their harmonics spectra at selected this type of facilities were carried out. The ability to compensate for the negative impact of low power consumer receivers using the active power filter has been demonstrated.</description><issn>2172-038X</issn><issn>2172-038X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpNkM1KxDAAhIMouKx78wHyAHbNX39yLDW7BrNJaWvrrTRpAiuKa3vy7a26B0_zwcDMMADcYrQlDGXsfvKnz1dMtixmF2BFcEoiRLOXy398DTbzfLSIJQnJMCcr0MpDmRcNNDuojY6U1CKvYH3IlYKl6UQFK1EI2YqqhkZDZTrYGtXkewG1aDpTPUFTiipv5OIWRj_IH6pvwFUY3ma_OesaPO9EUzxGyuxlkavI4WVmNOCQDSlxzlKfUuQxYiF4TgPl3tmU8eAR4XHKCE1Hi6l1ox04j-NxtAkNnK7B3V-umz7mefKhP03H92H66jHqf2_pz7f0Sx_9BuVmT8A</recordid><startdate>20240124</startdate><enddate>20240124</enddate><creator>Julian Wosik</creator><creator>Bogdan Miedzinski</creator><creator>Artur Kozlowski</creator><creator>Marian Kalus</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20240124</creationdate><title>IMPACT OF NON-LINEAR SMALL POWER RECEIVERS ON LOW VOLTAGE NETWORK OPERATION CONDITIONS</title><author>Julian Wosik ; Bogdan Miedzinski ; Artur Kozlowski ; Marian Kalus</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1454-a1f8a72ccb3e730e104ffe93f39ecb749fe029574237db13bcdba9955ddb63f93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Julian Wosik</creatorcontrib><creatorcontrib>Bogdan Miedzinski</creatorcontrib><creatorcontrib>Artur Kozlowski</creatorcontrib><creatorcontrib>Marian Kalus</creatorcontrib><collection>CrossRef</collection><jtitle>RE&amp;PQJ</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Julian Wosik</au><au>Bogdan Miedzinski</au><au>Artur Kozlowski</au><au>Marian Kalus</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>IMPACT OF NON-LINEAR SMALL POWER RECEIVERS ON LOW VOLTAGE NETWORK OPERATION CONDITIONS</atitle><jtitle>RE&amp;PQJ</jtitle><date>2024-01-24</date><risdate>2024</risdate><volume>12</volume><issue>6</issue><issn>2172-038X</issn><eissn>2172-038X</eissn><abstract>The paper discusses the causes of distorted waveforms of currents and voltages in industrial electric power systems of low voltage. The ascending contribution of domestic and municipal customers, particularly office and as commercial as well as service and shopping centers where, non-linear loads and load phase unbalance are common, is indicated. Studies of voltage and current waveforms and their harmonics spectra at selected this type of facilities were carried out. The ability to compensate for the negative impact of low power consumer receivers using the active power filter has been demonstrated.</abstract><doi>10.24084/repqj12.454</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2172-038X
ispartof RE&PQJ, 2024-01, Vol.12 (6)
issn 2172-038X
2172-038X
language eng
recordid cdi_crossref_primary_10_24084_repqj12_454
source EZB-FREE-00999 freely available EZB journals
title IMPACT OF NON-LINEAR SMALL POWER RECEIVERS ON LOW VOLTAGE NETWORK OPERATION CONDITIONS
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T15%3A47%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=IMPACT%20OF%20NON-LINEAR%20SMALL%20POWER%20RECEIVERS%20ON%20LOW%20VOLTAGE%20NETWORK%20OPERATION%20CONDITIONS&rft.jtitle=RE&PQJ&rft.au=Julian%20Wosik&rft.date=2024-01-24&rft.volume=12&rft.issue=6&rft.issn=2172-038X&rft.eissn=2172-038X&rft_id=info:doi/10.24084/repqj12.454&rft_dat=%3Ccrossref%3E10_24084_repqj12_454%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true