Analysis of a single phase inverter for photovoltaic systems operating in a weak electric grid

Single-phase inverters for photovoltaic systems are normally analyzed when they are connected to the strong electric grid with low impedance. This work focuses on analysis of a single-phase inverter operating in a weak electric grid with relatively high impedance. Presented are experimentally determ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RE&PQJ 2024-01, Vol.6 (1)
Hauptverfasser: Gorazd Štumberger, Sebastijan Seme, Klemen Deželak, Andrej Hanžič, Jože Voršič
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title RE&PQJ
container_volume 6
creator Gorazd Štumberger
Sebastijan Seme
Klemen Deželak
Andrej Hanžič
Jože Voršič
description Single-phase inverters for photovoltaic systems are normally analyzed when they are connected to the strong electric grid with low impedance. This work focuses on analysis of a single-phase inverter operating in a weak electric grid with relatively high impedance. Presented are experimentally determined results for the inverter’s efficiency, voltage and current total harmonic distortion and power factor. The results presented show substantial contents of sub harmonic components in the inverter’s output current.
doi_str_mv 10.24084/repqj06.282
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_24084_repqj06_282</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_24084_repqj06_282</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1452-7ecb97c2577f326dd812e9c47bd3c5d94b8724580e740aeb1cdd8ff1349ceb713</originalsourceid><addsrcrecordid>eNpNkMtKAzEUQIMoWGp3fkA-wKl5zSSzLMVHoeBGwZVDkrmp0elkTEKlf2_QLlzdy-WcuzgIXVOyZIIocRth-vogzZIpdoZmjEpWEa5ez__tl2iRkjdENA1TtGUz9LYa9XBMPuHgsMbJj7sB8PSuE2A_HiBmiNiFWE4hh0MYsvYWp2PKsC_OBFHn4hS22N-gPzEMYHMs0C76_gpdOD0kWJzmHL3c3z2vH6vt08NmvdpWloqaVRKsaaVltZSOs6bvFWXQWiFNz23dt8IoyUStCEhBNBhqC-Ic5aK1YCTlc3Tz99fGkFIE103R73U8dpR0v3m6U56u5OE_q9JbGg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Analysis of a single phase inverter for photovoltaic systems operating in a weak electric grid</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Gorazd Štumberger ; Sebastijan Seme ; Klemen Deželak ; Andrej Hanžič ; Jože Voršič</creator><creatorcontrib>Gorazd Štumberger ; Sebastijan Seme ; Klemen Deželak ; Andrej Hanžič ; Jože Voršič</creatorcontrib><description>Single-phase inverters for photovoltaic systems are normally analyzed when they are connected to the strong electric grid with low impedance. This work focuses on analysis of a single-phase inverter operating in a weak electric grid with relatively high impedance. Presented are experimentally determined results for the inverter’s efficiency, voltage and current total harmonic distortion and power factor. The results presented show substantial contents of sub harmonic components in the inverter’s output current.</description><identifier>ISSN: 2172-038X</identifier><identifier>EISSN: 2172-038X</identifier><identifier>DOI: 10.24084/repqj06.282</identifier><language>eng</language><ispartof>RE&amp;PQJ, 2024-01, Vol.6 (1)</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Gorazd Štumberger</creatorcontrib><creatorcontrib>Sebastijan Seme</creatorcontrib><creatorcontrib>Klemen Deželak</creatorcontrib><creatorcontrib>Andrej Hanžič</creatorcontrib><creatorcontrib>Jože Voršič</creatorcontrib><title>Analysis of a single phase inverter for photovoltaic systems operating in a weak electric grid</title><title>RE&amp;PQJ</title><description>Single-phase inverters for photovoltaic systems are normally analyzed when they are connected to the strong electric grid with low impedance. This work focuses on analysis of a single-phase inverter operating in a weak electric grid with relatively high impedance. Presented are experimentally determined results for the inverter’s efficiency, voltage and current total harmonic distortion and power factor. The results presented show substantial contents of sub harmonic components in the inverter’s output current.</description><issn>2172-038X</issn><issn>2172-038X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpNkMtKAzEUQIMoWGp3fkA-wKl5zSSzLMVHoeBGwZVDkrmp0elkTEKlf2_QLlzdy-WcuzgIXVOyZIIocRth-vogzZIpdoZmjEpWEa5ez__tl2iRkjdENA1TtGUz9LYa9XBMPuHgsMbJj7sB8PSuE2A_HiBmiNiFWE4hh0MYsvYWp2PKsC_OBFHn4hS22N-gPzEMYHMs0C76_gpdOD0kWJzmHL3c3z2vH6vt08NmvdpWloqaVRKsaaVltZSOs6bvFWXQWiFNz23dt8IoyUStCEhBNBhqC-Ic5aK1YCTlc3Tz99fGkFIE103R73U8dpR0v3m6U56u5OE_q9JbGg</recordid><startdate>20240115</startdate><enddate>20240115</enddate><creator>Gorazd Štumberger</creator><creator>Sebastijan Seme</creator><creator>Klemen Deželak</creator><creator>Andrej Hanžič</creator><creator>Jože Voršič</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20240115</creationdate><title>Analysis of a single phase inverter for photovoltaic systems operating in a weak electric grid</title><author>Gorazd Štumberger ; Sebastijan Seme ; Klemen Deželak ; Andrej Hanžič ; Jože Voršič</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1452-7ecb97c2577f326dd812e9c47bd3c5d94b8724580e740aeb1cdd8ff1349ceb713</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Gorazd Štumberger</creatorcontrib><creatorcontrib>Sebastijan Seme</creatorcontrib><creatorcontrib>Klemen Deželak</creatorcontrib><creatorcontrib>Andrej Hanžič</creatorcontrib><creatorcontrib>Jože Voršič</creatorcontrib><collection>CrossRef</collection><jtitle>RE&amp;PQJ</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gorazd Štumberger</au><au>Sebastijan Seme</au><au>Klemen Deželak</au><au>Andrej Hanžič</au><au>Jože Voršič</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of a single phase inverter for photovoltaic systems operating in a weak electric grid</atitle><jtitle>RE&amp;PQJ</jtitle><date>2024-01-15</date><risdate>2024</risdate><volume>6</volume><issue>1</issue><issn>2172-038X</issn><eissn>2172-038X</eissn><abstract>Single-phase inverters for photovoltaic systems are normally analyzed when they are connected to the strong electric grid with low impedance. This work focuses on analysis of a single-phase inverter operating in a weak electric grid with relatively high impedance. Presented are experimentally determined results for the inverter’s efficiency, voltage and current total harmonic distortion and power factor. The results presented show substantial contents of sub harmonic components in the inverter’s output current.</abstract><doi>10.24084/repqj06.282</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2172-038X
ispartof RE&PQJ, 2024-01, Vol.6 (1)
issn 2172-038X
2172-038X
language eng
recordid cdi_crossref_primary_10_24084_repqj06_282
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
title Analysis of a single phase inverter for photovoltaic systems operating in a weak electric grid
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T12%3A22%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20a%20single%20phase%20inverter%20for%20photovoltaic%20systems%20operating%20in%20a%20weak%20electric%20grid&rft.jtitle=RE&PQJ&rft.au=Gorazd%20%C5%A0tumberger&rft.date=2024-01-15&rft.volume=6&rft.issue=1&rft.issn=2172-038X&rft.eissn=2172-038X&rft_id=info:doi/10.24084/repqj06.282&rft_dat=%3Ccrossref%3E10_24084_repqj06_282%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true