DEVELOPMENT AND VALIDATION OF NEW RP-UPLC METHOD FOR THE DETERMINATION OF CEFDINIR IN BULK AND DOSAGE FORM

Objective: The objective of the study was to develop and validate a new rapid and sensitive reverse phase ultra-performance liquid chromatographic (RP-UPLC) method for determination of cefdinir in bulk drug and dosage form.Methods: Separation was achieved with an Acquity SB C18 (100 × 2 mm) 1.8μm co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of pharmacy and pharmaceutical sciences 2018-01, Vol.10 (1), p.178
Hauptverfasser: Ponnekanti, Krishnaphanisri, Sundararajan, Raja
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 178
container_title International journal of pharmacy and pharmaceutical sciences
container_volume 10
creator Ponnekanti, Krishnaphanisri
Sundararajan, Raja
description Objective: The objective of the study was to develop and validate a new rapid and sensitive reverse phase ultra-performance liquid chromatographic (RP-UPLC) method for determination of cefdinir in bulk drug and dosage form.Methods: Separation was achieved with an Acquity SB C18 (100 × 2 mm) 1.8μm column with an isocratic mobile phase containing a mixture of orthophosphoric acid and acetonitrile (60:40 v/v) and pH adjusted to 2.8. The flow rate of the mobile phase was 0.3 ml/min with a column temperature of 30 °C and detection wavelength at 285 nm.Results: The method was validated with respect to linearity, accuracy, precision, detection limits, robustness and specificity. The precision of the results, stated as the relative standard deviation was below 1.5%. The calibration curve was linear over a concentration range from 25 to 150μg/ml with a correlation coefficient of 0.9993. The accuracy of the method demonstrated at three levels in the range of 50%, 100% and 150% of the specification limit. The recovery of cefdinir was found to be in the range of 98 to 102%, whereas the detection limits were found to be 0.17 and 0.51µg/ml. Forced degradation study was carried out under acidic, alkaline, oxidative, photolytic and thermal conditions to prove the stability-indicating ability of the developed UPLC method.Conclusion: The developed method was validated with respect to linearity, accuracy, precision limit of detection and quantification, robustness and specificity. The method was applied successfully for the determination of cefdinir in tablets.
doi_str_mv 10.22159/ijpps.2018v10i1.23256
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_22159_ijpps_2018v10i1_23256</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_22159_ijpps_2018v10i1_23256</sourcerecordid><originalsourceid>FETCH-crossref_primary_10_22159_ijpps_2018v10i1_232563</originalsourceid><addsrcrecordid>eNqdj0FrwkAUhJdioWL9C_L-QNJ9G6PmmGZfmqXJbkhXPS5SFBJaGrJQ6L_XBpGeO5eZw8zAx9gCeSgExslT2_W9DwXHzTfyFkMRiXh1x6Y8WccBLhOc_MkPbO59xy9acoE8mrJO0o5KU1ekLaRawi4tlUytMhpMDpr20NTBti4zqMgWRkJuGrAFgSRLTaX0rZtRLpVWDSgNz9vydbyT5i19od9R9cjuT4cPf5xffcZWOdmsCN6HL--H48n1Q_t5GH4ccjfCuRHO3eDcCBf9e3gGhnpSfA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>DEVELOPMENT AND VALIDATION OF NEW RP-UPLC METHOD FOR THE DETERMINATION OF CEFDINIR IN BULK AND DOSAGE FORM</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Ponnekanti, Krishnaphanisri ; Sundararajan, Raja</creator><creatorcontrib>Ponnekanti, Krishnaphanisri ; Sundararajan, Raja</creatorcontrib><description>Objective: The objective of the study was to develop and validate a new rapid and sensitive reverse phase ultra-performance liquid chromatographic (RP-UPLC) method for determination of cefdinir in bulk drug and dosage form.Methods: Separation was achieved with an Acquity SB C18 (100 × 2 mm) 1.8μm column with an isocratic mobile phase containing a mixture of orthophosphoric acid and acetonitrile (60:40 v/v) and pH adjusted to 2.8. The flow rate of the mobile phase was 0.3 ml/min with a column temperature of 30 °C and detection wavelength at 285 nm.Results: The method was validated with respect to linearity, accuracy, precision, detection limits, robustness and specificity. The precision of the results, stated as the relative standard deviation was below 1.5%. The calibration curve was linear over a concentration range from 25 to 150μg/ml with a correlation coefficient of 0.9993. The accuracy of the method demonstrated at three levels in the range of 50%, 100% and 150% of the specification limit. The recovery of cefdinir was found to be in the range of 98 to 102%, whereas the detection limits were found to be 0.17 and 0.51µg/ml. Forced degradation study was carried out under acidic, alkaline, oxidative, photolytic and thermal conditions to prove the stability-indicating ability of the developed UPLC method.Conclusion: The developed method was validated with respect to linearity, accuracy, precision limit of detection and quantification, robustness and specificity. The method was applied successfully for the determination of cefdinir in tablets.</description><identifier>ISSN: 0975-1491</identifier><identifier>EISSN: 0975-1491</identifier><identifier>DOI: 10.22159/ijpps.2018v10i1.23256</identifier><language>eng</language><ispartof>International journal of pharmacy and pharmaceutical sciences, 2018-01, Vol.10 (1), p.178</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Ponnekanti, Krishnaphanisri</creatorcontrib><creatorcontrib>Sundararajan, Raja</creatorcontrib><title>DEVELOPMENT AND VALIDATION OF NEW RP-UPLC METHOD FOR THE DETERMINATION OF CEFDINIR IN BULK AND DOSAGE FORM</title><title>International journal of pharmacy and pharmaceutical sciences</title><description>Objective: The objective of the study was to develop and validate a new rapid and sensitive reverse phase ultra-performance liquid chromatographic (RP-UPLC) method for determination of cefdinir in bulk drug and dosage form.Methods: Separation was achieved with an Acquity SB C18 (100 × 2 mm) 1.8μm column with an isocratic mobile phase containing a mixture of orthophosphoric acid and acetonitrile (60:40 v/v) and pH adjusted to 2.8. The flow rate of the mobile phase was 0.3 ml/min with a column temperature of 30 °C and detection wavelength at 285 nm.Results: The method was validated with respect to linearity, accuracy, precision, detection limits, robustness and specificity. The precision of the results, stated as the relative standard deviation was below 1.5%. The calibration curve was linear over a concentration range from 25 to 150μg/ml with a correlation coefficient of 0.9993. The accuracy of the method demonstrated at three levels in the range of 50%, 100% and 150% of the specification limit. The recovery of cefdinir was found to be in the range of 98 to 102%, whereas the detection limits were found to be 0.17 and 0.51µg/ml. Forced degradation study was carried out under acidic, alkaline, oxidative, photolytic and thermal conditions to prove the stability-indicating ability of the developed UPLC method.Conclusion: The developed method was validated with respect to linearity, accuracy, precision limit of detection and quantification, robustness and specificity. The method was applied successfully for the determination of cefdinir in tablets.</description><issn>0975-1491</issn><issn>0975-1491</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqdj0FrwkAUhJdioWL9C_L-QNJ9G6PmmGZfmqXJbkhXPS5SFBJaGrJQ6L_XBpGeO5eZw8zAx9gCeSgExslT2_W9DwXHzTfyFkMRiXh1x6Y8WccBLhOc_MkPbO59xy9acoE8mrJO0o5KU1ekLaRawi4tlUytMhpMDpr20NTBti4zqMgWRkJuGrAFgSRLTaX0rZtRLpVWDSgNz9vydbyT5i19od9R9cjuT4cPf5xffcZWOdmsCN6HL--H48n1Q_t5GH4ccjfCuRHO3eDcCBf9e3gGhnpSfA</recordid><startdate>20180101</startdate><enddate>20180101</enddate><creator>Ponnekanti, Krishnaphanisri</creator><creator>Sundararajan, Raja</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20180101</creationdate><title>DEVELOPMENT AND VALIDATION OF NEW RP-UPLC METHOD FOR THE DETERMINATION OF CEFDINIR IN BULK AND DOSAGE FORM</title><author>Ponnekanti, Krishnaphanisri ; Sundararajan, Raja</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-crossref_primary_10_22159_ijpps_2018v10i1_232563</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Ponnekanti, Krishnaphanisri</creatorcontrib><creatorcontrib>Sundararajan, Raja</creatorcontrib><collection>CrossRef</collection><jtitle>International journal of pharmacy and pharmaceutical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ponnekanti, Krishnaphanisri</au><au>Sundararajan, Raja</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>DEVELOPMENT AND VALIDATION OF NEW RP-UPLC METHOD FOR THE DETERMINATION OF CEFDINIR IN BULK AND DOSAGE FORM</atitle><jtitle>International journal of pharmacy and pharmaceutical sciences</jtitle><date>2018-01-01</date><risdate>2018</risdate><volume>10</volume><issue>1</issue><spage>178</spage><pages>178-</pages><issn>0975-1491</issn><eissn>0975-1491</eissn><abstract>Objective: The objective of the study was to develop and validate a new rapid and sensitive reverse phase ultra-performance liquid chromatographic (RP-UPLC) method for determination of cefdinir in bulk drug and dosage form.Methods: Separation was achieved with an Acquity SB C18 (100 × 2 mm) 1.8μm column with an isocratic mobile phase containing a mixture of orthophosphoric acid and acetonitrile (60:40 v/v) and pH adjusted to 2.8. The flow rate of the mobile phase was 0.3 ml/min with a column temperature of 30 °C and detection wavelength at 285 nm.Results: The method was validated with respect to linearity, accuracy, precision, detection limits, robustness and specificity. The precision of the results, stated as the relative standard deviation was below 1.5%. The calibration curve was linear over a concentration range from 25 to 150μg/ml with a correlation coefficient of 0.9993. The accuracy of the method demonstrated at three levels in the range of 50%, 100% and 150% of the specification limit. The recovery of cefdinir was found to be in the range of 98 to 102%, whereas the detection limits were found to be 0.17 and 0.51µg/ml. Forced degradation study was carried out under acidic, alkaline, oxidative, photolytic and thermal conditions to prove the stability-indicating ability of the developed UPLC method.Conclusion: The developed method was validated with respect to linearity, accuracy, precision limit of detection and quantification, robustness and specificity. The method was applied successfully for the determination of cefdinir in tablets.</abstract><doi>10.22159/ijpps.2018v10i1.23256</doi></addata></record>
fulltext fulltext
identifier ISSN: 0975-1491
ispartof International journal of pharmacy and pharmaceutical sciences, 2018-01, Vol.10 (1), p.178
issn 0975-1491
0975-1491
language eng
recordid cdi_crossref_primary_10_22159_ijpps_2018v10i1_23256
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
title DEVELOPMENT AND VALIDATION OF NEW RP-UPLC METHOD FOR THE DETERMINATION OF CEFDINIR IN BULK AND DOSAGE FORM
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T21%3A01%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=DEVELOPMENT%20AND%20VALIDATION%20OF%20NEW%20RP-UPLC%20METHOD%20FOR%20THE%20DETERMINATION%20OF%20CEFDINIR%20IN%20BULK%20AND%20DOSAGE%20FORM&rft.jtitle=International%20journal%20of%20pharmacy%20and%20pharmaceutical%20sciences&rft.au=Ponnekanti,%20Krishnaphanisri&rft.date=2018-01-01&rft.volume=10&rft.issue=1&rft.spage=178&rft.pages=178-&rft.issn=0975-1491&rft.eissn=0975-1491&rft_id=info:doi/10.22159/ijpps.2018v10i1.23256&rft_dat=%3Ccrossref%3E10_22159_ijpps_2018v10i1_23256%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true