Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography

The objective of our study was to evaluate whether the SD of CT attenuation values obtained from unenhanced scans of the left atrium is a reliable parameter for the individual modulation of tube current to achieve uniform image quality in coronary CT angiography (CTA). One hundred patients (59 men a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2007-07, Vol.189 (1), p.188-196
Hauptverfasser: Hur, Gham, Hong, Seong Wan, Kim, Su Young, Kim, Yong Hoon, Hwang, Yoon Joon, Lee, Won Ro, Cha, Soon Joo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 196
container_issue 1
container_start_page 188
container_title American journal of roentgenology (1976)
container_volume 189
creator Hur, Gham
Hong, Seong Wan
Kim, Su Young
Kim, Yong Hoon
Hwang, Yoon Joon
Lee, Won Ro
Cha, Soon Joo
description The objective of our study was to evaluate whether the SD of CT attenuation values obtained from unenhanced scans of the left atrium is a reliable parameter for the individual modulation of tube current to achieve uniform image quality in coronary CT angiography (CTA). One hundred patients (59 men and 41 women) who were suspected to have coronary artery disease underwent coronary CTA using a 64-MDCT scanner. In addition to clinical studies, we also performed measurements on water phantoms. Tube current was modulated by the SD of the CT attenuation values measured from the left atrium on unenhanced images scanned at 300 mA. A modulation table was created from data obtained from the studies of water phantoms scanned at various tube currents. Other scanning parameters were identical to those used to obtain unenhanced and contrast-enhanced studies of the 100 patients. The SD values were measured from images scanned at an adjusted tube current, and the images of normal coronary and internal mammary arteries were graded. Radiation doses measured using the volume CT dose index (CTDI(vol)) were compared between the SD of the CT attenuation values and the modulation parameters suggested by the manufacturer of the scanner. Image quality was rated as grade 3 (low mottle) on a 4-grade scale by four observers for 92-94 of the 100 patients (average, 92.5%). The mean SD value at an adjusted tube current was 12.1 H with an SD of 0.758 H (target SD = 12 H). A radiation dose reduction of 9-45% was achieved in patients grouped by weight who weighed less than 70 kg, and a reduction of up to 71% was seen in individual cases. Modulating tube current using the SD of CT attenuation values from the left atrium is a highly reliable method of achieving uniform image quality in coronary CTA.
doi_str_mv 10.2214/AJR.06.1201
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_2214_AJR_06_1201</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>17579170</sourcerecordid><originalsourceid>FETCH-LOGICAL-c348t-de61b061360e075407522ceb782f8ccdf42dff4991e70674e063fed11e0363f63</originalsourceid><addsrcrecordid>eNpF0E2L2zAQBmBRWrrZbU-9F13ay-J0xnIk-2jcry1bStsEehOyPXJUbDlIdkP-fR0S2MMwMDwMMy9jbxDWaYrZh_LbrzXINaaAz9gKN5lMBGb4nK1ASExyEH9u2G2MfwFA5YV6yW5QbVSBClas33lnxzDwh8F0xH_OpnfTiZfN3tE_anl94tu5Jl7NIZCf-PexnXszudHzXXS-478_8tHycprIz5e587waw-hNOPFqy0vfubEL5rA_vWIvrOkjvb72O7b7_GlbfU0ef3x5qMrHpBFZPiUtSaxBopBAoDbZUmnaUK3y1OZN09osba3NigJJgVQZgRSWWkRaHhZWijt2f9nbhDHGQFYfghuWezSCPmeml8w0SH3ObNFvL_ow1wO1T_Ya0gLeXYGJjeltML5x8cnluYS0EIt7f3F71-2PLpCOg-n7ZS3q4_GIeaHxrMV_FMWA9Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography</title><source>American Roentgen Ray Society</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Hur, Gham ; Hong, Seong Wan ; Kim, Su Young ; Kim, Yong Hoon ; Hwang, Yoon Joon ; Lee, Won Ro ; Cha, Soon Joo</creator><creatorcontrib>Hur, Gham ; Hong, Seong Wan ; Kim, Su Young ; Kim, Yong Hoon ; Hwang, Yoon Joon ; Lee, Won Ro ; Cha, Soon Joo</creatorcontrib><description>The objective of our study was to evaluate whether the SD of CT attenuation values obtained from unenhanced scans of the left atrium is a reliable parameter for the individual modulation of tube current to achieve uniform image quality in coronary CT angiography (CTA). One hundred patients (59 men and 41 women) who were suspected to have coronary artery disease underwent coronary CTA using a 64-MDCT scanner. In addition to clinical studies, we also performed measurements on water phantoms. Tube current was modulated by the SD of the CT attenuation values measured from the left atrium on unenhanced images scanned at 300 mA. A modulation table was created from data obtained from the studies of water phantoms scanned at various tube currents. Other scanning parameters were identical to those used to obtain unenhanced and contrast-enhanced studies of the 100 patients. The SD values were measured from images scanned at an adjusted tube current, and the images of normal coronary and internal mammary arteries were graded. Radiation doses measured using the volume CT dose index (CTDI(vol)) were compared between the SD of the CT attenuation values and the modulation parameters suggested by the manufacturer of the scanner. Image quality was rated as grade 3 (low mottle) on a 4-grade scale by four observers for 92-94 of the 100 patients (average, 92.5%). The mean SD value at an adjusted tube current was 12.1 H with an SD of 0.758 H (target SD = 12 H). A radiation dose reduction of 9-45% was achieved in patients grouped by weight who weighed less than 70 kg, and a reduction of up to 71% was seen in individual cases. Modulating tube current using the SD of CT attenuation values from the left atrium is a highly reliable method of achieving uniform image quality in coronary CTA.</description><identifier>ISSN: 0361-803X</identifier><identifier>EISSN: 1546-3141</identifier><identifier>DOI: 10.2214/AJR.06.1201</identifier><identifier>PMID: 17579170</identifier><identifier>CODEN: AAJRDX</identifier><language>eng</language><publisher>Leesburg, VA: Am Roentgen Ray Soc</publisher><subject>Applied radiobiology (equipment, dosimetry...) ; Biological and medical sciences ; Biological effects of radiation ; Cardiology. Vascular system ; Cardiovascular system ; Coronary Angiography - methods ; Coronary Artery Disease - diagnostic imaging ; Coronary heart disease ; Female ; Fundamental and applied biological sciences. Psychology ; Heart ; Heart Atria - diagnostic imaging ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Medical sciences ; Middle Aged ; Radiation Dosage ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Radiographic Image Enhancement - methods ; Radiographic Image Interpretation, Computer-Assisted - methods ; Reproducibility of Results ; Sensitivity and Specificity ; Tissues, organs and organisms biophysics ; Tomography, X-Ray Computed - methods</subject><ispartof>American journal of roentgenology (1976), 2007-07, Vol.189 (1), p.188-196</ispartof><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c348t-de61b061360e075407522ceb782f8ccdf42dff4991e70674e063fed11e0363f63</citedby><cites>FETCH-LOGICAL-c348t-de61b061360e075407522ceb782f8ccdf42dff4991e70674e063fed11e0363f63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4120,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=18860293$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17579170$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hur, Gham</creatorcontrib><creatorcontrib>Hong, Seong Wan</creatorcontrib><creatorcontrib>Kim, Su Young</creatorcontrib><creatorcontrib>Kim, Yong Hoon</creatorcontrib><creatorcontrib>Hwang, Yoon Joon</creatorcontrib><creatorcontrib>Lee, Won Ro</creatorcontrib><creatorcontrib>Cha, Soon Joo</creatorcontrib><title>Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography</title><title>American journal of roentgenology (1976)</title><addtitle>AJR Am J Roentgenol</addtitle><description>The objective of our study was to evaluate whether the SD of CT attenuation values obtained from unenhanced scans of the left atrium is a reliable parameter for the individual modulation of tube current to achieve uniform image quality in coronary CT angiography (CTA). One hundred patients (59 men and 41 women) who were suspected to have coronary artery disease underwent coronary CTA using a 64-MDCT scanner. In addition to clinical studies, we also performed measurements on water phantoms. Tube current was modulated by the SD of the CT attenuation values measured from the left atrium on unenhanced images scanned at 300 mA. A modulation table was created from data obtained from the studies of water phantoms scanned at various tube currents. Other scanning parameters were identical to those used to obtain unenhanced and contrast-enhanced studies of the 100 patients. The SD values were measured from images scanned at an adjusted tube current, and the images of normal coronary and internal mammary arteries were graded. Radiation doses measured using the volume CT dose index (CTDI(vol)) were compared between the SD of the CT attenuation values and the modulation parameters suggested by the manufacturer of the scanner. Image quality was rated as grade 3 (low mottle) on a 4-grade scale by four observers for 92-94 of the 100 patients (average, 92.5%). The mean SD value at an adjusted tube current was 12.1 H with an SD of 0.758 H (target SD = 12 H). A radiation dose reduction of 9-45% was achieved in patients grouped by weight who weighed less than 70 kg, and a reduction of up to 71% was seen in individual cases. Modulating tube current using the SD of CT attenuation values from the left atrium is a highly reliable method of achieving uniform image quality in coronary CTA.</description><subject>Applied radiobiology (equipment, dosimetry...)</subject><subject>Biological and medical sciences</subject><subject>Biological effects of radiation</subject><subject>Cardiology. Vascular system</subject><subject>Cardiovascular system</subject><subject>Coronary Angiography - methods</subject><subject>Coronary Artery Disease - diagnostic imaging</subject><subject>Coronary heart disease</subject><subject>Female</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Heart</subject><subject>Heart Atria - diagnostic imaging</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Radiation Dosage</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Radiographic Image Enhancement - methods</subject><subject>Radiographic Image Interpretation, Computer-Assisted - methods</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Tissues, organs and organisms biophysics</subject><subject>Tomography, X-Ray Computed - methods</subject><issn>0361-803X</issn><issn>1546-3141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpF0E2L2zAQBmBRWrrZbU-9F13ay-J0xnIk-2jcry1bStsEehOyPXJUbDlIdkP-fR0S2MMwMDwMMy9jbxDWaYrZh_LbrzXINaaAz9gKN5lMBGb4nK1ASExyEH9u2G2MfwFA5YV6yW5QbVSBClas33lnxzDwh8F0xH_OpnfTiZfN3tE_anl94tu5Jl7NIZCf-PexnXszudHzXXS-478_8tHycprIz5e587waw-hNOPFqy0vfubEL5rA_vWIvrOkjvb72O7b7_GlbfU0ef3x5qMrHpBFZPiUtSaxBopBAoDbZUmnaUK3y1OZN09osba3NigJJgVQZgRSWWkRaHhZWijt2f9nbhDHGQFYfghuWezSCPmeml8w0SH3ObNFvL_ow1wO1T_Ya0gLeXYGJjeltML5x8cnluYS0EIt7f3F71-2PLpCOg-n7ZS3q4_GIeaHxrMV_FMWA9Q</recordid><startdate>20070701</startdate><enddate>20070701</enddate><creator>Hur, Gham</creator><creator>Hong, Seong Wan</creator><creator>Kim, Su Young</creator><creator>Kim, Yong Hoon</creator><creator>Hwang, Yoon Joon</creator><creator>Lee, Won Ro</creator><creator>Cha, Soon Joo</creator><general>Am Roentgen Ray Soc</general><general>American Roentgen Ray Society</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20070701</creationdate><title>Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography</title><author>Hur, Gham ; Hong, Seong Wan ; Kim, Su Young ; Kim, Yong Hoon ; Hwang, Yoon Joon ; Lee, Won Ro ; Cha, Soon Joo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c348t-de61b061360e075407522ceb782f8ccdf42dff4991e70674e063fed11e0363f63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Applied radiobiology (equipment, dosimetry...)</topic><topic>Biological and medical sciences</topic><topic>Biological effects of radiation</topic><topic>Cardiology. Vascular system</topic><topic>Cardiovascular system</topic><topic>Coronary Angiography - methods</topic><topic>Coronary Artery Disease - diagnostic imaging</topic><topic>Coronary heart disease</topic><topic>Female</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Heart</topic><topic>Heart Atria - diagnostic imaging</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Radiation Dosage</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Radiographic Image Enhancement - methods</topic><topic>Radiographic Image Interpretation, Computer-Assisted - methods</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Tissues, organs and organisms biophysics</topic><topic>Tomography, X-Ray Computed - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hur, Gham</creatorcontrib><creatorcontrib>Hong, Seong Wan</creatorcontrib><creatorcontrib>Kim, Su Young</creatorcontrib><creatorcontrib>Kim, Yong Hoon</creatorcontrib><creatorcontrib>Hwang, Yoon Joon</creatorcontrib><creatorcontrib>Lee, Won Ro</creatorcontrib><creatorcontrib>Cha, Soon Joo</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>American journal of roentgenology (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hur, Gham</au><au>Hong, Seong Wan</au><au>Kim, Su Young</au><au>Kim, Yong Hoon</au><au>Hwang, Yoon Joon</au><au>Lee, Won Ro</au><au>Cha, Soon Joo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography</atitle><jtitle>American journal of roentgenology (1976)</jtitle><addtitle>AJR Am J Roentgenol</addtitle><date>2007-07-01</date><risdate>2007</risdate><volume>189</volume><issue>1</issue><spage>188</spage><epage>196</epage><pages>188-196</pages><issn>0361-803X</issn><eissn>1546-3141</eissn><coden>AAJRDX</coden><abstract>The objective of our study was to evaluate whether the SD of CT attenuation values obtained from unenhanced scans of the left atrium is a reliable parameter for the individual modulation of tube current to achieve uniform image quality in coronary CT angiography (CTA). One hundred patients (59 men and 41 women) who were suspected to have coronary artery disease underwent coronary CTA using a 64-MDCT scanner. In addition to clinical studies, we also performed measurements on water phantoms. Tube current was modulated by the SD of the CT attenuation values measured from the left atrium on unenhanced images scanned at 300 mA. A modulation table was created from data obtained from the studies of water phantoms scanned at various tube currents. Other scanning parameters were identical to those used to obtain unenhanced and contrast-enhanced studies of the 100 patients. The SD values were measured from images scanned at an adjusted tube current, and the images of normal coronary and internal mammary arteries were graded. Radiation doses measured using the volume CT dose index (CTDI(vol)) were compared between the SD of the CT attenuation values and the modulation parameters suggested by the manufacturer of the scanner. Image quality was rated as grade 3 (low mottle) on a 4-grade scale by four observers for 92-94 of the 100 patients (average, 92.5%). The mean SD value at an adjusted tube current was 12.1 H with an SD of 0.758 H (target SD = 12 H). A radiation dose reduction of 9-45% was achieved in patients grouped by weight who weighed less than 70 kg, and a reduction of up to 71% was seen in individual cases. Modulating tube current using the SD of CT attenuation values from the left atrium is a highly reliable method of achieving uniform image quality in coronary CTA.</abstract><cop>Leesburg, VA</cop><pub>Am Roentgen Ray Soc</pub><pmid>17579170</pmid><doi>10.2214/AJR.06.1201</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0361-803X
ispartof American journal of roentgenology (1976), 2007-07, Vol.189 (1), p.188-196
issn 0361-803X
1546-3141
language eng
recordid cdi_crossref_primary_10_2214_AJR_06_1201
source American Roentgen Ray Society; MEDLINE; Alma/SFX Local Collection
subjects Applied radiobiology (equipment, dosimetry...)
Biological and medical sciences
Biological effects of radiation
Cardiology. Vascular system
Cardiovascular system
Coronary Angiography - methods
Coronary Artery Disease - diagnostic imaging
Coronary heart disease
Female
Fundamental and applied biological sciences. Psychology
Heart
Heart Atria - diagnostic imaging
Humans
Investigative techniques, diagnostic techniques (general aspects)
Male
Medical sciences
Middle Aged
Radiation Dosage
Radiodiagnosis. Nmr imagery. Nmr spectrometry
Radiographic Image Enhancement - methods
Radiographic Image Interpretation, Computer-Assisted - methods
Reproducibility of Results
Sensitivity and Specificity
Tissues, organs and organisms biophysics
Tomography, X-Ray Computed - methods
title Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T12%3A37%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Uniform%20Image%20Quality%20Achieved%20by%20Tube%20Current%20Modulation%20Using%20SD%20of%20Attenuation%20in%20Coronary%20CT%20Angiography&rft.jtitle=American%20journal%20of%20roentgenology%20(1976)&rft.au=Hur,%20Gham&rft.date=2007-07-01&rft.volume=189&rft.issue=1&rft.spage=188&rft.epage=196&rft.pages=188-196&rft.issn=0361-803X&rft.eissn=1546-3141&rft.coden=AAJRDX&rft_id=info:doi/10.2214/AJR.06.1201&rft_dat=%3Cpubmed_cross%3E17579170%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/17579170&rfr_iscdi=true