Experience with UASB reactor start-up under different operating conditions

Four laboratory upflow anaerobic sludge blanket (UASB) reactors were operated at different operating parameters viz., hydraulic retention time (HRT), upflow velocity, organic concentration, and Ca2+ concentration in the wastewater. These operating parameters gave different values of organic loading...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water science and technology 1996-09, Vol.34 (5-6), p.421-428
Hauptverfasser: Ghangrekar, M. M., Asolekar, S. R., Ranganathan, K. R., Joshi, S. G.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 428
container_issue 5-6
container_start_page 421
container_title Water science and technology
container_volume 34
creator Ghangrekar, M. M.
Asolekar, S. R.
Ranganathan, K. R.
Joshi, S. G.
description Four laboratory upflow anaerobic sludge blanket (UASB) reactors were operated at different operating parameters viz., hydraulic retention time (HRT), upflow velocity, organic concentration, and Ca2+ concentration in the wastewater. These operating parameters gave different values of organic loading rates (OLRs) and sludge loading rates (SLRs). The reactor performance during start-up was evaluated at different values of the above listed parameters. Also, the effects of these parameters on the granule characteristics were investigated. It was observed that COD removal efficiency at steady state was profoundly influenced by SLR. The reactor started with SLR of 0.6 kgCOD/ kg VSS.d could result in about 50% COD removal at steady state. The reactor performance could not improve even after three months of operation. Up to 0.3 kgCOD/ kgVSS.d the reactor performance was good with more than 90% COD removal at steady state. The OLD and SLR also determine time required for the reactor to achieve steady state. Different operating conditions also have the bearing on the strength of the granules cultivated. The methanogenic activity measured on acetate for each reactor was observed between 0.259 and 0.909 kg CH4 COD/ kgVSS.d. The sludge production in all the reactors was between 0.087 and 0.13 kgVSS/ kgCODin. The mathematical model was developed in order to predict sludge production.
doi_str_mv 10.2166/wst.1996.0578
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_2166_wst_1996_0578</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_2166_wst_1996_0578</sourcerecordid><originalsourceid>FETCH-LOGICAL-c167t-7ee1a1f5c6320c7a76e85fb2b4327146257e15163d5730163909db493ebbef2e3</originalsourceid><addsrcrecordid>eNotkEtPAyEYRYnRxLG6dM8fYOQxQFnWpr7SxIV2TRjmQzHKTICm-u_tRFfnbu5N7kHomtGWM6VuDqW2zBjVUqmXJ6iZMzFa8FPUUK4FYZyLc3RRygelVIuONuhp8z1BjpA84EOs73i3ernFGZyvY8alulzJfsL7NEDGQwwBMqSKx2PJ1ZjesB_TEGscU7lEZ8F9Frj65wLt7jav6weyfb5_XK-2xDOlK9EAzLEgvRKceu20gqUMPe87wTXrFJcamGRKDFILeqShZug7I6DvIXAQC0T-dn0eS8kQ7JTjl8s_llE7i7BHEXY-b2cR4heVsFHI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Experience with UASB reactor start-up under different operating conditions</title><source>Free E-Journal (出版社公開部分のみ)</source><creator>Ghangrekar, M. M. ; Asolekar, S. R. ; Ranganathan, K. R. ; Joshi, S. G.</creator><creatorcontrib>Ghangrekar, M. M. ; Asolekar, S. R. ; Ranganathan, K. R. ; Joshi, S. G.</creatorcontrib><description>Four laboratory upflow anaerobic sludge blanket (UASB) reactors were operated at different operating parameters viz., hydraulic retention time (HRT), upflow velocity, organic concentration, and Ca2+ concentration in the wastewater. These operating parameters gave different values of organic loading rates (OLRs) and sludge loading rates (SLRs). The reactor performance during start-up was evaluated at different values of the above listed parameters. Also, the effects of these parameters on the granule characteristics were investigated. It was observed that COD removal efficiency at steady state was profoundly influenced by SLR. The reactor started with SLR of 0.6 kgCOD/ kg VSS.d could result in about 50% COD removal at steady state. The reactor performance could not improve even after three months of operation. Up to 0.3 kgCOD/ kgVSS.d the reactor performance was good with more than 90% COD removal at steady state. The OLD and SLR also determine time required for the reactor to achieve steady state. Different operating conditions also have the bearing on the strength of the granules cultivated. The methanogenic activity measured on acetate for each reactor was observed between 0.259 and 0.909 kg CH4 COD/ kgVSS.d. The sludge production in all the reactors was between 0.087 and 0.13 kgVSS/ kgCODin. The mathematical model was developed in order to predict sludge production.</description><identifier>ISSN: 0273-1223</identifier><identifier>EISSN: 1996-9732</identifier><identifier>DOI: 10.2166/wst.1996.0578</identifier><language>eng</language><ispartof>Water science and technology, 1996-09, Vol.34 (5-6), p.421-428</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c167t-7ee1a1f5c6320c7a76e85fb2b4327146257e15163d5730163909db493ebbef2e3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Ghangrekar, M. M.</creatorcontrib><creatorcontrib>Asolekar, S. R.</creatorcontrib><creatorcontrib>Ranganathan, K. R.</creatorcontrib><creatorcontrib>Joshi, S. G.</creatorcontrib><title>Experience with UASB reactor start-up under different operating conditions</title><title>Water science and technology</title><description>Four laboratory upflow anaerobic sludge blanket (UASB) reactors were operated at different operating parameters viz., hydraulic retention time (HRT), upflow velocity, organic concentration, and Ca2+ concentration in the wastewater. These operating parameters gave different values of organic loading rates (OLRs) and sludge loading rates (SLRs). The reactor performance during start-up was evaluated at different values of the above listed parameters. Also, the effects of these parameters on the granule characteristics were investigated. It was observed that COD removal efficiency at steady state was profoundly influenced by SLR. The reactor started with SLR of 0.6 kgCOD/ kg VSS.d could result in about 50% COD removal at steady state. The reactor performance could not improve even after three months of operation. Up to 0.3 kgCOD/ kgVSS.d the reactor performance was good with more than 90% COD removal at steady state. The OLD and SLR also determine time required for the reactor to achieve steady state. Different operating conditions also have the bearing on the strength of the granules cultivated. The methanogenic activity measured on acetate for each reactor was observed between 0.259 and 0.909 kg CH4 COD/ kgVSS.d. The sludge production in all the reactors was between 0.087 and 0.13 kgVSS/ kgCODin. The mathematical model was developed in order to predict sludge production.</description><issn>0273-1223</issn><issn>1996-9732</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNotkEtPAyEYRYnRxLG6dM8fYOQxQFnWpr7SxIV2TRjmQzHKTICm-u_tRFfnbu5N7kHomtGWM6VuDqW2zBjVUqmXJ6iZMzFa8FPUUK4FYZyLc3RRygelVIuONuhp8z1BjpA84EOs73i3ernFGZyvY8alulzJfsL7NEDGQwwBMqSKx2PJ1ZjesB_TEGscU7lEZ8F9Frj65wLt7jav6weyfb5_XK-2xDOlK9EAzLEgvRKceu20gqUMPe87wTXrFJcamGRKDFILeqShZug7I6DvIXAQC0T-dn0eS8kQ7JTjl8s_llE7i7BHEXY-b2cR4heVsFHI</recordid><startdate>19960901</startdate><enddate>19960901</enddate><creator>Ghangrekar, M. M.</creator><creator>Asolekar, S. R.</creator><creator>Ranganathan, K. R.</creator><creator>Joshi, S. G.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19960901</creationdate><title>Experience with UASB reactor start-up under different operating conditions</title><author>Ghangrekar, M. M. ; Asolekar, S. R. ; Ranganathan, K. R. ; Joshi, S. G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c167t-7ee1a1f5c6320c7a76e85fb2b4327146257e15163d5730163909db493ebbef2e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ghangrekar, M. M.</creatorcontrib><creatorcontrib>Asolekar, S. R.</creatorcontrib><creatorcontrib>Ranganathan, K. R.</creatorcontrib><creatorcontrib>Joshi, S. G.</creatorcontrib><collection>CrossRef</collection><jtitle>Water science and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ghangrekar, M. M.</au><au>Asolekar, S. R.</au><au>Ranganathan, K. R.</au><au>Joshi, S. G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experience with UASB reactor start-up under different operating conditions</atitle><jtitle>Water science and technology</jtitle><date>1996-09-01</date><risdate>1996</risdate><volume>34</volume><issue>5-6</issue><spage>421</spage><epage>428</epage><pages>421-428</pages><issn>0273-1223</issn><eissn>1996-9732</eissn><abstract>Four laboratory upflow anaerobic sludge blanket (UASB) reactors were operated at different operating parameters viz., hydraulic retention time (HRT), upflow velocity, organic concentration, and Ca2+ concentration in the wastewater. These operating parameters gave different values of organic loading rates (OLRs) and sludge loading rates (SLRs). The reactor performance during start-up was evaluated at different values of the above listed parameters. Also, the effects of these parameters on the granule characteristics were investigated. It was observed that COD removal efficiency at steady state was profoundly influenced by SLR. The reactor started with SLR of 0.6 kgCOD/ kg VSS.d could result in about 50% COD removal at steady state. The reactor performance could not improve even after three months of operation. Up to 0.3 kgCOD/ kgVSS.d the reactor performance was good with more than 90% COD removal at steady state. The OLD and SLR also determine time required for the reactor to achieve steady state. Different operating conditions also have the bearing on the strength of the granules cultivated. The methanogenic activity measured on acetate for each reactor was observed between 0.259 and 0.909 kg CH4 COD/ kgVSS.d. The sludge production in all the reactors was between 0.087 and 0.13 kgVSS/ kgCODin. The mathematical model was developed in order to predict sludge production.</abstract><doi>10.2166/wst.1996.0578</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0273-1223
ispartof Water science and technology, 1996-09, Vol.34 (5-6), p.421-428
issn 0273-1223
1996-9732
language eng
recordid cdi_crossref_primary_10_2166_wst_1996_0578
source Free E-Journal (出版社公開部分のみ)
title Experience with UASB reactor start-up under different operating conditions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T13%3A39%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experience%20with%20UASB%20reactor%20start-up%20under%20different%20operating%20conditions&rft.jtitle=Water%20science%20and%20technology&rft.au=Ghangrekar,%20M.%20M.&rft.date=1996-09-01&rft.volume=34&rft.issue=5-6&rft.spage=421&rft.epage=428&rft.pages=421-428&rft.issn=0273-1223&rft.eissn=1996-9732&rft_id=info:doi/10.2166/wst.1996.0578&rft_dat=%3Ccrossref%3E10_2166_wst_1996_0578%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true