A Selective Flow-Rate Independent Flow Injection Analysis Technique: Combination of a Single Bead String Reactor with Rapid Scan Square-Wave Voltammetry

The response of a flow injection analysis with an electrochemical detector was made independent of the flow rate by using a singe bead string reactor tube (SBSR) and by operating the detector in the rapid-scan square-wave voltammetric mode. The SBSR reduced the flow-rate dependence of the maximum co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical Sciences 1989/10/10, Vol.5(5), pp.567-570
Hauptverfasser: YOSHIZAWA, Daisuke, SHIMIZU, Kunio, SATO, Gen P., KUMAKURA, Konosuke, AOKI, Koichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 570
container_issue 5
container_start_page 567
container_title Analytical Sciences
container_volume 5
creator YOSHIZAWA, Daisuke
SHIMIZU, Kunio
SATO, Gen P.
KUMAKURA, Konosuke
AOKI, Koichi
description The response of a flow injection analysis with an electrochemical detector was made independent of the flow rate by using a singe bead string reactor tube (SBSR) and by operating the detector in the rapid-scan square-wave voltammetric mode. The SBSR reduced the flow-rate dependence of the maximum concentrations of the sample zone to 10% and the square-wave voltammetric peak height was virtually independent of the flow rate. The voltage scan was triggered at the point of the maximum concentration of the sample zone. The point was detected by monitoring the ECD current at a constant potential. The operation was controlled by a personal computer. The detection limits for [Fe(CN)6]4- and dopamine were ca. 0.6nmol (=2×10-5mol dm-3×29mm3). The use of square-wave voltammetry allowed for the simultaneous determination of more than one component.
doi_str_mv 10.2116/analsci.5.567
format Article
fullrecord <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_2116_analsci_5_567</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_analsci1985_5_5_5_5_567_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c433t-43ce08a86c35cb50e5b6c3213b3a01cd06206d63248848816f146a2dd5a4a623</originalsourceid><addsrcrecordid>eNo9kEtPAjEUhRujiYgu3XfhdrCPmTK6QyJKQmICRJeTS-eOlAwdaIuEf-LPtTwkbfq45-tpewi556wjOFePYKH22nSyTqa6F6TFZZonQqTqkrTYE2eJkim7JjfeLxjjIheiRX57dII16mB-kA7qZpuMISAd2hJXGAcbDtVYWOyhxtJevGXnjadT1HNr1ht8pv1mOTMWDnpTUaATY79rpC8IJZ0EF3d0jKBD4-jWhDkdw8pERYOlk_UGHCZfEB_w2dQBlksMbndLrqr4Hbw7zW0yHbxO--_J6ONt2O-NEp1KGZJUamQ55ErLTM8yhtksLgWXMwmM65IpwVSppEjzPHauKp4qEGWZQQpKyDZJjrbaNd47rIqVM0twu4KzYp9qcUq1yIqYauQfjvwKvIa6cmC18edDSkVPISP2esQWPsA3nnVwwega_035U54V56a6Z13PwRVo5R8VCZON</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Selective Flow-Rate Independent Flow Injection Analysis Technique: Combination of a Single Bead String Reactor with Rapid Scan Square-Wave Voltammetry</title><source>J-STAGE Free</source><source>Freely Accessible Japanese Titles</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Free Full-Text Journals in Chemistry</source><creator>YOSHIZAWA, Daisuke ; SHIMIZU, Kunio ; SATO, Gen P. ; KUMAKURA, Konosuke ; AOKI, Koichi</creator><creatorcontrib>YOSHIZAWA, Daisuke ; SHIMIZU, Kunio ; SATO, Gen P. ; KUMAKURA, Konosuke ; AOKI, Koichi</creatorcontrib><description>The response of a flow injection analysis with an electrochemical detector was made independent of the flow rate by using a singe bead string reactor tube (SBSR) and by operating the detector in the rapid-scan square-wave voltammetric mode. The SBSR reduced the flow-rate dependence of the maximum concentrations of the sample zone to 10% and the square-wave voltammetric peak height was virtually independent of the flow rate. The voltage scan was triggered at the point of the maximum concentration of the sample zone. The point was detected by monitoring the ECD current at a constant potential. The operation was controlled by a personal computer. The detection limits for [Fe(CN)6]4- and dopamine were ca. 0.6nmol (=2×10-5mol dm-3×29mm3). The use of square-wave voltammetry allowed for the simultaneous determination of more than one component.</description><identifier>ISSN: 0910-6340</identifier><identifier>EISSN: 1348-2246</identifier><identifier>DOI: 10.2116/analsci.5.567</identifier><identifier>CODEN: ANSCEN</identifier><language>eng</language><publisher>Tokyo: The Japan Society for Analytical Chemistry</publisher><subject>Analytical chemistry ; Chemistry ; Electrochemical methods ; Exact sciences and technology ; Flow injection analysis ; square-wave voltammetry</subject><ispartof>Analytical Sciences, 1989/10/10, Vol.5(5), pp.567-570</ispartof><rights>The Japan Society for Analytical Chemistry</rights><rights>1990 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c433t-43ce08a86c35cb50e5b6c3213b3a01cd06206d63248848816f146a2dd5a4a623</citedby><cites>FETCH-LOGICAL-c433t-43ce08a86c35cb50e5b6c3213b3a01cd06206d63248848816f146a2dd5a4a623</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=6662323$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>YOSHIZAWA, Daisuke</creatorcontrib><creatorcontrib>SHIMIZU, Kunio</creatorcontrib><creatorcontrib>SATO, Gen P.</creatorcontrib><creatorcontrib>KUMAKURA, Konosuke</creatorcontrib><creatorcontrib>AOKI, Koichi</creatorcontrib><title>A Selective Flow-Rate Independent Flow Injection Analysis Technique: Combination of a Single Bead String Reactor with Rapid Scan Square-Wave Voltammetry</title><title>Analytical Sciences</title><description>The response of a flow injection analysis with an electrochemical detector was made independent of the flow rate by using a singe bead string reactor tube (SBSR) and by operating the detector in the rapid-scan square-wave voltammetric mode. The SBSR reduced the flow-rate dependence of the maximum concentrations of the sample zone to 10% and the square-wave voltammetric peak height was virtually independent of the flow rate. The voltage scan was triggered at the point of the maximum concentration of the sample zone. The point was detected by monitoring the ECD current at a constant potential. The operation was controlled by a personal computer. The detection limits for [Fe(CN)6]4- and dopamine were ca. 0.6nmol (=2×10-5mol dm-3×29mm3). The use of square-wave voltammetry allowed for the simultaneous determination of more than one component.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Electrochemical methods</subject><subject>Exact sciences and technology</subject><subject>Flow injection analysis</subject><subject>square-wave voltammetry</subject><issn>0910-6340</issn><issn>1348-2246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><recordid>eNo9kEtPAjEUhRujiYgu3XfhdrCPmTK6QyJKQmICRJeTS-eOlAwdaIuEf-LPtTwkbfq45-tpewi556wjOFePYKH22nSyTqa6F6TFZZonQqTqkrTYE2eJkim7JjfeLxjjIheiRX57dII16mB-kA7qZpuMISAd2hJXGAcbDtVYWOyhxtJevGXnjadT1HNr1ht8pv1mOTMWDnpTUaATY79rpC8IJZ0EF3d0jKBD4-jWhDkdw8pERYOlk_UGHCZfEB_w2dQBlksMbndLrqr4Hbw7zW0yHbxO--_J6ONt2O-NEp1KGZJUamQ55ErLTM8yhtksLgWXMwmM65IpwVSppEjzPHauKp4qEGWZQQpKyDZJjrbaNd47rIqVM0twu4KzYp9qcUq1yIqYauQfjvwKvIa6cmC18edDSkVPISP2esQWPsA3nnVwwega_035U54V56a6Z13PwRVo5R8VCZON</recordid><startdate>19891001</startdate><enddate>19891001</enddate><creator>YOSHIZAWA, Daisuke</creator><creator>SHIMIZU, Kunio</creator><creator>SATO, Gen P.</creator><creator>KUMAKURA, Konosuke</creator><creator>AOKI, Koichi</creator><general>The Japan Society for Analytical Chemistry</general><general>Japan Society for Analytical Chemistry</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19891001</creationdate><title>A Selective Flow-Rate Independent Flow Injection Analysis Technique: Combination of a Single Bead String Reactor with Rapid Scan Square-Wave Voltammetry</title><author>YOSHIZAWA, Daisuke ; SHIMIZU, Kunio ; SATO, Gen P. ; KUMAKURA, Konosuke ; AOKI, Koichi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c433t-43ce08a86c35cb50e5b6c3213b3a01cd06206d63248848816f146a2dd5a4a623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Electrochemical methods</topic><topic>Exact sciences and technology</topic><topic>Flow injection analysis</topic><topic>square-wave voltammetry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>YOSHIZAWA, Daisuke</creatorcontrib><creatorcontrib>SHIMIZU, Kunio</creatorcontrib><creatorcontrib>SATO, Gen P.</creatorcontrib><creatorcontrib>KUMAKURA, Konosuke</creatorcontrib><creatorcontrib>AOKI, Koichi</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Analytical Sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>YOSHIZAWA, Daisuke</au><au>SHIMIZU, Kunio</au><au>SATO, Gen P.</au><au>KUMAKURA, Konosuke</au><au>AOKI, Koichi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Selective Flow-Rate Independent Flow Injection Analysis Technique: Combination of a Single Bead String Reactor with Rapid Scan Square-Wave Voltammetry</atitle><jtitle>Analytical Sciences</jtitle><date>1989-10-01</date><risdate>1989</risdate><volume>5</volume><issue>5</issue><spage>567</spage><epage>570</epage><pages>567-570</pages><issn>0910-6340</issn><eissn>1348-2246</eissn><coden>ANSCEN</coden><abstract>The response of a flow injection analysis with an electrochemical detector was made independent of the flow rate by using a singe bead string reactor tube (SBSR) and by operating the detector in the rapid-scan square-wave voltammetric mode. The SBSR reduced the flow-rate dependence of the maximum concentrations of the sample zone to 10% and the square-wave voltammetric peak height was virtually independent of the flow rate. The voltage scan was triggered at the point of the maximum concentration of the sample zone. The point was detected by monitoring the ECD current at a constant potential. The operation was controlled by a personal computer. The detection limits for [Fe(CN)6]4- and dopamine were ca. 0.6nmol (=2×10-5mol dm-3×29mm3). The use of square-wave voltammetry allowed for the simultaneous determination of more than one component.</abstract><cop>Tokyo</cop><pub>The Japan Society for Analytical Chemistry</pub><doi>10.2116/analsci.5.567</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0910-6340
ispartof Analytical Sciences, 1989/10/10, Vol.5(5), pp.567-570
issn 0910-6340
1348-2246
language eng
recordid cdi_crossref_primary_10_2116_analsci_5_567
source J-STAGE Free; Freely Accessible Japanese Titles; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Free Full-Text Journals in Chemistry
subjects Analytical chemistry
Chemistry
Electrochemical methods
Exact sciences and technology
Flow injection analysis
square-wave voltammetry
title A Selective Flow-Rate Independent Flow Injection Analysis Technique: Combination of a Single Bead String Reactor with Rapid Scan Square-Wave Voltammetry
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T09%3A08%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Selective%20Flow-Rate%20Independent%20Flow%20Injection%20Analysis%20Technique:%20Combination%20of%20a%20Single%20Bead%20String%20Reactor%20with%20Rapid%20Scan%20Square-Wave%20Voltammetry&rft.jtitle=Analytical%20Sciences&rft.au=YOSHIZAWA,%20Daisuke&rft.date=1989-10-01&rft.volume=5&rft.issue=5&rft.spage=567&rft.epage=570&rft.pages=567-570&rft.issn=0910-6340&rft.eissn=1348-2246&rft.coden=ANSCEN&rft_id=info:doi/10.2116/analsci.5.567&rft_dat=%3Cjstage_cross%3Earticle_analsci1985_5_5_5_5_567_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true