Designing an Electrochemical System for Efficient Removal of Chromium from Leachate by Electrocoagulation Using a Solar Panel as the Power Supply
Here, we report the removal of chromium from landfill leachate by electrocoagulation (EC) using iron and aluminum electrodes and a solar panel as the electrical energy source. Two rectangular plates of aluminum and iron were used as cathode and anode, respectively. Different kinds of operational par...
Gespeichert in:
Veröffentlicht in: | International journal of electrochemical science 2019-07, Vol.14 (7), p.6337-6346 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 6346 |
---|---|
container_issue | 7 |
container_start_page | 6337 |
container_title | International journal of electrochemical science |
container_volume | 14 |
creator | Zaroun, Mostafa Mohammadi Yari, Abdollah |
description | Here, we report the removal of chromium from landfill leachate by electrocoagulation (EC) using iron and aluminum electrodes and a solar panel as the electrical energy source. Two rectangular plates of aluminum and iron were used as cathode and anode, respectively. Different kinds of operational parameters such as contact time, pH, inter-electrode distance and current density were investigated and optimized to obtain the best process function. Based on the findings, the removal efficiency of chromium increased by increasing the current density and the reaction time and decreasing the distance between the electrodes. The experimental results indicated that the removal efficiency of chromium of 98.0% from raw leachate was obtained under the optimized conditions of current density 4.5 A/m2, initial pH of 3, contact times 27.0 min and the electrode-distance of 0.5 cm. |
doi_str_mv | 10.20964/2019.07.57 |
format | Article |
fullrecord | <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_20964_2019_07_57</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1452398123123765</els_id><sourcerecordid>S1452398123123765</sourcerecordid><originalsourceid>FETCH-LOGICAL-c316t-202acee7085a9601e89b256f52213a1d5afdbd9629b0e2cf13452c455292939a3</originalsourceid><addsrcrecordid>eNptkF1LwzAUhoMoOHRX_oHcS2eSNu1yKXN-wMDh3HVI05M10jYj6Sb9Gf5js03EC8_Ne-C85-tB6IaSCSMiz-4YoWJCigkvztCIZpwlqZjS8z_5JRqH8EFiZCLNimKEvh4g2E1nuw1WHZ43oHvvdA2t1arBqyH00GLjPJ4bY7WFrsdv0Lp9LDqDZ7V3rd1FR1S8AKVr1QMuh99JTm12jeqt6_A6HLfglWuUx0vVQYNVwH0NeOk-wePVbrtthmt0YVQTYPyjV2j9OH-fPSeL16eX2f0i0SnN-4QRpjRAQaZciZxQmIqS8dxwxmiqaMWVqcpK5EyUBJg2NI0QdMY5E0ykQqVX6PY0V3sXggcjt962yg-SEnkEKg9AJSkkL6Kbn9wQT9pb8DIcaGiorI-fysrZf_u-AfO4eyA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Designing an Electrochemical System for Efficient Removal of Chromium from Leachate by Electrocoagulation Using a Solar Panel as the Power Supply</title><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Zaroun, Mostafa Mohammadi ; Yari, Abdollah</creator><creatorcontrib>Zaroun, Mostafa Mohammadi ; Yari, Abdollah</creatorcontrib><description>Here, we report the removal of chromium from landfill leachate by electrocoagulation (EC) using iron and aluminum electrodes and a solar panel as the electrical energy source. Two rectangular plates of aluminum and iron were used as cathode and anode, respectively. Different kinds of operational parameters such as contact time, pH, inter-electrode distance and current density were investigated and optimized to obtain the best process function. Based on the findings, the removal efficiency of chromium increased by increasing the current density and the reaction time and decreasing the distance between the electrodes. The experimental results indicated that the removal efficiency of chromium of 98.0% from raw leachate was obtained under the optimized conditions of current density 4.5 A/m2, initial pH of 3, contact times 27.0 min and the electrode-distance of 0.5 cm.</description><identifier>ISSN: 1452-3981</identifier><identifier>EISSN: 1452-3981</identifier><identifier>DOI: 10.20964/2019.07.57</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>chromium ; electrochemical system ; electrocoagulation ; iron and aluminum electrodes ; raw leachate</subject><ispartof>International journal of electrochemical science, 2019-07, Vol.14 (7), p.6337-6346</ispartof><rights>2019 The Authors. Published by ESG</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c316t-202acee7085a9601e89b256f52213a1d5afdbd9629b0e2cf13452c455292939a3</citedby><cites>FETCH-LOGICAL-c316t-202acee7085a9601e89b256f52213a1d5afdbd9629b0e2cf13452c455292939a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Zaroun, Mostafa Mohammadi</creatorcontrib><creatorcontrib>Yari, Abdollah</creatorcontrib><title>Designing an Electrochemical System for Efficient Removal of Chromium from Leachate by Electrocoagulation Using a Solar Panel as the Power Supply</title><title>International journal of electrochemical science</title><description>Here, we report the removal of chromium from landfill leachate by electrocoagulation (EC) using iron and aluminum electrodes and a solar panel as the electrical energy source. Two rectangular plates of aluminum and iron were used as cathode and anode, respectively. Different kinds of operational parameters such as contact time, pH, inter-electrode distance and current density were investigated and optimized to obtain the best process function. Based on the findings, the removal efficiency of chromium increased by increasing the current density and the reaction time and decreasing the distance between the electrodes. The experimental results indicated that the removal efficiency of chromium of 98.0% from raw leachate was obtained under the optimized conditions of current density 4.5 A/m2, initial pH of 3, contact times 27.0 min and the electrode-distance of 0.5 cm.</description><subject>chromium</subject><subject>electrochemical system</subject><subject>electrocoagulation</subject><subject>iron and aluminum electrodes</subject><subject>raw leachate</subject><issn>1452-3981</issn><issn>1452-3981</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNptkF1LwzAUhoMoOHRX_oHcS2eSNu1yKXN-wMDh3HVI05M10jYj6Sb9Gf5js03EC8_Ne-C85-tB6IaSCSMiz-4YoWJCigkvztCIZpwlqZjS8z_5JRqH8EFiZCLNimKEvh4g2E1nuw1WHZ43oHvvdA2t1arBqyH00GLjPJ4bY7WFrsdv0Lp9LDqDZ7V3rd1FR1S8AKVr1QMuh99JTm12jeqt6_A6HLfglWuUx0vVQYNVwH0NeOk-wePVbrtthmt0YVQTYPyjV2j9OH-fPSeL16eX2f0i0SnN-4QRpjRAQaZciZxQmIqS8dxwxmiqaMWVqcpK5EyUBJg2NI0QdMY5E0ykQqVX6PY0V3sXggcjt962yg-SEnkEKg9AJSkkL6Kbn9wQT9pb8DIcaGiorI-fysrZf_u-AfO4eyA</recordid><startdate>20190701</startdate><enddate>20190701</enddate><creator>Zaroun, Mostafa Mohammadi</creator><creator>Yari, Abdollah</creator><general>Elsevier B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20190701</creationdate><title>Designing an Electrochemical System for Efficient Removal of Chromium from Leachate by Electrocoagulation Using a Solar Panel as the Power Supply</title><author>Zaroun, Mostafa Mohammadi ; Yari, Abdollah</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c316t-202acee7085a9601e89b256f52213a1d5afdbd9629b0e2cf13452c455292939a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>chromium</topic><topic>electrochemical system</topic><topic>electrocoagulation</topic><topic>iron and aluminum electrodes</topic><topic>raw leachate</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zaroun, Mostafa Mohammadi</creatorcontrib><creatorcontrib>Yari, Abdollah</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><jtitle>International journal of electrochemical science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zaroun, Mostafa Mohammadi</au><au>Yari, Abdollah</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Designing an Electrochemical System for Efficient Removal of Chromium from Leachate by Electrocoagulation Using a Solar Panel as the Power Supply</atitle><jtitle>International journal of electrochemical science</jtitle><date>2019-07-01</date><risdate>2019</risdate><volume>14</volume><issue>7</issue><spage>6337</spage><epage>6346</epage><pages>6337-6346</pages><issn>1452-3981</issn><eissn>1452-3981</eissn><abstract>Here, we report the removal of chromium from landfill leachate by electrocoagulation (EC) using iron and aluminum electrodes and a solar panel as the electrical energy source. Two rectangular plates of aluminum and iron were used as cathode and anode, respectively. Different kinds of operational parameters such as contact time, pH, inter-electrode distance and current density were investigated and optimized to obtain the best process function. Based on the findings, the removal efficiency of chromium increased by increasing the current density and the reaction time and decreasing the distance between the electrodes. The experimental results indicated that the removal efficiency of chromium of 98.0% from raw leachate was obtained under the optimized conditions of current density 4.5 A/m2, initial pH of 3, contact times 27.0 min and the electrode-distance of 0.5 cm.</abstract><pub>Elsevier B.V</pub><doi>10.20964/2019.07.57</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1452-3981 |
ispartof | International journal of electrochemical science, 2019-07, Vol.14 (7), p.6337-6346 |
issn | 1452-3981 1452-3981 |
language | eng |
recordid | cdi_crossref_primary_10_20964_2019_07_57 |
source | EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry |
subjects | chromium electrochemical system electrocoagulation iron and aluminum electrodes raw leachate |
title | Designing an Electrochemical System for Efficient Removal of Chromium from Leachate by Electrocoagulation Using a Solar Panel as the Power Supply |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T18%3A54%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Designing%20an%20Electrochemical%20System%20for%20Efficient%20Removal%20of%20Chromium%20from%20Leachate%20by%20Electrocoagulation%20Using%20a%20Solar%20Panel%20as%20the%20Power%20Supply&rft.jtitle=International%20journal%20of%20electrochemical%20science&rft.au=Zaroun,%20Mostafa%20Mohammadi&rft.date=2019-07-01&rft.volume=14&rft.issue=7&rft.spage=6337&rft.epage=6346&rft.pages=6337-6346&rft.issn=1452-3981&rft.eissn=1452-3981&rft_id=info:doi/10.20964/2019.07.57&rft_dat=%3Celsevier_cross%3ES1452398123123765%3C/elsevier_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S1452398123123765&rfr_iscdi=true |