Comparison of Electrochemical Determination of Purines and Pyrimidines by means of Carbon, Graphite and Gold Paste Electrodes
Comparison of electrochemical detection with the use of thick-film sensors with working electrodes made of graphite, carbon and gold pastes for individual determination of four nucleobases – adenine, guanine, cytosine and thymine is presented. The best results and oxidation peaks for the four nucleo...
Gespeichert in:
Veröffentlicht in: | International journal of electrochemical science 2017-03, Vol.12 (3), p.2329-2343 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2343 |
---|---|
container_issue | 3 |
container_start_page | 2329 |
container_title | International journal of electrochemical science |
container_volume | 12 |
creator | Jankowska-Śliwińska, Joanna Dawgul, Marek Kruk, Jerzy Pijanowska, Dorota G. |
description | Comparison of electrochemical detection with the use of thick-film sensors with working electrodes made of graphite, carbon and gold pastes for individual determination of four nucleobases – adenine, guanine, cytosine and thymine is presented. The best results and oxidation peaks for the four nucleobases were obtained for gold paste electrodes. For purines limits of detection (LOD) and sensitivities obtained with the use of the developed gold paste electrodes were as follows: for adenine – 7.4·10-7 M with mean sensitivity of 26 nA/μM, for guanine for two oxidation peaks – 1.3·10-6 M and 2.6·10-6 M with mean sensitivities 3 nA/μM and 1.6 nA/μM, respectively. Whereas, for pyrimidines, LOD and sensitivities obtained with the use of the same type of electrodes were as follows: for cytosine – 6.3·10-7 M with sensitivity of 39.8 nA/μM, for thymine for two oxidation peaks – 1.3·10-6 M and 6.4·10-7 M with mean sensitivities 11.5 nA/μM and 34.1 nA/μM, respectively. Therefore, the highest sensitivities were obtained for adenine and cytosine, while the lowest values of LOD were for cytosine and thymine determination. |
doi_str_mv | 10.20964/2017.03.16 |
format | Article |
fullrecord | <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_20964_2017_03_16</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1452398123056110</els_id><sourcerecordid>S1452398123056110</sourcerecordid><originalsourceid>FETCH-LOGICAL-c316t-930d553e68771c4b74105806c448f476a4029fc551c33fcbf7cae63a18f334e63</originalsourceid><addsrcrecordid>eNptkD9PwzAQxS0EElXpxBfwDil2bMfJiEIJSJXoALPlOGfVKIkrOyB14Lvj_hkYuOXeSb9393QI3VKyzElV8IecULkkbEmLCzSjXOQZq0p6-Udfo0WMnyQVrxiXcoZ-aj_sdHDRj9hbvOrBTMGbLQzO6B4_wQRhcKOe3AnYfAU3QsR67PBmH9zguuPc7vEAeowHptah9eM9boLebd0ER7jxfXLomMbzkQ7iDbqyuo-wOPc5-nhevdcv2fqtea0f15lhtJiyipFOCAZFKSU1vJWcElGSwnBeWi4LzUleWSMENYxZ01ppNBRM09IyxpOao7vTXhN8jAGs2qXoOuwVJer4PHV4niJM0QMtTjSkSN8OgorGwWigcyElV513__p-AQg2c4U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Comparison of Electrochemical Determination of Purines and Pyrimidines by means of Carbon, Graphite and Gold Paste Electrodes</title><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Jankowska-Śliwińska, Joanna ; Dawgul, Marek ; Kruk, Jerzy ; Pijanowska, Dorota G.</creator><creatorcontrib>Jankowska-Śliwińska, Joanna ; Dawgul, Marek ; Kruk, Jerzy ; Pijanowska, Dorota G.</creatorcontrib><description>Comparison of electrochemical detection with the use of thick-film sensors with working electrodes made of graphite, carbon and gold pastes for individual determination of four nucleobases – adenine, guanine, cytosine and thymine is presented. The best results and oxidation peaks for the four nucleobases were obtained for gold paste electrodes. For purines limits of detection (LOD) and sensitivities obtained with the use of the developed gold paste electrodes were as follows: for adenine – 7.4·10-7 M with mean sensitivity of 26 nA/μM, for guanine for two oxidation peaks – 1.3·10-6 M and 2.6·10-6 M with mean sensitivities 3 nA/μM and 1.6 nA/μM, respectively. Whereas, for pyrimidines, LOD and sensitivities obtained with the use of the same type of electrodes were as follows: for cytosine – 6.3·10-7 M with sensitivity of 39.8 nA/μM, for thymine for two oxidation peaks – 1.3·10-6 M and 6.4·10-7 M with mean sensitivities 11.5 nA/μM and 34.1 nA/μM, respectively. Therefore, the highest sensitivities were obtained for adenine and cytosine, while the lowest values of LOD were for cytosine and thymine determination.</description><identifier>ISSN: 1452-3981</identifier><identifier>EISSN: 1452-3981</identifier><identifier>DOI: 10.20964/2017.03.16</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>differential pulse voltammetry (DPV) ; electrochemical detection ; nucleobases determination ; thick-film electrodes</subject><ispartof>International journal of electrochemical science, 2017-03, Vol.12 (3), p.2329-2343</ispartof><rights>2017 The Authors. Published by ESG</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c316t-930d553e68771c4b74105806c448f476a4029fc551c33fcbf7cae63a18f334e63</citedby><cites>FETCH-LOGICAL-c316t-930d553e68771c4b74105806c448f476a4029fc551c33fcbf7cae63a18f334e63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Jankowska-Śliwińska, Joanna</creatorcontrib><creatorcontrib>Dawgul, Marek</creatorcontrib><creatorcontrib>Kruk, Jerzy</creatorcontrib><creatorcontrib>Pijanowska, Dorota G.</creatorcontrib><title>Comparison of Electrochemical Determination of Purines and Pyrimidines by means of Carbon, Graphite and Gold Paste Electrodes</title><title>International journal of electrochemical science</title><description>Comparison of electrochemical detection with the use of thick-film sensors with working electrodes made of graphite, carbon and gold pastes for individual determination of four nucleobases – adenine, guanine, cytosine and thymine is presented. The best results and oxidation peaks for the four nucleobases were obtained for gold paste electrodes. For purines limits of detection (LOD) and sensitivities obtained with the use of the developed gold paste electrodes were as follows: for adenine – 7.4·10-7 M with mean sensitivity of 26 nA/μM, for guanine for two oxidation peaks – 1.3·10-6 M and 2.6·10-6 M with mean sensitivities 3 nA/μM and 1.6 nA/μM, respectively. Whereas, for pyrimidines, LOD and sensitivities obtained with the use of the same type of electrodes were as follows: for cytosine – 6.3·10-7 M with sensitivity of 39.8 nA/μM, for thymine for two oxidation peaks – 1.3·10-6 M and 6.4·10-7 M with mean sensitivities 11.5 nA/μM and 34.1 nA/μM, respectively. Therefore, the highest sensitivities were obtained for adenine and cytosine, while the lowest values of LOD were for cytosine and thymine determination.</description><subject>differential pulse voltammetry (DPV)</subject><subject>electrochemical detection</subject><subject>nucleobases determination</subject><subject>thick-film electrodes</subject><issn>1452-3981</issn><issn>1452-3981</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNptkD9PwzAQxS0EElXpxBfwDil2bMfJiEIJSJXoALPlOGfVKIkrOyB14Lvj_hkYuOXeSb9393QI3VKyzElV8IecULkkbEmLCzSjXOQZq0p6-Udfo0WMnyQVrxiXcoZ-aj_sdHDRj9hbvOrBTMGbLQzO6B4_wQRhcKOe3AnYfAU3QsR67PBmH9zguuPc7vEAeowHptah9eM9boLebd0ER7jxfXLomMbzkQ7iDbqyuo-wOPc5-nhevdcv2fqtea0f15lhtJiyipFOCAZFKSU1vJWcElGSwnBeWi4LzUleWSMENYxZ01ppNBRM09IyxpOao7vTXhN8jAGs2qXoOuwVJer4PHV4niJM0QMtTjSkSN8OgorGwWigcyElV513__p-AQg2c4U</recordid><startdate>201703</startdate><enddate>201703</enddate><creator>Jankowska-Śliwińska, Joanna</creator><creator>Dawgul, Marek</creator><creator>Kruk, Jerzy</creator><creator>Pijanowska, Dorota G.</creator><general>Elsevier B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201703</creationdate><title>Comparison of Electrochemical Determination of Purines and Pyrimidines by means of Carbon, Graphite and Gold Paste Electrodes</title><author>Jankowska-Śliwińska, Joanna ; Dawgul, Marek ; Kruk, Jerzy ; Pijanowska, Dorota G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c316t-930d553e68771c4b74105806c448f476a4029fc551c33fcbf7cae63a18f334e63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>differential pulse voltammetry (DPV)</topic><topic>electrochemical detection</topic><topic>nucleobases determination</topic><topic>thick-film electrodes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jankowska-Śliwińska, Joanna</creatorcontrib><creatorcontrib>Dawgul, Marek</creatorcontrib><creatorcontrib>Kruk, Jerzy</creatorcontrib><creatorcontrib>Pijanowska, Dorota G.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><jtitle>International journal of electrochemical science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jankowska-Śliwińska, Joanna</au><au>Dawgul, Marek</au><au>Kruk, Jerzy</au><au>Pijanowska, Dorota G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Electrochemical Determination of Purines and Pyrimidines by means of Carbon, Graphite and Gold Paste Electrodes</atitle><jtitle>International journal of electrochemical science</jtitle><date>2017-03</date><risdate>2017</risdate><volume>12</volume><issue>3</issue><spage>2329</spage><epage>2343</epage><pages>2329-2343</pages><issn>1452-3981</issn><eissn>1452-3981</eissn><abstract>Comparison of electrochemical detection with the use of thick-film sensors with working electrodes made of graphite, carbon and gold pastes for individual determination of four nucleobases – adenine, guanine, cytosine and thymine is presented. The best results and oxidation peaks for the four nucleobases were obtained for gold paste electrodes. For purines limits of detection (LOD) and sensitivities obtained with the use of the developed gold paste electrodes were as follows: for adenine – 7.4·10-7 M with mean sensitivity of 26 nA/μM, for guanine for two oxidation peaks – 1.3·10-6 M and 2.6·10-6 M with mean sensitivities 3 nA/μM and 1.6 nA/μM, respectively. Whereas, for pyrimidines, LOD and sensitivities obtained with the use of the same type of electrodes were as follows: for cytosine – 6.3·10-7 M with sensitivity of 39.8 nA/μM, for thymine for two oxidation peaks – 1.3·10-6 M and 6.4·10-7 M with mean sensitivities 11.5 nA/μM and 34.1 nA/μM, respectively. Therefore, the highest sensitivities were obtained for adenine and cytosine, while the lowest values of LOD were for cytosine and thymine determination.</abstract><pub>Elsevier B.V</pub><doi>10.20964/2017.03.16</doi><tpages>15</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1452-3981 |
ispartof | International journal of electrochemical science, 2017-03, Vol.12 (3), p.2329-2343 |
issn | 1452-3981 1452-3981 |
language | eng |
recordid | cdi_crossref_primary_10_20964_2017_03_16 |
source | EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry |
subjects | differential pulse voltammetry (DPV) electrochemical detection nucleobases determination thick-film electrodes |
title | Comparison of Electrochemical Determination of Purines and Pyrimidines by means of Carbon, Graphite and Gold Paste Electrodes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T23%3A03%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Electrochemical%20Determination%20of%20Purines%20and%20Pyrimidines%20by%20means%20of%20Carbon,%20Graphite%20and%20Gold%20Paste%20Electrodes&rft.jtitle=International%20journal%20of%20electrochemical%20science&rft.au=Jankowska-%C5%9Aliwi%C5%84ska,%20Joanna&rft.date=2017-03&rft.volume=12&rft.issue=3&rft.spage=2329&rft.epage=2343&rft.pages=2329-2343&rft.issn=1452-3981&rft.eissn=1452-3981&rft_id=info:doi/10.20964/2017.03.16&rft_dat=%3Celsevier_cross%3ES1452398123056110%3C/elsevier_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S1452398123056110&rfr_iscdi=true |