Design and biomechanical analysis of patient-specific porous tantalum prostheses for knee joint revision surgery

Artificial joint revision surgery, as an increasingly common surgery in orthopedics, often requires patient-specific prostheses to repair the bone defect. Porous tantalum is a good candidate due to its excellent abrasion and corrosion resistance and good osteointegration. Combination of 3D printing...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of bioprinting 2024-08, Vol.9 (4), p.735
Hauptverfasser: Mao, Shilong, Liu, Yang, Wang, Fuyou, He, Peng, Wu, Xianzhe, Ma, Xingshuang, Luo, Yanfeng
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 4
container_start_page 735
container_title International journal of bioprinting
container_volume 9
creator Mao, Shilong
Liu, Yang
Wang, Fuyou
He, Peng
Wu, Xianzhe
Ma, Xingshuang
Luo, Yanfeng
description Artificial joint revision surgery, as an increasingly common surgery in orthopedics, often requires patient-specific prostheses to repair the bone defect. Porous tantalum is a good candidate due to its excellent abrasion and corrosion resistance and good osteointegration. Combination of 3D printing technology and numerical simulation is a promising strategy to design and prepare patient-specific porous prostheses. However, clinical design cases have rarely been reported, especially from the viewpoint of biomechanical matching with the patient's weight and motion and specific bone tissue. This work reports a clinical case on the design and mechanical analysis of 3D-printed porous tantalum prostheses for the knee revision of an 84-year-old male patient. Particularly, standard cylinders of 3D-printed porous tantalum with different pore size and wire diameters were first fabricated and their compressive mechanical properties were measured for following numerical simulation. Subsequently, patientspecific finite element models for the knee prosthesis and the tibia were constructed from the patient's computed tomography data. The maximum von Mises stress and displacement of the prostheses and tibia and the maximum compressive strain of the tibia were numerically simulated under two loading conditions by using finite element analysis software ABAQUS. Finally, by comparing the simulated data to the biomechanical requirements for the prosthesis and the tibia, a patient-specific porous tantalum knee joint prosthesis with a pore diameter of 600 μm and a wire diameter of 900 μm was determined. The Young's modulus (5719.32 ± 100.61 MPa) and yield strength (172.71 ± 1.67 MPa) of the prosthesis can produce both sufficient mechanical support and biomechanical stimulation to the tibia. This work provides a useful guidance for designing and evaluating a patient-specific porous tantalum prosthesis.
doi_str_mv 10.18063/ijb.735
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_18063_ijb_735</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_18063_ijb_735</sourcerecordid><originalsourceid>FETCH-LOGICAL-c191t-e9c055f9af5b3d60bdf767869fce1d47797434dedb482b713bea26234807dfa63</originalsourceid><addsrcrecordid>eNotkEtLAzEYRYMoWLTgT8jSzdS8ZpJZSn1CwY2uhzy-tKnTZEhSof_eQbu6l7O4XA5Cd5SsqCIdfwh7s5K8vUALJphoFCHs8tylZPwaLUvZk5kqSihXCzQ9QQnbiHV02IR0ALvTMVg9zkSPpxIKTh5PugaItSkT2OCDxVPK6Vhw1bHq8XjAU06l7qBAwT5l_B0B8D6FWHGGn1BCirgc8xby6RZdeT0WWJ7zBn29PH-u35rNx-v7-nHTWNrT2kBvSdv6XvvWcNcR47zspOp6b4E6IWUvBRcOnBGKGUm5Ac06xoUi0nnd8Rt0_79r52slgx-mHA46nwZKhj9ZwyxrmGXxX1cMX7s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Design and biomechanical analysis of patient-specific porous tantalum prostheses for knee joint revision surgery</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central Open Access</source><source>PubMed Central</source><creator>Mao, Shilong ; Liu, Yang ; Wang, Fuyou ; He, Peng ; Wu, Xianzhe ; Ma, Xingshuang ; Luo, Yanfeng</creator><creatorcontrib>Mao, Shilong ; Liu, Yang ; Wang, Fuyou ; He, Peng ; Wu, Xianzhe ; Ma, Xingshuang ; Luo, Yanfeng</creatorcontrib><description>Artificial joint revision surgery, as an increasingly common surgery in orthopedics, often requires patient-specific prostheses to repair the bone defect. Porous tantalum is a good candidate due to its excellent abrasion and corrosion resistance and good osteointegration. Combination of 3D printing technology and numerical simulation is a promising strategy to design and prepare patient-specific porous prostheses. However, clinical design cases have rarely been reported, especially from the viewpoint of biomechanical matching with the patient's weight and motion and specific bone tissue. This work reports a clinical case on the design and mechanical analysis of 3D-printed porous tantalum prostheses for the knee revision of an 84-year-old male patient. Particularly, standard cylinders of 3D-printed porous tantalum with different pore size and wire diameters were first fabricated and their compressive mechanical properties were measured for following numerical simulation. Subsequently, patientspecific finite element models for the knee prosthesis and the tibia were constructed from the patient's computed tomography data. The maximum von Mises stress and displacement of the prostheses and tibia and the maximum compressive strain of the tibia were numerically simulated under two loading conditions by using finite element analysis software ABAQUS. Finally, by comparing the simulated data to the biomechanical requirements for the prosthesis and the tibia, a patient-specific porous tantalum knee joint prosthesis with a pore diameter of 600 μm and a wire diameter of 900 μm was determined. The Young's modulus (5719.32 ± 100.61 MPa) and yield strength (172.71 ± 1.67 MPa) of the prosthesis can produce both sufficient mechanical support and biomechanical stimulation to the tibia. This work provides a useful guidance for designing and evaluating a patient-specific porous tantalum prosthesis.</description><identifier>ISSN: 2424-7723</identifier><identifier>EISSN: 2424-8002</identifier><identifier>DOI: 10.18063/ijb.735</identifier><language>eng</language><ispartof>International journal of bioprinting, 2024-08, Vol.9 (4), p.735</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c191t-e9c055f9af5b3d60bdf767869fce1d47797434dedb482b713bea26234807dfa63</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Mao, Shilong</creatorcontrib><creatorcontrib>Liu, Yang</creatorcontrib><creatorcontrib>Wang, Fuyou</creatorcontrib><creatorcontrib>He, Peng</creatorcontrib><creatorcontrib>Wu, Xianzhe</creatorcontrib><creatorcontrib>Ma, Xingshuang</creatorcontrib><creatorcontrib>Luo, Yanfeng</creatorcontrib><title>Design and biomechanical analysis of patient-specific porous tantalum prostheses for knee joint revision surgery</title><title>International journal of bioprinting</title><description>Artificial joint revision surgery, as an increasingly common surgery in orthopedics, often requires patient-specific prostheses to repair the bone defect. Porous tantalum is a good candidate due to its excellent abrasion and corrosion resistance and good osteointegration. Combination of 3D printing technology and numerical simulation is a promising strategy to design and prepare patient-specific porous prostheses. However, clinical design cases have rarely been reported, especially from the viewpoint of biomechanical matching with the patient's weight and motion and specific bone tissue. This work reports a clinical case on the design and mechanical analysis of 3D-printed porous tantalum prostheses for the knee revision of an 84-year-old male patient. Particularly, standard cylinders of 3D-printed porous tantalum with different pore size and wire diameters were first fabricated and their compressive mechanical properties were measured for following numerical simulation. Subsequently, patientspecific finite element models for the knee prosthesis and the tibia were constructed from the patient's computed tomography data. The maximum von Mises stress and displacement of the prostheses and tibia and the maximum compressive strain of the tibia were numerically simulated under two loading conditions by using finite element analysis software ABAQUS. Finally, by comparing the simulated data to the biomechanical requirements for the prosthesis and the tibia, a patient-specific porous tantalum knee joint prosthesis with a pore diameter of 600 μm and a wire diameter of 900 μm was determined. The Young's modulus (5719.32 ± 100.61 MPa) and yield strength (172.71 ± 1.67 MPa) of the prosthesis can produce both sufficient mechanical support and biomechanical stimulation to the tibia. This work provides a useful guidance for designing and evaluating a patient-specific porous tantalum prosthesis.</description><issn>2424-7723</issn><issn>2424-8002</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNotkEtLAzEYRYMoWLTgT8jSzdS8ZpJZSn1CwY2uhzy-tKnTZEhSof_eQbu6l7O4XA5Cd5SsqCIdfwh7s5K8vUALJphoFCHs8tylZPwaLUvZk5kqSihXCzQ9QQnbiHV02IR0ALvTMVg9zkSPpxIKTh5PugaItSkT2OCDxVPK6Vhw1bHq8XjAU06l7qBAwT5l_B0B8D6FWHGGn1BCirgc8xby6RZdeT0WWJ7zBn29PH-u35rNx-v7-nHTWNrT2kBvSdv6XvvWcNcR47zspOp6b4E6IWUvBRcOnBGKGUm5Ac06xoUi0nnd8Rt0_79r52slgx-mHA46nwZKhj9ZwyxrmGXxX1cMX7s</recordid><startdate>20240801</startdate><enddate>20240801</enddate><creator>Mao, Shilong</creator><creator>Liu, Yang</creator><creator>Wang, Fuyou</creator><creator>He, Peng</creator><creator>Wu, Xianzhe</creator><creator>Ma, Xingshuang</creator><creator>Luo, Yanfeng</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20240801</creationdate><title>Design and biomechanical analysis of patient-specific porous tantalum prostheses for knee joint revision surgery</title><author>Mao, Shilong ; Liu, Yang ; Wang, Fuyou ; He, Peng ; Wu, Xianzhe ; Ma, Xingshuang ; Luo, Yanfeng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c191t-e9c055f9af5b3d60bdf767869fce1d47797434dedb482b713bea26234807dfa63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Mao, Shilong</creatorcontrib><creatorcontrib>Liu, Yang</creatorcontrib><creatorcontrib>Wang, Fuyou</creatorcontrib><creatorcontrib>He, Peng</creatorcontrib><creatorcontrib>Wu, Xianzhe</creatorcontrib><creatorcontrib>Ma, Xingshuang</creatorcontrib><creatorcontrib>Luo, Yanfeng</creatorcontrib><collection>CrossRef</collection><jtitle>International journal of bioprinting</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mao, Shilong</au><au>Liu, Yang</au><au>Wang, Fuyou</au><au>He, Peng</au><au>Wu, Xianzhe</au><au>Ma, Xingshuang</au><au>Luo, Yanfeng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and biomechanical analysis of patient-specific porous tantalum prostheses for knee joint revision surgery</atitle><jtitle>International journal of bioprinting</jtitle><date>2024-08-01</date><risdate>2024</risdate><volume>9</volume><issue>4</issue><spage>735</spage><pages>735-</pages><issn>2424-7723</issn><eissn>2424-8002</eissn><abstract>Artificial joint revision surgery, as an increasingly common surgery in orthopedics, often requires patient-specific prostheses to repair the bone defect. Porous tantalum is a good candidate due to its excellent abrasion and corrosion resistance and good osteointegration. Combination of 3D printing technology and numerical simulation is a promising strategy to design and prepare patient-specific porous prostheses. However, clinical design cases have rarely been reported, especially from the viewpoint of biomechanical matching with the patient's weight and motion and specific bone tissue. This work reports a clinical case on the design and mechanical analysis of 3D-printed porous tantalum prostheses for the knee revision of an 84-year-old male patient. Particularly, standard cylinders of 3D-printed porous tantalum with different pore size and wire diameters were first fabricated and their compressive mechanical properties were measured for following numerical simulation. Subsequently, patientspecific finite element models for the knee prosthesis and the tibia were constructed from the patient's computed tomography data. The maximum von Mises stress and displacement of the prostheses and tibia and the maximum compressive strain of the tibia were numerically simulated under two loading conditions by using finite element analysis software ABAQUS. Finally, by comparing the simulated data to the biomechanical requirements for the prosthesis and the tibia, a patient-specific porous tantalum knee joint prosthesis with a pore diameter of 600 μm and a wire diameter of 900 μm was determined. The Young's modulus (5719.32 ± 100.61 MPa) and yield strength (172.71 ± 1.67 MPa) of the prosthesis can produce both sufficient mechanical support and biomechanical stimulation to the tibia. This work provides a useful guidance for designing and evaluating a patient-specific porous tantalum prosthesis.</abstract><doi>10.18063/ijb.735</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2424-7723
ispartof International journal of bioprinting, 2024-08, Vol.9 (4), p.735
issn 2424-7723
2424-8002
language eng
recordid cdi_crossref_primary_10_18063_ijb_735
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central Open Access; PubMed Central
title Design and biomechanical analysis of patient-specific porous tantalum prostheses for knee joint revision surgery
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T03%3A04%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20biomechanical%20analysis%20of%20patient-specific%20porous%20tantalum%20prostheses%20for%20knee%20joint%20revision%20surgery&rft.jtitle=International%20journal%20of%20bioprinting&rft.au=Mao,%20Shilong&rft.date=2024-08-01&rft.volume=9&rft.issue=4&rft.spage=735&rft.pages=735-&rft.issn=2424-7723&rft.eissn=2424-8002&rft_id=info:doi/10.18063/ijb.735&rft_dat=%3Ccrossref%3E10_18063_ijb_735%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true