The Validity and the Reliability of Trunk Flexion and Extension Muscle Strength Measurements in the Sitting Position

[Purpose] The purpose of this study was to examine the validity and the reliability of trunk flexion and extension muscle strength measurements made by a hand-held dynamometer (HHD) in the sitting position. [Subjects and Methods] Thirty-four healthy adults were subjects. Measurements made by the HHD...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Rigaku ryoho kagaku 2015, Vol.30(5), pp.707-712
Hauptverfasser: SAWA, Kouta, NAKAMURA, Manabu, TESHIMA, Masato, HIRANO, Masahiro, KATOH, Munenori
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 712
container_issue 5
container_start_page 707
container_title Rigaku ryoho kagaku
container_volume 30
creator SAWA, Kouta
NAKAMURA, Manabu
TESHIMA, Masato
HIRANO, Masahiro
KATOH, Munenori
description [Purpose] The purpose of this study was to examine the validity and the reliability of trunk flexion and extension muscle strength measurements made by a hand-held dynamometer (HHD) in the sitting position. [Subjects and Methods] Thirty-four healthy adults were subjects. Measurements made by the HHD were compared with those made by isokinetic strength measurement equipment (ISME). The validity was investigated with Pearson’s product moment correlation coefficient, inter-rater and intra-rater relative reliabilities were estimated using the intraclass correlation coefficients (ICC), and the absolute reliability was determined using Bland-Altman analysis. [Results] HHD and ISME measurements showed a significant correlation, and ICC values were high. The trunk extension muscle strength showed a large bias in Bland-Altman analysis. [Conclusion] Clinical applications of HDD measurements is possible with due consideration of the measurement error.
doi_str_mv 10.1589/rika.30.707
format Article
fullrecord <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1589_rika_30_707</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_rika_30_5_30_707_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1987-43ad2b9147ee888dd381757fb4e506f65eb54ff9d5481457b3d02c9066d9fd953</originalsourceid><addsrcrecordid>eNo9kFFLwzAUhYMoOOae_AN5l86kSZr0RZCxqbChuOlrSZvbLa5LJclg-_e2buzpcs_9zoF7ELqnZEyFyh-93eoxI2NJ5BUapJzxJFVEXqMBZZwmNMvkLRqFYEvCuRS5VNkAxdUG8LdurLHxiLUzOHbCJzRWl7bptbbGK793Wzxr4GBb9w9NDxFc6LfFPlQN4GX04NZxgxegw97DDlwM2Lr_uKWN0bo1_miDjZ3pDt3UugkwOs8h-ppNV5PXZP7-8jZ5nicVzZVMONMmLXPKJYBSyhimqBSyLjkIktWZgFLwus6N4IpyIUtmSFrlJMtMXptcsCF6OOVWvg3BQ138ervT_lhQUvSdFX1nBSNF11lHP53onxD1Gi6s9tF2L15YcTZcDtVG-wIc-wO9wHgN</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>The Validity and the Reliability of Trunk Flexion and Extension Muscle Strength Measurements in the Sitting Position</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>SAWA, Kouta ; NAKAMURA, Manabu ; TESHIMA, Masato ; HIRANO, Masahiro ; KATOH, Munenori</creator><creatorcontrib>SAWA, Kouta ; NAKAMURA, Manabu ; TESHIMA, Masato ; HIRANO, Masahiro ; KATOH, Munenori</creatorcontrib><description>[Purpose] The purpose of this study was to examine the validity and the reliability of trunk flexion and extension muscle strength measurements made by a hand-held dynamometer (HHD) in the sitting position. [Subjects and Methods] Thirty-four healthy adults were subjects. Measurements made by the HHD were compared with those made by isokinetic strength measurement equipment (ISME). The validity was investigated with Pearson’s product moment correlation coefficient, inter-rater and intra-rater relative reliabilities were estimated using the intraclass correlation coefficients (ICC), and the absolute reliability was determined using Bland-Altman analysis. [Results] HHD and ISME measurements showed a significant correlation, and ICC values were high. The trunk extension muscle strength showed a large bias in Bland-Altman analysis. [Conclusion] Clinical applications of HDD measurements is possible with due consideration of the measurement error.</description><identifier>ISSN: 1341-1667</identifier><identifier>EISSN: 2434-2807</identifier><identifier>DOI: 10.1589/rika.30.707</identifier><language>eng ; jpn</language><publisher>The Society of Physical Therapy Science</publisher><subject>reliability ; trunk muscle strength ; validity</subject><ispartof>Rigakuryoho Kagaku, 2015, Vol.30(5), pp.707-712</ispartof><rights>2015 by the Society of Physical Therapy Science</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1987-43ad2b9147ee888dd381757fb4e506f65eb54ff9d5481457b3d02c9066d9fd953</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,4010,27900,27901,27902</link.rule.ids></links><search><creatorcontrib>SAWA, Kouta</creatorcontrib><creatorcontrib>NAKAMURA, Manabu</creatorcontrib><creatorcontrib>TESHIMA, Masato</creatorcontrib><creatorcontrib>HIRANO, Masahiro</creatorcontrib><creatorcontrib>KATOH, Munenori</creatorcontrib><title>The Validity and the Reliability of Trunk Flexion and Extension Muscle Strength Measurements in the Sitting Position</title><title>Rigaku ryoho kagaku</title><addtitle>Rigakuryoho Kagaku</addtitle><description>[Purpose] The purpose of this study was to examine the validity and the reliability of trunk flexion and extension muscle strength measurements made by a hand-held dynamometer (HHD) in the sitting position. [Subjects and Methods] Thirty-four healthy adults were subjects. Measurements made by the HHD were compared with those made by isokinetic strength measurement equipment (ISME). The validity was investigated with Pearson’s product moment correlation coefficient, inter-rater and intra-rater relative reliabilities were estimated using the intraclass correlation coefficients (ICC), and the absolute reliability was determined using Bland-Altman analysis. [Results] HHD and ISME measurements showed a significant correlation, and ICC values were high. The trunk extension muscle strength showed a large bias in Bland-Altman analysis. [Conclusion] Clinical applications of HDD measurements is possible with due consideration of the measurement error.</description><subject>reliability</subject><subject>trunk muscle strength</subject><subject>validity</subject><issn>1341-1667</issn><issn>2434-2807</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNo9kFFLwzAUhYMoOOae_AN5l86kSZr0RZCxqbChuOlrSZvbLa5LJclg-_e2buzpcs_9zoF7ELqnZEyFyh-93eoxI2NJ5BUapJzxJFVEXqMBZZwmNMvkLRqFYEvCuRS5VNkAxdUG8LdurLHxiLUzOHbCJzRWl7bptbbGK793Wzxr4GBb9w9NDxFc6LfFPlQN4GX04NZxgxegw97DDlwM2Lr_uKWN0bo1_miDjZ3pDt3UugkwOs8h-ppNV5PXZP7-8jZ5nicVzZVMONMmLXPKJYBSyhimqBSyLjkIktWZgFLwus6N4IpyIUtmSFrlJMtMXptcsCF6OOVWvg3BQ138ervT_lhQUvSdFX1nBSNF11lHP53onxD1Gi6s9tF2L15YcTZcDtVG-wIc-wO9wHgN</recordid><startdate>2015</startdate><enddate>2015</enddate><creator>SAWA, Kouta</creator><creator>NAKAMURA, Manabu</creator><creator>TESHIMA, Masato</creator><creator>HIRANO, Masahiro</creator><creator>KATOH, Munenori</creator><general>The Society of Physical Therapy Science</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2015</creationdate><title>The Validity and the Reliability of Trunk Flexion and Extension Muscle Strength Measurements in the Sitting Position</title><author>SAWA, Kouta ; NAKAMURA, Manabu ; TESHIMA, Masato ; HIRANO, Masahiro ; KATOH, Munenori</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1987-43ad2b9147ee888dd381757fb4e506f65eb54ff9d5481457b3d02c9066d9fd953</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2015</creationdate><topic>reliability</topic><topic>trunk muscle strength</topic><topic>validity</topic><toplevel>online_resources</toplevel><creatorcontrib>SAWA, Kouta</creatorcontrib><creatorcontrib>NAKAMURA, Manabu</creatorcontrib><creatorcontrib>TESHIMA, Masato</creatorcontrib><creatorcontrib>HIRANO, Masahiro</creatorcontrib><creatorcontrib>KATOH, Munenori</creatorcontrib><collection>CrossRef</collection><jtitle>Rigaku ryoho kagaku</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SAWA, Kouta</au><au>NAKAMURA, Manabu</au><au>TESHIMA, Masato</au><au>HIRANO, Masahiro</au><au>KATOH, Munenori</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Validity and the Reliability of Trunk Flexion and Extension Muscle Strength Measurements in the Sitting Position</atitle><jtitle>Rigaku ryoho kagaku</jtitle><addtitle>Rigakuryoho Kagaku</addtitle><date>2015</date><risdate>2015</risdate><volume>30</volume><issue>5</issue><spage>707</spage><epage>712</epage><pages>707-712</pages><issn>1341-1667</issn><eissn>2434-2807</eissn><abstract>[Purpose] The purpose of this study was to examine the validity and the reliability of trunk flexion and extension muscle strength measurements made by a hand-held dynamometer (HHD) in the sitting position. [Subjects and Methods] Thirty-four healthy adults were subjects. Measurements made by the HHD were compared with those made by isokinetic strength measurement equipment (ISME). The validity was investigated with Pearson’s product moment correlation coefficient, inter-rater and intra-rater relative reliabilities were estimated using the intraclass correlation coefficients (ICC), and the absolute reliability was determined using Bland-Altman analysis. [Results] HHD and ISME measurements showed a significant correlation, and ICC values were high. The trunk extension muscle strength showed a large bias in Bland-Altman analysis. [Conclusion] Clinical applications of HDD measurements is possible with due consideration of the measurement error.</abstract><pub>The Society of Physical Therapy Science</pub><doi>10.1589/rika.30.707</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1341-1667
ispartof Rigakuryoho Kagaku, 2015, Vol.30(5), pp.707-712
issn 1341-1667
2434-2807
language eng ; jpn
recordid cdi_crossref_primary_10_1589_rika_30_707
source J-STAGE Free; EZB-FREE-00999 freely available EZB journals
subjects reliability
trunk muscle strength
validity
title The Validity and the Reliability of Trunk Flexion and Extension Muscle Strength Measurements in the Sitting Position
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T23%3A22%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Validity%20and%20the%20Reliability%20of%20Trunk%20Flexion%20and%20Extension%20Muscle%20Strength%20Measurements%20in%20the%20Sitting%20Position&rft.jtitle=Rigaku%20ryoho%20kagaku&rft.au=SAWA,%20Kouta&rft.date=2015&rft.volume=30&rft.issue=5&rft.spage=707&rft.epage=712&rft.pages=707-712&rft.issn=1341-1667&rft.eissn=2434-2807&rft_id=info:doi/10.1589/rika.30.707&rft_dat=%3Cjstage_cross%3Earticle_rika_30_5_30_707_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true