Pemberton Sign

We report a case of intrathoracic goiter with positive Pemberton sign. Conventional spirometry did not show abnormalities, but arm elevation spirometry with flow-volume loops revealed expiratory flow limitation with a plateau. Clinicians should consider repeating flow-volume loops with arm elevation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chest 2015-12, Vol.148 (6), p.e168-e170
Hauptverfasser: Resende, Patrícia Naves, MD, de Menezes, Marcelo Bezerra, MD, Silva, Geruza Alves, MD, Vianna, Elcio Oliveira, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e170
container_issue 6
container_start_page e168
container_title Chest
container_volume 148
creator Resende, Patrícia Naves, MD
de Menezes, Marcelo Bezerra, MD
Silva, Geruza Alves, MD
Vianna, Elcio Oliveira, MD
description We report a case of intrathoracic goiter with positive Pemberton sign. Conventional spirometry did not show abnormalities, but arm elevation spirometry with flow-volume loops revealed expiratory flow limitation with a plateau. Clinicians should consider repeating flow-volume loops with arm elevation in all cases of intrathoracic goiter with initially normal loops.
doi_str_mv 10.1378/chest.15-0700
format Article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1378_chest_15_0700</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0012369215501232</els_id><sourcerecordid>S0012369215501232</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1410-6652347b75dad938bd6823a141e5dc597013158e0612a1ee1244fcefd20edd5d3</originalsourceid><addsrcrecordid>eNp1kEFLxDAQhYMoWFe9efcPZJ1JmqS9CLLoKiworJ5Dm0w1a7eVpAr7721dT4KnmWHeG-Z7jF0gzFGa4sq9URrmqDgYgAOWYSmRS5XLQ5YBoOBSl-KYnaS0gXHGUmfs_Im2NcWh7y7X4bU7ZUdN1SY6-60z9nJ3-7y456vH5cPiZsUd5ghcayVkbmqjfOVLWdReF0JW446Ud6o0gBJVQaBRVEiEIs8bR40XQN4rL2eM7--62KcUqbEfMWyruLMIdoKxPzAWlZ1gRr3Z62l86itQtMkF6hz5EMkN1vfhX-f1H6drQxdc1b7TjtKm_4zdSGrRJmHBrqegppxQqakT8hvlB2MX</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Pemberton Sign</title><source>Journals@Ovid Complete</source><source>Alma/SFX Local Collection</source><creator>Resende, Patrícia Naves, MD ; de Menezes, Marcelo Bezerra, MD ; Silva, Geruza Alves, MD ; Vianna, Elcio Oliveira, MD</creator><creatorcontrib>Resende, Patrícia Naves, MD ; de Menezes, Marcelo Bezerra, MD ; Silva, Geruza Alves, MD ; Vianna, Elcio Oliveira, MD</creatorcontrib><description>We report a case of intrathoracic goiter with positive Pemberton sign. Conventional spirometry did not show abnormalities, but arm elevation spirometry with flow-volume loops revealed expiratory flow limitation with a plateau. Clinicians should consider repeating flow-volume loops with arm elevation in all cases of intrathoracic goiter with initially normal loops.</description><identifier>ISSN: 0012-3692</identifier><identifier>EISSN: 1931-3543</identifier><identifier>DOI: 10.1378/chest.15-0700</identifier><language>eng</language><publisher>Elsevier Inc</publisher><subject>Pulmonary/Respiratory</subject><ispartof>Chest, 2015-12, Vol.148 (6), p.e168-e170</ispartof><rights>The American College of Chest Physicians</rights><rights>2015 The American College of Chest Physicians</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1410-6652347b75dad938bd6823a141e5dc597013158e0612a1ee1244fcefd20edd5d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27931,27932</link.rule.ids></links><search><creatorcontrib>Resende, Patrícia Naves, MD</creatorcontrib><creatorcontrib>de Menezes, Marcelo Bezerra, MD</creatorcontrib><creatorcontrib>Silva, Geruza Alves, MD</creatorcontrib><creatorcontrib>Vianna, Elcio Oliveira, MD</creatorcontrib><title>Pemberton Sign</title><title>Chest</title><description>We report a case of intrathoracic goiter with positive Pemberton sign. Conventional spirometry did not show abnormalities, but arm elevation spirometry with flow-volume loops revealed expiratory flow limitation with a plateau. Clinicians should consider repeating flow-volume loops with arm elevation in all cases of intrathoracic goiter with initially normal loops.</description><subject>Pulmonary/Respiratory</subject><issn>0012-3692</issn><issn>1931-3543</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp1kEFLxDAQhYMoWFe9efcPZJ1JmqS9CLLoKiworJ5Dm0w1a7eVpAr7721dT4KnmWHeG-Z7jF0gzFGa4sq9URrmqDgYgAOWYSmRS5XLQ5YBoOBSl-KYnaS0gXHGUmfs_Im2NcWh7y7X4bU7ZUdN1SY6-60z9nJ3-7y456vH5cPiZsUd5ghcayVkbmqjfOVLWdReF0JW446Ud6o0gBJVQaBRVEiEIs8bR40XQN4rL2eM7--62KcUqbEfMWyruLMIdoKxPzAWlZ1gRr3Z62l86itQtMkF6hz5EMkN1vfhX-f1H6drQxdc1b7TjtKm_4zdSGrRJmHBrqegppxQqakT8hvlB2MX</recordid><startdate>201512</startdate><enddate>201512</enddate><creator>Resende, Patrícia Naves, MD</creator><creator>de Menezes, Marcelo Bezerra, MD</creator><creator>Silva, Geruza Alves, MD</creator><creator>Vianna, Elcio Oliveira, MD</creator><general>Elsevier Inc</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201512</creationdate><title>Pemberton Sign</title><author>Resende, Patrícia Naves, MD ; de Menezes, Marcelo Bezerra, MD ; Silva, Geruza Alves, MD ; Vianna, Elcio Oliveira, MD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1410-6652347b75dad938bd6823a141e5dc597013158e0612a1ee1244fcefd20edd5d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Pulmonary/Respiratory</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Resende, Patrícia Naves, MD</creatorcontrib><creatorcontrib>de Menezes, Marcelo Bezerra, MD</creatorcontrib><creatorcontrib>Silva, Geruza Alves, MD</creatorcontrib><creatorcontrib>Vianna, Elcio Oliveira, MD</creatorcontrib><collection>CrossRef</collection><jtitle>Chest</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Resende, Patrícia Naves, MD</au><au>de Menezes, Marcelo Bezerra, MD</au><au>Silva, Geruza Alves, MD</au><au>Vianna, Elcio Oliveira, MD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pemberton Sign</atitle><jtitle>Chest</jtitle><date>2015-12</date><risdate>2015</risdate><volume>148</volume><issue>6</issue><spage>e168</spage><epage>e170</epage><pages>e168-e170</pages><issn>0012-3692</issn><eissn>1931-3543</eissn><abstract>We report a case of intrathoracic goiter with positive Pemberton sign. Conventional spirometry did not show abnormalities, but arm elevation spirometry with flow-volume loops revealed expiratory flow limitation with a plateau. Clinicians should consider repeating flow-volume loops with arm elevation in all cases of intrathoracic goiter with initially normal loops.</abstract><pub>Elsevier Inc</pub><doi>10.1378/chest.15-0700</doi></addata></record>
fulltext fulltext
identifier ISSN: 0012-3692
ispartof Chest, 2015-12, Vol.148 (6), p.e168-e170
issn 0012-3692
1931-3543
language eng
recordid cdi_crossref_primary_10_1378_chest_15_0700
source Journals@Ovid Complete; Alma/SFX Local Collection
subjects Pulmonary/Respiratory
title Pemberton Sign
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-06T09%3A09%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pemberton%20Sign&rft.jtitle=Chest&rft.au=Resende,%20Patr%C3%ADcia%20Naves,%20MD&rft.date=2015-12&rft.volume=148&rft.issue=6&rft.spage=e168&rft.epage=e170&rft.pages=e168-e170&rft.issn=0012-3692&rft.eissn=1931-3543&rft_id=info:doi/10.1378/chest.15-0700&rft_dat=%3Celsevier_cross%3ES0012369215501232%3C/elsevier_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S0012369215501232&rfr_iscdi=true