Calibration Transfer from Pharmaceutical Powder Mixtures to Compacts Using the Prediction Augmented Classical Least Squares (PACLS) Method

This study was designed to assess the potential of transferring a calibration model from pharmaceutical powder mixtures to compacts of identical compositions using prediction augmented classical least squares (PACLS). A 2-factor, 5-level, full-factorial design was used to generate powder mixtures an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied spectroscopy 2012-09, Vol.66 (9), p.1075-1081
Hauptverfasser: Shi, Zhenqi, Igne, Benoît, Bondi, Robert W., Drennen, James K., Anderson, Carl A.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1081
container_issue 9
container_start_page 1075
container_title Applied spectroscopy
container_volume 66
creator Shi, Zhenqi
Igne, Benoît
Bondi, Robert W.
Drennen, James K.
Anderson, Carl A.
description This study was designed to assess the potential of transferring a calibration model from pharmaceutical powder mixtures to compacts of identical compositions using prediction augmented classical least squares (PACLS). A 2-factor, 5-level, full-factorial design was used to generate powder mixtures and compacts with a variety of formulation compositions. Spectra representative of powder mixtures were used for calibration, while spectra collected on both unrelaxed and relaxed compacts were used as the prediction dataset. The CLS augmentation strategy was to add empirically determined spectral shapes representative of the density differences between powder mixtures and compacts to the original K matrix. The performance of PACLS was compared to other commonly used modeling techniques, including classical least squares (CLS) and partial least squares (PLS) with and without spectral pretreatments and standardization. Significantly improved prediction performance (p < 0.05) was demonstrated by PACLS approaches compared to other techniques. This work demonstrated a technique to orthogonalize the spectral differences between powder and compact samples, allowing the prediction of chemical properties in compacts. Specific precautions for applying PACLS in a calibration transfer from powder mixtures to compacts are also discussed.
doi_str_mv 10.1366/11-06501
format Article
fullrecord <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1366_11_06501</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1366_11-06501</sage_id><sourcerecordid>10.1366_11-06501</sourcerecordid><originalsourceid>FETCH-LOGICAL-c257t-d40acc2ca77a792e505cf79738be121089f28f834066391894f2cb6351f40c303</originalsourceid><addsrcrecordid>eNplkM1Kw0AUhQdRsFbBR5iNUBfRO5lMfpYl-ActBtquw-1kpk1JMnVmgvoKPrVp687V4XI-Pi6HkFsGD4zH8SNjAcQC2BkZsSziARcczskIAHiQQJhekivndsMpMi5G5CfHpl5b9LXp6NJi57SyVFvT0mKLtkWpel9LbGhhPquhmtdfvrfKUW9obto9Su_oytXdhvqtooVVVS2Ptmm_aVXnVUXzBp07SmYKnaeLjx4PikkxzWeLezpXfmuqa3KhsXHq5i_HZPX8tMxfg9n7y1s-nQUyFIkPqghQylBikmCShUqAkDrJEp6uFQsZpJkOU53yCOKYZyzNIh3KdcwF0xFIDnxMJievtMY5q3S5t3WL9rtkUB42LBkrjxsO6N0JdbhR5c70ths--8_9AiuYb6k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Calibration Transfer from Pharmaceutical Powder Mixtures to Compacts Using the Prediction Augmented Classical Least Squares (PACLS) Method</title><source>SAGE Complete</source><creator>Shi, Zhenqi ; Igne, Benoît ; Bondi, Robert W. ; Drennen, James K. ; Anderson, Carl A.</creator><creatorcontrib>Shi, Zhenqi ; Igne, Benoît ; Bondi, Robert W. ; Drennen, James K. ; Anderson, Carl A.</creatorcontrib><description>This study was designed to assess the potential of transferring a calibration model from pharmaceutical powder mixtures to compacts of identical compositions using prediction augmented classical least squares (PACLS). A 2-factor, 5-level, full-factorial design was used to generate powder mixtures and compacts with a variety of formulation compositions. Spectra representative of powder mixtures were used for calibration, while spectra collected on both unrelaxed and relaxed compacts were used as the prediction dataset. The CLS augmentation strategy was to add empirically determined spectral shapes representative of the density differences between powder mixtures and compacts to the original K matrix. The performance of PACLS was compared to other commonly used modeling techniques, including classical least squares (CLS) and partial least squares (PLS) with and without spectral pretreatments and standardization. Significantly improved prediction performance (p &lt; 0.05) was demonstrated by PACLS approaches compared to other techniques. This work demonstrated a technique to orthogonalize the spectral differences between powder and compact samples, allowing the prediction of chemical properties in compacts. Specific precautions for applying PACLS in a calibration transfer from powder mixtures to compacts are also discussed.</description><identifier>ISSN: 0003-7028</identifier><identifier>EISSN: 1943-3530</identifier><identifier>DOI: 10.1366/11-06501</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Applied spectroscopy, 2012-09, Vol.66 (9), p.1075-1081</ispartof><rights>2012 Society for Applied Spectroscopy</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c257t-d40acc2ca77a792e505cf79738be121089f28f834066391894f2cb6351f40c303</citedby><cites>FETCH-LOGICAL-c257t-d40acc2ca77a792e505cf79738be121089f28f834066391894f2cb6351f40c303</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1366/11-06501$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1366/11-06501$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,776,780,21798,27901,27902,43597,43598</link.rule.ids></links><search><creatorcontrib>Shi, Zhenqi</creatorcontrib><creatorcontrib>Igne, Benoît</creatorcontrib><creatorcontrib>Bondi, Robert W.</creatorcontrib><creatorcontrib>Drennen, James K.</creatorcontrib><creatorcontrib>Anderson, Carl A.</creatorcontrib><title>Calibration Transfer from Pharmaceutical Powder Mixtures to Compacts Using the Prediction Augmented Classical Least Squares (PACLS) Method</title><title>Applied spectroscopy</title><description>This study was designed to assess the potential of transferring a calibration model from pharmaceutical powder mixtures to compacts of identical compositions using prediction augmented classical least squares (PACLS). A 2-factor, 5-level, full-factorial design was used to generate powder mixtures and compacts with a variety of formulation compositions. Spectra representative of powder mixtures were used for calibration, while spectra collected on both unrelaxed and relaxed compacts were used as the prediction dataset. The CLS augmentation strategy was to add empirically determined spectral shapes representative of the density differences between powder mixtures and compacts to the original K matrix. The performance of PACLS was compared to other commonly used modeling techniques, including classical least squares (CLS) and partial least squares (PLS) with and without spectral pretreatments and standardization. Significantly improved prediction performance (p &lt; 0.05) was demonstrated by PACLS approaches compared to other techniques. This work demonstrated a technique to orthogonalize the spectral differences between powder and compact samples, allowing the prediction of chemical properties in compacts. Specific precautions for applying PACLS in a calibration transfer from powder mixtures to compacts are also discussed.</description><issn>0003-7028</issn><issn>1943-3530</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNplkM1Kw0AUhQdRsFbBR5iNUBfRO5lMfpYl-ActBtquw-1kpk1JMnVmgvoKPrVp687V4XI-Pi6HkFsGD4zH8SNjAcQC2BkZsSziARcczskIAHiQQJhekivndsMpMi5G5CfHpl5b9LXp6NJi57SyVFvT0mKLtkWpel9LbGhhPquhmtdfvrfKUW9obto9Su_oytXdhvqtooVVVS2Ptmm_aVXnVUXzBp07SmYKnaeLjx4PikkxzWeLezpXfmuqa3KhsXHq5i_HZPX8tMxfg9n7y1s-nQUyFIkPqghQylBikmCShUqAkDrJEp6uFQsZpJkOU53yCOKYZyzNIh3KdcwF0xFIDnxMJievtMY5q3S5t3WL9rtkUB42LBkrjxsO6N0JdbhR5c70ths--8_9AiuYb6k</recordid><startdate>201209</startdate><enddate>201209</enddate><creator>Shi, Zhenqi</creator><creator>Igne, Benoît</creator><creator>Bondi, Robert W.</creator><creator>Drennen, James K.</creator><creator>Anderson, Carl A.</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201209</creationdate><title>Calibration Transfer from Pharmaceutical Powder Mixtures to Compacts Using the Prediction Augmented Classical Least Squares (PACLS) Method</title><author>Shi, Zhenqi ; Igne, Benoît ; Bondi, Robert W. ; Drennen, James K. ; Anderson, Carl A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c257t-d40acc2ca77a792e505cf79738be121089f28f834066391894f2cb6351f40c303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shi, Zhenqi</creatorcontrib><creatorcontrib>Igne, Benoît</creatorcontrib><creatorcontrib>Bondi, Robert W.</creatorcontrib><creatorcontrib>Drennen, James K.</creatorcontrib><creatorcontrib>Anderson, Carl A.</creatorcontrib><collection>CrossRef</collection><jtitle>Applied spectroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shi, Zhenqi</au><au>Igne, Benoît</au><au>Bondi, Robert W.</au><au>Drennen, James K.</au><au>Anderson, Carl A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibration Transfer from Pharmaceutical Powder Mixtures to Compacts Using the Prediction Augmented Classical Least Squares (PACLS) Method</atitle><jtitle>Applied spectroscopy</jtitle><date>2012-09</date><risdate>2012</risdate><volume>66</volume><issue>9</issue><spage>1075</spage><epage>1081</epage><pages>1075-1081</pages><issn>0003-7028</issn><eissn>1943-3530</eissn><abstract>This study was designed to assess the potential of transferring a calibration model from pharmaceutical powder mixtures to compacts of identical compositions using prediction augmented classical least squares (PACLS). A 2-factor, 5-level, full-factorial design was used to generate powder mixtures and compacts with a variety of formulation compositions. Spectra representative of powder mixtures were used for calibration, while spectra collected on both unrelaxed and relaxed compacts were used as the prediction dataset. The CLS augmentation strategy was to add empirically determined spectral shapes representative of the density differences between powder mixtures and compacts to the original K matrix. The performance of PACLS was compared to other commonly used modeling techniques, including classical least squares (CLS) and partial least squares (PLS) with and without spectral pretreatments and standardization. Significantly improved prediction performance (p &lt; 0.05) was demonstrated by PACLS approaches compared to other techniques. This work demonstrated a technique to orthogonalize the spectral differences between powder and compact samples, allowing the prediction of chemical properties in compacts. Specific precautions for applying PACLS in a calibration transfer from powder mixtures to compacts are also discussed.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1366/11-06501</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-7028
ispartof Applied spectroscopy, 2012-09, Vol.66 (9), p.1075-1081
issn 0003-7028
1943-3530
language eng
recordid cdi_crossref_primary_10_1366_11_06501
source SAGE Complete
title Calibration Transfer from Pharmaceutical Powder Mixtures to Compacts Using the Prediction Augmented Classical Least Squares (PACLS) Method
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T11%3A58%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibration%20Transfer%20from%20Pharmaceutical%20Powder%20Mixtures%20to%20Compacts%20Using%20the%20Prediction%20Augmented%20Classical%20Least%20Squares%20(PACLS)%20Method&rft.jtitle=Applied%20spectroscopy&rft.au=Shi,%20Zhenqi&rft.date=2012-09&rft.volume=66&rft.issue=9&rft.spage=1075&rft.epage=1081&rft.pages=1075-1081&rft.issn=0003-7028&rft.eissn=1943-3530&rft_id=info:doi/10.1366/11-06501&rft_dat=%3Csage_cross%3E10.1366_11-06501%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1366_11-06501&rfr_iscdi=true