Unique Oxygen Analyzer Combining a Dual Emission Probe and a Low-Cost Solid-State Ratiometric Fluorometer
A new oxygen analyzer combining a polymer-encapsulated dual-emission probe and a diode-based ratiometric fluorometer is described. The ratiometric fluorometer was configured to measure the relative fluorescence and phosphorescence intensity of the short-lived singlet and long-lived oxygen-quenchable...
Gespeichert in:
Veröffentlicht in: | Applied spectroscopy 2000-06, Vol.54 (6), p.864-868 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 868 |
---|---|
container_issue | 6 |
container_start_page | 864 |
container_title | Applied spectroscopy |
container_volume | 54 |
creator | Kostov, Yordan Van Houten, Kelly A. Harms, Peter Pilato, Robert S. Rao, Govind |
description | A new oxygen analyzer combining a polymer-encapsulated dual-emission probe and a diode-based ratiometric fluorometer is described. The ratiometric fluorometer was configured to measure the relative fluorescence and phosphorescence intensity of the short-lived singlet and long-lived oxygen-quenchable triplet of [(dppe)Pt{S2C2(CH2CH2–N–2-pyridinium)}](BPh4), where dppe is 1,2-bis(diphenylphosphino)ethane. This luminescent dye was immobilized at 0.3% by weight in cellulose acetate/75% triethylcitrate and cast into a 0.5 mm-thick film. The dye molecule was excited with a blue light-emitting diode (LED) and the singlet and triplet emissions monitored by individual photodiodes at 570 and 680 nm, respectively. Oxygen can be accurately measured without interference from nonanalyte-induced intensity changes by monitoring the relative output of the two photodiodes. The output of the device was linear with oxygen concentration. The PO2(1/2) from the ratio-adapted Stern–Volmer plot was 9.6% oxygen (≈73 torr), offering a dynamic range of 0–90% O2. The device is stable and the oxygen measurements reproducible. Intentional photobleaching of ≈20% of the sensor dye had little effect upon the reproducibility of the oxygen measurements. |
doi_str_mv | 10.1366/0003702001950238 |
format | Article |
fullrecord | <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1366_0003702001950238</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1366_0003702001950238</sage_id><sourcerecordid>10.1366_0003702001950238</sourcerecordid><originalsourceid>FETCH-LOGICAL-c279t-e407664bbde056ac4017864c352baa6f5fa3bedb769beafa699e2172f07192573</originalsourceid><addsrcrecordid>eNp1kM9LwzAYhoMoOKd3j_kHovnRJMtx1E2FwcS5c_nSpiOjbTRp0fnX2zFPgqePl-d9v8OD0C2jd0wodU8pFZpySpmRlIvZGZowkwkipKDnaHLEZOSzS3SV0n6M0gg5QX7b-Y_B4fXXYec6PO-gOXy7iPPQWt_5bocBPwzQ4EXrU_Khwy8xWIehq0ayCp8kD6nHm9D4imx66B1-hd6H1vXRl3jZDCEeg4vX6KKGJrmb3ztF2-XiLX8iq_Xjcz5fkZJr0xOXUa1UZm3lqFRQZpTpmcpKIbkFULWsQVhXWa2MdVCDMsZxpnlNNTNcajFF9PS3jCGl6OriPfoW4qFgtDiqKv6qGifkNEmwc8U-DHHUkP7v_wDMnmkb</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Unique Oxygen Analyzer Combining a Dual Emission Probe and a Low-Cost Solid-State Ratiometric Fluorometer</title><source>SAGE Complete A-Z List</source><creator>Kostov, Yordan ; Van Houten, Kelly A. ; Harms, Peter ; Pilato, Robert S. ; Rao, Govind</creator><creatorcontrib>Kostov, Yordan ; Van Houten, Kelly A. ; Harms, Peter ; Pilato, Robert S. ; Rao, Govind</creatorcontrib><description>A new oxygen analyzer combining a polymer-encapsulated dual-emission probe and a diode-based ratiometric fluorometer is described. The ratiometric fluorometer was configured to measure the relative fluorescence and phosphorescence intensity of the short-lived singlet and long-lived oxygen-quenchable triplet of [(dppe)Pt{S2C2(CH2CH2–N–2-pyridinium)}](BPh4), where dppe is 1,2-bis(diphenylphosphino)ethane. This luminescent dye was immobilized at 0.3% by weight in cellulose acetate/75% triethylcitrate and cast into a 0.5 mm-thick film. The dye molecule was excited with a blue light-emitting diode (LED) and the singlet and triplet emissions monitored by individual photodiodes at 570 and 680 nm, respectively. Oxygen can be accurately measured without interference from nonanalyte-induced intensity changes by monitoring the relative output of the two photodiodes. The output of the device was linear with oxygen concentration. The PO2(1/2) from the ratio-adapted Stern–Volmer plot was 9.6% oxygen (≈73 torr), offering a dynamic range of 0–90% O2. The device is stable and the oxygen measurements reproducible. Intentional photobleaching of ≈20% of the sensor dye had little effect upon the reproducibility of the oxygen measurements.</description><identifier>ISSN: 0003-7028</identifier><identifier>EISSN: 1943-3530</identifier><identifier>DOI: 10.1366/0003702001950238</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Applied spectroscopy, 2000-06, Vol.54 (6), p.864-868</ispartof><rights>2000 Society for Applied Spectroscopy</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c279t-e407664bbde056ac4017864c352baa6f5fa3bedb769beafa699e2172f07192573</citedby><cites>FETCH-LOGICAL-c279t-e407664bbde056ac4017864c352baa6f5fa3bedb769beafa699e2172f07192573</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1366/0003702001950238$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1366/0003702001950238$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21817,27922,27923,43619,43620</link.rule.ids></links><search><creatorcontrib>Kostov, Yordan</creatorcontrib><creatorcontrib>Van Houten, Kelly A.</creatorcontrib><creatorcontrib>Harms, Peter</creatorcontrib><creatorcontrib>Pilato, Robert S.</creatorcontrib><creatorcontrib>Rao, Govind</creatorcontrib><title>Unique Oxygen Analyzer Combining a Dual Emission Probe and a Low-Cost Solid-State Ratiometric Fluorometer</title><title>Applied spectroscopy</title><description>A new oxygen analyzer combining a polymer-encapsulated dual-emission probe and a diode-based ratiometric fluorometer is described. The ratiometric fluorometer was configured to measure the relative fluorescence and phosphorescence intensity of the short-lived singlet and long-lived oxygen-quenchable triplet of [(dppe)Pt{S2C2(CH2CH2–N–2-pyridinium)}](BPh4), where dppe is 1,2-bis(diphenylphosphino)ethane. This luminescent dye was immobilized at 0.3% by weight in cellulose acetate/75% triethylcitrate and cast into a 0.5 mm-thick film. The dye molecule was excited with a blue light-emitting diode (LED) and the singlet and triplet emissions monitored by individual photodiodes at 570 and 680 nm, respectively. Oxygen can be accurately measured without interference from nonanalyte-induced intensity changes by monitoring the relative output of the two photodiodes. The output of the device was linear with oxygen concentration. The PO2(1/2) from the ratio-adapted Stern–Volmer plot was 9.6% oxygen (≈73 torr), offering a dynamic range of 0–90% O2. The device is stable and the oxygen measurements reproducible. Intentional photobleaching of ≈20% of the sensor dye had little effect upon the reproducibility of the oxygen measurements.</description><issn>0003-7028</issn><issn>1943-3530</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNp1kM9LwzAYhoMoOKd3j_kHovnRJMtx1E2FwcS5c_nSpiOjbTRp0fnX2zFPgqePl-d9v8OD0C2jd0wodU8pFZpySpmRlIvZGZowkwkipKDnaHLEZOSzS3SV0n6M0gg5QX7b-Y_B4fXXYec6PO-gOXy7iPPQWt_5bocBPwzQ4EXrU_Khwy8xWIehq0ayCp8kD6nHm9D4imx66B1-hd6H1vXRl3jZDCEeg4vX6KKGJrmb3ztF2-XiLX8iq_Xjcz5fkZJr0xOXUa1UZm3lqFRQZpTpmcpKIbkFULWsQVhXWa2MdVCDMsZxpnlNNTNcajFF9PS3jCGl6OriPfoW4qFgtDiqKv6qGifkNEmwc8U-DHHUkP7v_wDMnmkb</recordid><startdate>20000601</startdate><enddate>20000601</enddate><creator>Kostov, Yordan</creator><creator>Van Houten, Kelly A.</creator><creator>Harms, Peter</creator><creator>Pilato, Robert S.</creator><creator>Rao, Govind</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20000601</creationdate><title>Unique Oxygen Analyzer Combining a Dual Emission Probe and a Low-Cost Solid-State Ratiometric Fluorometer</title><author>Kostov, Yordan ; Van Houten, Kelly A. ; Harms, Peter ; Pilato, Robert S. ; Rao, Govind</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c279t-e407664bbde056ac4017864c352baa6f5fa3bedb769beafa699e2172f07192573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kostov, Yordan</creatorcontrib><creatorcontrib>Van Houten, Kelly A.</creatorcontrib><creatorcontrib>Harms, Peter</creatorcontrib><creatorcontrib>Pilato, Robert S.</creatorcontrib><creatorcontrib>Rao, Govind</creatorcontrib><collection>CrossRef</collection><jtitle>Applied spectroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kostov, Yordan</au><au>Van Houten, Kelly A.</au><au>Harms, Peter</au><au>Pilato, Robert S.</au><au>Rao, Govind</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Unique Oxygen Analyzer Combining a Dual Emission Probe and a Low-Cost Solid-State Ratiometric Fluorometer</atitle><jtitle>Applied spectroscopy</jtitle><date>2000-06-01</date><risdate>2000</risdate><volume>54</volume><issue>6</issue><spage>864</spage><epage>868</epage><pages>864-868</pages><issn>0003-7028</issn><eissn>1943-3530</eissn><abstract>A new oxygen analyzer combining a polymer-encapsulated dual-emission probe and a diode-based ratiometric fluorometer is described. The ratiometric fluorometer was configured to measure the relative fluorescence and phosphorescence intensity of the short-lived singlet and long-lived oxygen-quenchable triplet of [(dppe)Pt{S2C2(CH2CH2–N–2-pyridinium)}](BPh4), where dppe is 1,2-bis(diphenylphosphino)ethane. This luminescent dye was immobilized at 0.3% by weight in cellulose acetate/75% triethylcitrate and cast into a 0.5 mm-thick film. The dye molecule was excited with a blue light-emitting diode (LED) and the singlet and triplet emissions monitored by individual photodiodes at 570 and 680 nm, respectively. Oxygen can be accurately measured without interference from nonanalyte-induced intensity changes by monitoring the relative output of the two photodiodes. The output of the device was linear with oxygen concentration. The PO2(1/2) from the ratio-adapted Stern–Volmer plot was 9.6% oxygen (≈73 torr), offering a dynamic range of 0–90% O2. The device is stable and the oxygen measurements reproducible. Intentional photobleaching of ≈20% of the sensor dye had little effect upon the reproducibility of the oxygen measurements.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1366/0003702001950238</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-7028 |
ispartof | Applied spectroscopy, 2000-06, Vol.54 (6), p.864-868 |
issn | 0003-7028 1943-3530 |
language | eng |
recordid | cdi_crossref_primary_10_1366_0003702001950238 |
source | SAGE Complete A-Z List |
title | Unique Oxygen Analyzer Combining a Dual Emission Probe and a Low-Cost Solid-State Ratiometric Fluorometer |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T19%3A24%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Unique%20Oxygen%20Analyzer%20Combining%20a%20Dual%20Emission%20Probe%20and%20a%20Low-Cost%20Solid-State%20Ratiometric%20Fluorometer&rft.jtitle=Applied%20spectroscopy&rft.au=Kostov,%20Yordan&rft.date=2000-06-01&rft.volume=54&rft.issue=6&rft.spage=864&rft.epage=868&rft.pages=864-868&rft.issn=0003-7028&rft.eissn=1943-3530&rft_id=info:doi/10.1366/0003702001950238&rft_dat=%3Csage_cross%3E10.1366_0003702001950238%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1366_0003702001950238&rfr_iscdi=true |