Study on Flow Near the Impeller Outlet of a Winnowing Fan : 3rd Report, Observations on the Static Pressure Contour Near to Impellers and the Particles Flow Near to Delivery and Suction Ports
This study aimed at clarifying unsteady flow near the delivery port of winnowing fans using CFD technology, the commercially available flow analysis software FLUENT/UNS, and the visualization software AVS. Both standard impellers and forward-inclined impellers were studied for comparison purposes. T...
Gespeichert in:
Veröffentlicht in: | Nihon Kikai Gakkai rombunshuu. B hen 2001/06/25, Vol.67(658), pp.1376-1383 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng ; jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1383 |
---|---|
container_issue | 658 |
container_start_page | 1376 |
container_title | Nihon Kikai Gakkai rombunshuu. B hen |
container_volume | 67 |
creator | KAWASE, Muneyuki FUKUTOMI, Junichiro NAKASE, Yoshiyuki |
description | This study aimed at clarifying unsteady flow near the delivery port of winnowing fans using CFD technology, the commercially available flow analysis software FLUENT/UNS, and the visualization software AVS. Both standard impellers and forward-inclined impellers were studied for comparison purposes. The results of this investigation demonstrate that forward-inclined impellers have better performance in terms of producing uniform flow. They develop many points where the static pressure is low, and from where large and unstable three-dimensional vortexes are produced. It was also demonstrated that a characteristic of winnowing fans is that they produce a balance between the swirling now after the suction port and that after the delivery port. This means that the flow after the impeller can be made uniform within a short distance. |
doi_str_mv | 10.1299/kikaib.67.1376 |
format | Article |
fullrecord | <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1299_kikaib_67_1376</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_kikaib1979_67_658_67_658_1376_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2046-fa5e8ed8c7c4f7e3787849dc7ec718144faead2301417c0b101d47a8c215805f3</originalsourceid><addsrcrecordid>eNpNkcFOwzAQRC0EEhX0ynk_gBS7dmKHGyoUEIhWFMQxcp0NBIJd2Q6oX8ev0bSl4rRaad7MroaQE0YHbJjnZx_1h67ng0wOGJfZHukxpUSiuMj2SY9yJZOUsuyQ9EOo55TSnGc5lz3yM4ttuQRnYdy4b3hA7SG-Idx-LrBp0MOkjQ1GcBVoeKmtdd-1fYWxtnAO3JfwiAvn4ylM5gH9l461s6Gz60xmcbUbmHoMofUII2eja_02xe1CAmhbromp9iuiwfD_HAeX2NRf6Jdr3aw1XQpMV7nhmBxUugnY384j8jy-ehrdJPeT69vRxX1ihlRkSaVTVFgqI42oJHKppBJ5aSQayRQTotKoyyGnTDBp6JxRVgqplRmyVNG04kdksPE13oXgsSoWvv7UflkwWnQNFJsGikwWXQMr4G4DvIeoX3En3z64lbNc5h2SpepvdPROZd60L9DyXz0Yl1o</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Study on Flow Near the Impeller Outlet of a Winnowing Fan : 3rd Report, Observations on the Static Pressure Contour Near to Impellers and the Particles Flow Near to Delivery and Suction Ports</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>KAWASE, Muneyuki ; FUKUTOMI, Junichiro ; NAKASE, Yoshiyuki</creator><creatorcontrib>KAWASE, Muneyuki ; FUKUTOMI, Junichiro ; NAKASE, Yoshiyuki</creatorcontrib><description>This study aimed at clarifying unsteady flow near the delivery port of winnowing fans using CFD technology, the commercially available flow analysis software FLUENT/UNS, and the visualization software AVS. Both standard impellers and forward-inclined impellers were studied for comparison purposes. The results of this investigation demonstrate that forward-inclined impellers have better performance in terms of producing uniform flow. They develop many points where the static pressure is low, and from where large and unstable three-dimensional vortexes are produced. It was also demonstrated that a characteristic of winnowing fans is that they produce a balance between the swirling now after the suction port and that after the delivery port. This means that the flow after the impeller can be made uniform within a short distance.</description><identifier>ISSN: 0387-5016</identifier><identifier>EISSN: 1884-8346</identifier><identifier>DOI: 10.1299/kikaib.67.1376</identifier><language>eng ; jpn</language><publisher>The Japan Society of Mechanical Engineers</publisher><subject>Winnowing Fan</subject><ispartof>Transactions of the Japan Society of Mechanical Engineers Series B, 2001/06/25, Vol.67(658), pp.1376-1383</ispartof><rights>The Japan Society of Mechanical Engineers</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1883,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>KAWASE, Muneyuki</creatorcontrib><creatorcontrib>FUKUTOMI, Junichiro</creatorcontrib><creatorcontrib>NAKASE, Yoshiyuki</creatorcontrib><title>Study on Flow Near the Impeller Outlet of a Winnowing Fan : 3rd Report, Observations on the Static Pressure Contour Near to Impellers and the Particles Flow Near to Delivery and Suction Ports</title><title>Nihon Kikai Gakkai rombunshuu. B hen</title><addtitle>JSMET</addtitle><description>This study aimed at clarifying unsteady flow near the delivery port of winnowing fans using CFD technology, the commercially available flow analysis software FLUENT/UNS, and the visualization software AVS. Both standard impellers and forward-inclined impellers were studied for comparison purposes. The results of this investigation demonstrate that forward-inclined impellers have better performance in terms of producing uniform flow. They develop many points where the static pressure is low, and from where large and unstable three-dimensional vortexes are produced. It was also demonstrated that a characteristic of winnowing fans is that they produce a balance between the swirling now after the suction port and that after the delivery port. This means that the flow after the impeller can be made uniform within a short distance.</description><subject>Winnowing Fan</subject><issn>0387-5016</issn><issn>1884-8346</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNpNkcFOwzAQRC0EEhX0ynk_gBS7dmKHGyoUEIhWFMQxcp0NBIJd2Q6oX8ev0bSl4rRaad7MroaQE0YHbJjnZx_1h67ng0wOGJfZHukxpUSiuMj2SY9yJZOUsuyQ9EOo55TSnGc5lz3yM4ttuQRnYdy4b3hA7SG-Idx-LrBp0MOkjQ1GcBVoeKmtdd-1fYWxtnAO3JfwiAvn4ylM5gH9l461s6Gz60xmcbUbmHoMofUII2eja_02xe1CAmhbromp9iuiwfD_HAeX2NRf6Jdr3aw1XQpMV7nhmBxUugnY384j8jy-ehrdJPeT69vRxX1ihlRkSaVTVFgqI42oJHKppBJ5aSQayRQTotKoyyGnTDBp6JxRVgqplRmyVNG04kdksPE13oXgsSoWvv7UflkwWnQNFJsGikwWXQMr4G4DvIeoX3En3z64lbNc5h2SpepvdPROZd60L9DyXz0Yl1o</recordid><startdate>2001</startdate><enddate>2001</enddate><creator>KAWASE, Muneyuki</creator><creator>FUKUTOMI, Junichiro</creator><creator>NAKASE, Yoshiyuki</creator><general>The Japan Society of Mechanical Engineers</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2001</creationdate><title>Study on Flow Near the Impeller Outlet of a Winnowing Fan : 3rd Report, Observations on the Static Pressure Contour Near to Impellers and the Particles Flow Near to Delivery and Suction Ports</title><author>KAWASE, Muneyuki ; FUKUTOMI, Junichiro ; NAKASE, Yoshiyuki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2046-fa5e8ed8c7c4f7e3787849dc7ec718144faead2301417c0b101d47a8c215805f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2001</creationdate><topic>Winnowing Fan</topic><toplevel>online_resources</toplevel><creatorcontrib>KAWASE, Muneyuki</creatorcontrib><creatorcontrib>FUKUTOMI, Junichiro</creatorcontrib><creatorcontrib>NAKASE, Yoshiyuki</creatorcontrib><collection>CrossRef</collection><jtitle>Nihon Kikai Gakkai rombunshuu. B hen</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KAWASE, Muneyuki</au><au>FUKUTOMI, Junichiro</au><au>NAKASE, Yoshiyuki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Study on Flow Near the Impeller Outlet of a Winnowing Fan : 3rd Report, Observations on the Static Pressure Contour Near to Impellers and the Particles Flow Near to Delivery and Suction Ports</atitle><jtitle>Nihon Kikai Gakkai rombunshuu. B hen</jtitle><addtitle>JSMET</addtitle><date>2001</date><risdate>2001</risdate><volume>67</volume><issue>658</issue><spage>1376</spage><epage>1383</epage><pages>1376-1383</pages><issn>0387-5016</issn><eissn>1884-8346</eissn><abstract>This study aimed at clarifying unsteady flow near the delivery port of winnowing fans using CFD technology, the commercially available flow analysis software FLUENT/UNS, and the visualization software AVS. Both standard impellers and forward-inclined impellers were studied for comparison purposes. The results of this investigation demonstrate that forward-inclined impellers have better performance in terms of producing uniform flow. They develop many points where the static pressure is low, and from where large and unstable three-dimensional vortexes are produced. It was also demonstrated that a characteristic of winnowing fans is that they produce a balance between the swirling now after the suction port and that after the delivery port. This means that the flow after the impeller can be made uniform within a short distance.</abstract><pub>The Japan Society of Mechanical Engineers</pub><doi>10.1299/kikaib.67.1376</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0387-5016 |
ispartof | Transactions of the Japan Society of Mechanical Engineers Series B, 2001/06/25, Vol.67(658), pp.1376-1383 |
issn | 0387-5016 1884-8346 |
language | eng ; jpn |
recordid | cdi_crossref_primary_10_1299_kikaib_67_1376 |
source | J-STAGE Free; EZB-FREE-00999 freely available EZB journals |
subjects | Winnowing Fan |
title | Study on Flow Near the Impeller Outlet of a Winnowing Fan : 3rd Report, Observations on the Static Pressure Contour Near to Impellers and the Particles Flow Near to Delivery and Suction Ports |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T21%3A21%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Study%20on%20Flow%20Near%20the%20Impeller%20Outlet%20of%20a%20Winnowing%20Fan%20:%203rd%20Report,%20Observations%20on%20the%20Static%20Pressure%20Contour%20Near%20to%20Impellers%20and%20the%20Particles%20Flow%20Near%20to%20Delivery%20and%20Suction%20Ports&rft.jtitle=Nihon%20Kikai%20Gakkai%20rombunshuu.%20B%20hen&rft.au=KAWASE,%20Muneyuki&rft.date=2001&rft.volume=67&rft.issue=658&rft.spage=1376&rft.epage=1383&rft.pages=1376-1383&rft.issn=0387-5016&rft.eissn=1884-8346&rft_id=info:doi/10.1299/kikaib.67.1376&rft_dat=%3Cjstage_cross%3Earticle_kikaib1979_67_658_67_658_1376_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |