Augmentation Mechanism of Forced-Convection Heat Transfer by Applying Electric Fields in the Restricted Region near the Wall

By applying electric fields using the array of wire electrodes installed near the heat transfer wall along the main stream, in the range of low Reynolds number, the heat transfer coefficients of liquid were augmented to the same order as that in turbulent flow, and the pressure drop was increased bu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nihon Kikai Gakkai rombunshuu. B hen 1995/05/25, Vol.61(585), pp.1775-1781
Hauptverfasser: Yabe, Akira, Adachi, Masaki, Katayama, Ryu, Nariai, Hideki
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1781
container_issue 585
container_start_page 1775
container_title Nihon Kikai Gakkai rombunshuu. B hen
container_volume 61
creator Yabe, Akira
Adachi, Masaki
Katayama, Ryu
Nariai, Hideki
description By applying electric fields using the array of wire electrodes installed near the heat transfer wall along the main stream, in the range of low Reynolds number, the heat transfer coefficients of liquid were augmented to the same order as that in turbulent flow, and the pressure drop was increased but still remained on the same order as that in laminar flow. It was clarified that the ratio of Colburn's J factor to the friction factor for evaluating the performance became 4.4 times for Re = 1470 and 1.9 times for Re = 20000 with the electric field of 10 kV/cm. Furthermore, by analyzing the power spectrum of the flow velocity and electric current, the peak regions around 1 Hz were found to be increased by applying electric fields, which means the fluctuation of negative ion flow emitted from the cathode, as clarified by the voltage-current characteristics of the electrostatic probe in the higher-potential region.
doi_str_mv 10.1299/kikaib.61.1775
format Article
fullrecord <record><control><sourceid>jstage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1299_kikaib_61_1775</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>article_kikaib1979_61_585_61_585_1775_article_char_en</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3175-73f35a48cae1216f0130ecd7c6cf4540d9e220eeca3ed9f8086eec8f9669e9743</originalsourceid><addsrcrecordid>eNo9kF1PwjAYhRujiQS59bp_YLNdt35cEgJixJgYjJdL6d6OyuhIO01I_PFuoFy9H-c55-IgdE9JSjOlHnZup90m5TSlQhRXaESlzBPJcn6NRoRJkRSE8ls0idFtCCGKccXECP1Mv-o9-E53rvX4BcxWexf3uLV40QYDVTJr_TeYk7wE3eF10D5aCHhzxNPDoTk6X-N50yPBGbxw0FQRO4-7LeA3iMO3g6pf6yHCgw4n6UM3zR26sbqJMPmbY_S-mK9ny2T1-vg0m64Sw6goEsEsK3QujQaaUW4JZQRMJQw3Ni9yUinIMgJgNINKWUkk7w9pFecKlMjZGKXnXBPaGAPY8hDcXodjSUk51Fee6ys5LYf6esPz2fAZO13DBdehc6aBP5wqoQZLIYv_MbgvVN9lKMGzX1vRgG0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Augmentation Mechanism of Forced-Convection Heat Transfer by Applying Electric Fields in the Restricted Region near the Wall</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Yabe, Akira ; Adachi, Masaki ; Katayama, Ryu ; Nariai, Hideki</creator><creatorcontrib>Yabe, Akira ; Adachi, Masaki ; Katayama, Ryu ; Nariai, Hideki</creatorcontrib><description>By applying electric fields using the array of wire electrodes installed near the heat transfer wall along the main stream, in the range of low Reynolds number, the heat transfer coefficients of liquid were augmented to the same order as that in turbulent flow, and the pressure drop was increased but still remained on the same order as that in laminar flow. It was clarified that the ratio of Colburn's J factor to the friction factor for evaluating the performance became 4.4 times for Re = 1470 and 1.9 times for Re = 20000 with the electric field of 10 kV/cm. Furthermore, by analyzing the power spectrum of the flow velocity and electric current, the peak regions around 1 Hz were found to be increased by applying electric fields, which means the fluctuation of negative ion flow emitted from the cathode, as clarified by the voltage-current characteristics of the electrostatic probe in the higher-potential region.</description><identifier>ISSN: 0387-5016</identifier><identifier>EISSN: 1884-8346</identifier><identifier>DOI: 10.1299/kikaib.61.1775</identifier><language>eng ; jpn</language><publisher>The Japan Society of Mechanical Engineers</publisher><subject>Forced-Convection of Liquid</subject><ispartof>Transactions of the Japan Society of Mechanical Engineers Series B, 1995/05/25, Vol.61(585), pp.1775-1781</ispartof><rights>The Japan Society of Mechanical Engineers</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3175-73f35a48cae1216f0130ecd7c6cf4540d9e220eeca3ed9f8086eec8f9669e9743</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,1877,4010,27904,27905,27906</link.rule.ids></links><search><creatorcontrib>Yabe, Akira</creatorcontrib><creatorcontrib>Adachi, Masaki</creatorcontrib><creatorcontrib>Katayama, Ryu</creatorcontrib><creatorcontrib>Nariai, Hideki</creatorcontrib><title>Augmentation Mechanism of Forced-Convection Heat Transfer by Applying Electric Fields in the Restricted Region near the Wall</title><title>Nihon Kikai Gakkai rombunshuu. B hen</title><addtitle>JSMET</addtitle><description>By applying electric fields using the array of wire electrodes installed near the heat transfer wall along the main stream, in the range of low Reynolds number, the heat transfer coefficients of liquid were augmented to the same order as that in turbulent flow, and the pressure drop was increased but still remained on the same order as that in laminar flow. It was clarified that the ratio of Colburn's J factor to the friction factor for evaluating the performance became 4.4 times for Re = 1470 and 1.9 times for Re = 20000 with the electric field of 10 kV/cm. Furthermore, by analyzing the power spectrum of the flow velocity and electric current, the peak regions around 1 Hz were found to be increased by applying electric fields, which means the fluctuation of negative ion flow emitted from the cathode, as clarified by the voltage-current characteristics of the electrostatic probe in the higher-potential region.</description><subject>Forced-Convection of Liquid</subject><issn>0387-5016</issn><issn>1884-8346</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNo9kF1PwjAYhRujiQS59bp_YLNdt35cEgJixJgYjJdL6d6OyuhIO01I_PFuoFy9H-c55-IgdE9JSjOlHnZup90m5TSlQhRXaESlzBPJcn6NRoRJkRSE8ls0idFtCCGKccXECP1Mv-o9-E53rvX4BcxWexf3uLV40QYDVTJr_TeYk7wE3eF10D5aCHhzxNPDoTk6X-N50yPBGbxw0FQRO4-7LeA3iMO3g6pf6yHCgw4n6UM3zR26sbqJMPmbY_S-mK9ny2T1-vg0m64Sw6goEsEsK3QujQaaUW4JZQRMJQw3Ni9yUinIMgJgNINKWUkk7w9pFecKlMjZGKXnXBPaGAPY8hDcXodjSUk51Fee6ys5LYf6esPz2fAZO13DBdehc6aBP5wqoQZLIYv_MbgvVN9lKMGzX1vRgG0</recordid><startdate>1995</startdate><enddate>1995</enddate><creator>Yabe, Akira</creator><creator>Adachi, Masaki</creator><creator>Katayama, Ryu</creator><creator>Nariai, Hideki</creator><general>The Japan Society of Mechanical Engineers</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1995</creationdate><title>Augmentation Mechanism of Forced-Convection Heat Transfer by Applying Electric Fields in the Restricted Region near the Wall</title><author>Yabe, Akira ; Adachi, Masaki ; Katayama, Ryu ; Nariai, Hideki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3175-73f35a48cae1216f0130ecd7c6cf4540d9e220eeca3ed9f8086eec8f9669e9743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>1995</creationdate><topic>Forced-Convection of Liquid</topic><toplevel>online_resources</toplevel><creatorcontrib>Yabe, Akira</creatorcontrib><creatorcontrib>Adachi, Masaki</creatorcontrib><creatorcontrib>Katayama, Ryu</creatorcontrib><creatorcontrib>Nariai, Hideki</creatorcontrib><collection>CrossRef</collection><jtitle>Nihon Kikai Gakkai rombunshuu. B hen</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yabe, Akira</au><au>Adachi, Masaki</au><au>Katayama, Ryu</au><au>Nariai, Hideki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Augmentation Mechanism of Forced-Convection Heat Transfer by Applying Electric Fields in the Restricted Region near the Wall</atitle><jtitle>Nihon Kikai Gakkai rombunshuu. B hen</jtitle><addtitle>JSMET</addtitle><date>1995</date><risdate>1995</risdate><volume>61</volume><issue>585</issue><spage>1775</spage><epage>1781</epage><pages>1775-1781</pages><issn>0387-5016</issn><eissn>1884-8346</eissn><abstract>By applying electric fields using the array of wire electrodes installed near the heat transfer wall along the main stream, in the range of low Reynolds number, the heat transfer coefficients of liquid were augmented to the same order as that in turbulent flow, and the pressure drop was increased but still remained on the same order as that in laminar flow. It was clarified that the ratio of Colburn's J factor to the friction factor for evaluating the performance became 4.4 times for Re = 1470 and 1.9 times for Re = 20000 with the electric field of 10 kV/cm. Furthermore, by analyzing the power spectrum of the flow velocity and electric current, the peak regions around 1 Hz were found to be increased by applying electric fields, which means the fluctuation of negative ion flow emitted from the cathode, as clarified by the voltage-current characteristics of the electrostatic probe in the higher-potential region.</abstract><pub>The Japan Society of Mechanical Engineers</pub><doi>10.1299/kikaib.61.1775</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0387-5016
ispartof Transactions of the Japan Society of Mechanical Engineers Series B, 1995/05/25, Vol.61(585), pp.1775-1781
issn 0387-5016
1884-8346
language eng ; jpn
recordid cdi_crossref_primary_10_1299_kikaib_61_1775
source J-STAGE Free; EZB-FREE-00999 freely available EZB journals
subjects Forced-Convection of Liquid
title Augmentation Mechanism of Forced-Convection Heat Transfer by Applying Electric Fields in the Restricted Region near the Wall
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T07%3A14%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Augmentation%20Mechanism%20of%20Forced-Convection%20Heat%20Transfer%20by%20Applying%20Electric%20Fields%20in%20the%20Restricted%20Region%20near%20the%20Wall&rft.jtitle=Nihon%20Kikai%20Gakkai%20rombunshuu.%20B%20hen&rft.au=Yabe,%20Akira&rft.date=1995&rft.volume=61&rft.issue=585&rft.spage=1775&rft.epage=1781&rft.pages=1775-1781&rft.issn=0387-5016&rft.eissn=1884-8346&rft_id=info:doi/10.1299/kikaib.61.1775&rft_dat=%3Cjstage_cross%3Earticle_kikaib1979_61_585_61_585_1775_article_char_en%3C/jstage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true