Study on Mode III Fracture Toughness Testing Method Using Uniaxial Testing Machine
The mode III fracture toughness testing method using single axis testing machine is developed.Four point shear specimen is used with small amount of mode I loading to avoid the contact of crack surfaces.The shape of the specimen, and the amount of mode I loading are determined based on the three dim...
Gespeichert in:
Veröffentlicht in: | TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A 2000/01/25, Vol.66(641), pp.131-136 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng ; jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The mode III fracture toughness testing method using single axis testing machine is developed.Four point shear specimen is used with small amount of mode I loading to avoid the contact of crack surfaces.The shape of the specimen, and the amount of mode I loading are determined based on the three dimensional FEM analysis.The crack tip stress field is also obtained, and compared with the HRR(Hutchinson-Rice-Rosengren)singularity.The conventional equation to evaluate the J-integral by the load-displacement record is proposed and the accuracy of this equation is verified.Finally the mode III fracture toughness, J IIIC, of aluminum alloy and A 533 B steel are obtained. |
---|---|
ISSN: | 0387-5008 1884-8338 |
DOI: | 10.1299/kikaia.66.131 |