Estimation of organ and effective doses resulting from cone beam CT imaging for radiotherapy treatment planning

In this study, organ doses were measured for various kilovoltage cone beam CT exposures on the Varian Acuity simulator and an alternative method of dose estimation was also assessed. Organ doses were measured by distributing thermoluminescent dosimeters (TLDs) throughout an anthropomorphic phantom,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of radiology 2009-07, Vol.82 (979), p.577-584
Hauptverfasser: SAWYER, L. J, WHITTLE, S. A, MATTHEWS, E. S, STARRITT, H. C, JUPP, T. P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 584
container_issue 979
container_start_page 577
container_title British journal of radiology
container_volume 82
creator SAWYER, L. J
WHITTLE, S. A
MATTHEWS, E. S
STARRITT, H. C
JUPP, T. P
description In this study, organ doses were measured for various kilovoltage cone beam CT exposures on the Varian Acuity simulator and an alternative method of dose estimation was also assessed. Organ doses were measured by distributing thermoluminescent dosimeters (TLDs) throughout an anthropomorphic phantom, and effective doses were calculated using International Commission on Radiological Protection (ICRP) 60 and ICRP 103 tissue-weighting factors. The ImPACT CT patient dosimetry calculator was also used to estimate doses for comparison with the TLD results. Effective doses of 15.3 mSv (19.4 mSv), 14.3 mSv (9.7 mSv) and 2.8 mSv (3.2 mSv) were calculated from the TLD measurements and ICRP 60 (ICRP 103) weighting factors for breast, pelvis and head acquisitions, respectively. When a 10 cm pencil ionisation chamber was used to measure the CT dose index, the ImPACT calculator was found to provide an adequate estimation of dose when compared with the TLD results. However, the doses for half-fan exposures were found to be overestimated, with the extent of overestimation depending on the radiosensitive organs irradiated. The organ and effective doses reported provide information for justification and optimisation of cone beam CT procedures, and are compared with doses delivered by other imaging devices. The ImPACT calculator may be used to estimate doses from cone beam CT procedures, if the potential for overestimation is acknowledged.
doi_str_mv 10.1259/bjr/62467578
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1259_bjr_62467578</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>19255115</sourcerecordid><originalsourceid>FETCH-LOGICAL-c319t-d25e8a643172e18944916d919da0f1b43e6e33c431c5dfefb565f2820fa396943</originalsourceid><addsrcrecordid>eNpFkEtLw0AUhQdRbK3uXMts3Bk772SWUuoDCm4quAuT5E5NSWbCzFTw35vaqqvL4XwcLh9C15TcUyb1vNqGuWJC5TIvTtCU5qLIioK8n6IpISTPKCvkBF3EuN1Hqck5mlDNpKRUTpFfxtT2JrXeYW-xDxvjsHENBmuhTu0n4MZHiDhA3HWpdRtsg-9x7R3gCkyPF2s8Dmx-Gh9wME3r0wcEM3zhFMCkHlzCQ2ecG5lLdGZNF-HqeGfo7XG5Xjxnq9enl8XDKqs51SlrmITCKMFpzoAWWghNVaOpbgyxtBIcFHBej30tGwu2kkpaVjBiDddKCz5Dd4fdOvgYA9hyCOOb4aukpNx7K0dv5a-3Eb854MOu6qH5h4-iRuD2CJhYm84G4-o2_nGMKqWlkPwbB7V3Qw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Estimation of organ and effective doses resulting from cone beam CT imaging for radiotherapy treatment planning</title><source>MEDLINE</source><source>Oxford University Press Journals All Titles (1996-Current)</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>SAWYER, L. J ; WHITTLE, S. A ; MATTHEWS, E. S ; STARRITT, H. C ; JUPP, T. P</creator><creatorcontrib>SAWYER, L. J ; WHITTLE, S. A ; MATTHEWS, E. S ; STARRITT, H. C ; JUPP, T. P</creatorcontrib><description>In this study, organ doses were measured for various kilovoltage cone beam CT exposures on the Varian Acuity simulator and an alternative method of dose estimation was also assessed. Organ doses were measured by distributing thermoluminescent dosimeters (TLDs) throughout an anthropomorphic phantom, and effective doses were calculated using International Commission on Radiological Protection (ICRP) 60 and ICRP 103 tissue-weighting factors. The ImPACT CT patient dosimetry calculator was also used to estimate doses for comparison with the TLD results. Effective doses of 15.3 mSv (19.4 mSv), 14.3 mSv (9.7 mSv) and 2.8 mSv (3.2 mSv) were calculated from the TLD measurements and ICRP 60 (ICRP 103) weighting factors for breast, pelvis and head acquisitions, respectively. When a 10 cm pencil ionisation chamber was used to measure the CT dose index, the ImPACT calculator was found to provide an adequate estimation of dose when compared with the TLD results. However, the doses for half-fan exposures were found to be overestimated, with the extent of overestimation depending on the radiosensitive organs irradiated. The organ and effective doses reported provide information for justification and optimisation of cone beam CT procedures, and are compared with doses delivered by other imaging devices. The ImPACT calculator may be used to estimate doses from cone beam CT procedures, if the potential for overestimation is acknowledged.</description><identifier>ISSN: 0007-1285</identifier><identifier>EISSN: 1748-880X</identifier><identifier>DOI: 10.1259/bjr/62467578</identifier><identifier>PMID: 19255115</identifier><identifier>CODEN: BJRAAP</identifier><language>eng</language><publisher>London: British Institute of Radiology</publisher><subject>Biological and medical sciences ; Cone-Beam Computed Tomography - standards ; Fluorides - radiation effects ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Lithium Compounds - radiation effects ; Medical sciences ; Phantoms, Imaging ; Radiation Dosage ; Radiopharmaceuticals - radiation effects ; Radiotherapy Dosage ; Reference Values ; Sensitivity and Specificity</subject><ispartof>British journal of radiology, 2009-07, Vol.82 (979), p.577-584</ispartof><rights>2009 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c319t-d25e8a643172e18944916d919da0f1b43e6e33c431c5dfefb565f2820fa396943</citedby><cites>FETCH-LOGICAL-c319t-d25e8a643172e18944916d919da0f1b43e6e33c431c5dfefb565f2820fa396943</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=21669545$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19255115$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>SAWYER, L. J</creatorcontrib><creatorcontrib>WHITTLE, S. A</creatorcontrib><creatorcontrib>MATTHEWS, E. S</creatorcontrib><creatorcontrib>STARRITT, H. C</creatorcontrib><creatorcontrib>JUPP, T. P</creatorcontrib><title>Estimation of organ and effective doses resulting from cone beam CT imaging for radiotherapy treatment planning</title><title>British journal of radiology</title><addtitle>Br J Radiol</addtitle><description>In this study, organ doses were measured for various kilovoltage cone beam CT exposures on the Varian Acuity simulator and an alternative method of dose estimation was also assessed. Organ doses were measured by distributing thermoluminescent dosimeters (TLDs) throughout an anthropomorphic phantom, and effective doses were calculated using International Commission on Radiological Protection (ICRP) 60 and ICRP 103 tissue-weighting factors. The ImPACT CT patient dosimetry calculator was also used to estimate doses for comparison with the TLD results. Effective doses of 15.3 mSv (19.4 mSv), 14.3 mSv (9.7 mSv) and 2.8 mSv (3.2 mSv) were calculated from the TLD measurements and ICRP 60 (ICRP 103) weighting factors for breast, pelvis and head acquisitions, respectively. When a 10 cm pencil ionisation chamber was used to measure the CT dose index, the ImPACT calculator was found to provide an adequate estimation of dose when compared with the TLD results. However, the doses for half-fan exposures were found to be overestimated, with the extent of overestimation depending on the radiosensitive organs irradiated. The organ and effective doses reported provide information for justification and optimisation of cone beam CT procedures, and are compared with doses delivered by other imaging devices. The ImPACT calculator may be used to estimate doses from cone beam CT procedures, if the potential for overestimation is acknowledged.</description><subject>Biological and medical sciences</subject><subject>Cone-Beam Computed Tomography - standards</subject><subject>Fluorides - radiation effects</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Lithium Compounds - radiation effects</subject><subject>Medical sciences</subject><subject>Phantoms, Imaging</subject><subject>Radiation Dosage</subject><subject>Radiopharmaceuticals - radiation effects</subject><subject>Radiotherapy Dosage</subject><subject>Reference Values</subject><subject>Sensitivity and Specificity</subject><issn>0007-1285</issn><issn>1748-880X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkEtLw0AUhQdRbK3uXMts3Bk772SWUuoDCm4quAuT5E5NSWbCzFTw35vaqqvL4XwcLh9C15TcUyb1vNqGuWJC5TIvTtCU5qLIioK8n6IpISTPKCvkBF3EuN1Hqck5mlDNpKRUTpFfxtT2JrXeYW-xDxvjsHENBmuhTu0n4MZHiDhA3HWpdRtsg-9x7R3gCkyPF2s8Dmx-Gh9wME3r0wcEM3zhFMCkHlzCQ2ecG5lLdGZNF-HqeGfo7XG5Xjxnq9enl8XDKqs51SlrmITCKMFpzoAWWghNVaOpbgyxtBIcFHBej30tGwu2kkpaVjBiDddKCz5Dd4fdOvgYA9hyCOOb4aukpNx7K0dv5a-3Eb854MOu6qH5h4-iRuD2CJhYm84G4-o2_nGMKqWlkPwbB7V3Qw</recordid><startdate>20090701</startdate><enddate>20090701</enddate><creator>SAWYER, L. J</creator><creator>WHITTLE, S. A</creator><creator>MATTHEWS, E. S</creator><creator>STARRITT, H. C</creator><creator>JUPP, T. P</creator><general>British Institute of Radiology</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20090701</creationdate><title>Estimation of organ and effective doses resulting from cone beam CT imaging for radiotherapy treatment planning</title><author>SAWYER, L. J ; WHITTLE, S. A ; MATTHEWS, E. S ; STARRITT, H. C ; JUPP, T. P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c319t-d25e8a643172e18944916d919da0f1b43e6e33c431c5dfefb565f2820fa396943</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Biological and medical sciences</topic><topic>Cone-Beam Computed Tomography - standards</topic><topic>Fluorides - radiation effects</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Lithium Compounds - radiation effects</topic><topic>Medical sciences</topic><topic>Phantoms, Imaging</topic><topic>Radiation Dosage</topic><topic>Radiopharmaceuticals - radiation effects</topic><topic>Radiotherapy Dosage</topic><topic>Reference Values</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>SAWYER, L. J</creatorcontrib><creatorcontrib>WHITTLE, S. A</creatorcontrib><creatorcontrib>MATTHEWS, E. S</creatorcontrib><creatorcontrib>STARRITT, H. C</creatorcontrib><creatorcontrib>JUPP, T. P</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>British journal of radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SAWYER, L. J</au><au>WHITTLE, S. A</au><au>MATTHEWS, E. S</au><au>STARRITT, H. C</au><au>JUPP, T. P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Estimation of organ and effective doses resulting from cone beam CT imaging for radiotherapy treatment planning</atitle><jtitle>British journal of radiology</jtitle><addtitle>Br J Radiol</addtitle><date>2009-07-01</date><risdate>2009</risdate><volume>82</volume><issue>979</issue><spage>577</spage><epage>584</epage><pages>577-584</pages><issn>0007-1285</issn><eissn>1748-880X</eissn><coden>BJRAAP</coden><abstract>In this study, organ doses were measured for various kilovoltage cone beam CT exposures on the Varian Acuity simulator and an alternative method of dose estimation was also assessed. Organ doses were measured by distributing thermoluminescent dosimeters (TLDs) throughout an anthropomorphic phantom, and effective doses were calculated using International Commission on Radiological Protection (ICRP) 60 and ICRP 103 tissue-weighting factors. The ImPACT CT patient dosimetry calculator was also used to estimate doses for comparison with the TLD results. Effective doses of 15.3 mSv (19.4 mSv), 14.3 mSv (9.7 mSv) and 2.8 mSv (3.2 mSv) were calculated from the TLD measurements and ICRP 60 (ICRP 103) weighting factors for breast, pelvis and head acquisitions, respectively. When a 10 cm pencil ionisation chamber was used to measure the CT dose index, the ImPACT calculator was found to provide an adequate estimation of dose when compared with the TLD results. However, the doses for half-fan exposures were found to be overestimated, with the extent of overestimation depending on the radiosensitive organs irradiated. The organ and effective doses reported provide information for justification and optimisation of cone beam CT procedures, and are compared with doses delivered by other imaging devices. The ImPACT calculator may be used to estimate doses from cone beam CT procedures, if the potential for overestimation is acknowledged.</abstract><cop>London</cop><pub>British Institute of Radiology</pub><pmid>19255115</pmid><doi>10.1259/bjr/62467578</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0007-1285
ispartof British journal of radiology, 2009-07, Vol.82 (979), p.577-584
issn 0007-1285
1748-880X
language eng
recordid cdi_crossref_primary_10_1259_bjr_62467578
source MEDLINE; Oxford University Press Journals All Titles (1996-Current); EZB-FREE-00999 freely available EZB journals
subjects Biological and medical sciences
Cone-Beam Computed Tomography - standards
Fluorides - radiation effects
Humans
Investigative techniques, diagnostic techniques (general aspects)
Lithium Compounds - radiation effects
Medical sciences
Phantoms, Imaging
Radiation Dosage
Radiopharmaceuticals - radiation effects
Radiotherapy Dosage
Reference Values
Sensitivity and Specificity
title Estimation of organ and effective doses resulting from cone beam CT imaging for radiotherapy treatment planning
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T23%3A52%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Estimation%20of%20organ%20and%20effective%20doses%20resulting%20from%20cone%20beam%20CT%20imaging%20for%20radiotherapy%20treatment%20planning&rft.jtitle=British%20journal%20of%20radiology&rft.au=SAWYER,%20L.%20J&rft.date=2009-07-01&rft.volume=82&rft.issue=979&rft.spage=577&rft.epage=584&rft.pages=577-584&rft.issn=0007-1285&rft.eissn=1748-880X&rft.coden=BJRAAP&rft_id=info:doi/10.1259/bjr/62467578&rft_dat=%3Cpubmed_cross%3E19255115%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/19255115&rfr_iscdi=true