Flow-based Biosensing System for Glucose Fabricated by Using Track-etched Microporous Membrane Electrodes
The new type of amperometric biosensor described herein, which was fabricated by using a track-etched microporous membrane electrode for glucose detection, comprises a prereactor electrode, a detector electrode, and an immobilized enzyme reactor sandwiched between these electrodes. Because the sampl...
Gespeichert in:
Veröffentlicht in: | Chemistry letters 2013-10, Vol.42 (10), p.1317-1319 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1319 |
---|---|
container_issue | 10 |
container_start_page | 1317 |
container_title | Chemistry letters |
container_volume | 42 |
creator | Mizuguchi, Hitoshi Sakurai, Jun Kinoshita, Yuki Iiyama, Masamitsu Kijima, Tatsuro Tachibana, Kazuhiro Nishina, Tatsuo Shida, Junichi |
description | The new type of amperometric biosensor described herein, which was fabricated by using a track-etched microporous membrane electrode for glucose detection, comprises a prereactor electrode, a detector electrode, and an immobilized enzyme reactor sandwiched between these electrodes. Because the sample solution flows through this system, the interferents are electrolyzed completely at the prereactor, positioned upstream of the enzyme reactor. The increased current response at the detector electrode derives solely from oxidation of hydrogen peroxide produced in the enzymatic reaction. Sensitive and selective response toward glucose detection was obtained with no other catalytic material such as peroxidase or an electron mediator. |
doi_str_mv | 10.1246/cl.130594 |
format | Article |
fullrecord | <record><control><sourceid>chemicalsocietyjapan_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1246_cl_130594</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1246_cl_130594</sourcerecordid><originalsourceid>FETCH-LOGICAL-c386t-bc03759c61ea6b2cad7f82140c12c906af00368c7c632198f6d1375aaa3d1df03</originalsourceid><addsrcrecordid>eNptkM1OwzAQhC0EEqVw4A185eDin9RJjlC1BakVB9pztNk4NMWJKzsVytvX0B45rTT6ZrQzhDwKPhEy0c9oJ0LxaZ5ckZFQScZ4KqbXZMSV1izlUt6SuxD2nPMsV3JEmoV1P6yEYCr62rhgutB0X_RzCL1pae08XdojRp0uoPQNQh_BcqDbP2zjAb-Z6XEX1XWD3h2cd8dA16YtPXSGzq3B3rvKhHtyU4MN5uFyx2S7mG9mb2z1sXyfvawYqkz3rESu0mmOWhjQpUSo0jqTIuEoJOZcQ81jlwxT1EqKPKt1JaIBAFQlqpqrMXk658ZvQvCmLg6-acEPheDF70YF2uK8UWT1hd2ZNpazwWFj-mEPB-iKvTv6Lmr_GE87aG2G</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Flow-based Biosensing System for Glucose Fabricated by Using Track-etched Microporous Membrane Electrodes</title><source>Oxford Journals</source><creator>Mizuguchi, Hitoshi ; Sakurai, Jun ; Kinoshita, Yuki ; Iiyama, Masamitsu ; Kijima, Tatsuro ; Tachibana, Kazuhiro ; Nishina, Tatsuo ; Shida, Junichi</creator><creatorcontrib>Mizuguchi, Hitoshi ; Sakurai, Jun ; Kinoshita, Yuki ; Iiyama, Masamitsu ; Kijima, Tatsuro ; Tachibana, Kazuhiro ; Nishina, Tatsuo ; Shida, Junichi</creatorcontrib><description>The new type of amperometric biosensor described herein, which was fabricated by using a track-etched microporous membrane electrode for glucose detection, comprises a prereactor electrode, a detector electrode, and an immobilized enzyme reactor sandwiched between these electrodes. Because the sample solution flows through this system, the interferents are electrolyzed completely at the prereactor, positioned upstream of the enzyme reactor. The increased current response at the detector electrode derives solely from oxidation of hydrogen peroxide produced in the enzymatic reaction. Sensitive and selective response toward glucose detection was obtained with no other catalytic material such as peroxidase or an electron mediator.</description><identifier>ISSN: 0366-7022</identifier><identifier>EISSN: 1348-0715</identifier><identifier>DOI: 10.1246/cl.130594</identifier><language>eng</language><publisher>The Chemical Society of Japan</publisher><ispartof>Chemistry letters, 2013-10, Vol.42 (10), p.1317-1319</ispartof><rights>The Chemical Society of Japan</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c386t-bc03759c61ea6b2cad7f82140c12c906af00368c7c632198f6d1375aaa3d1df03</citedby><cites>FETCH-LOGICAL-c386t-bc03759c61ea6b2cad7f82140c12c906af00368c7c632198f6d1375aaa3d1df03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Mizuguchi, Hitoshi</creatorcontrib><creatorcontrib>Sakurai, Jun</creatorcontrib><creatorcontrib>Kinoshita, Yuki</creatorcontrib><creatorcontrib>Iiyama, Masamitsu</creatorcontrib><creatorcontrib>Kijima, Tatsuro</creatorcontrib><creatorcontrib>Tachibana, Kazuhiro</creatorcontrib><creatorcontrib>Nishina, Tatsuo</creatorcontrib><creatorcontrib>Shida, Junichi</creatorcontrib><title>Flow-based Biosensing System for Glucose Fabricated by Using Track-etched Microporous Membrane Electrodes</title><title>Chemistry letters</title><addtitle>Chemistry Letters</addtitle><description>The new type of amperometric biosensor described herein, which was fabricated by using a track-etched microporous membrane electrode for glucose detection, comprises a prereactor electrode, a detector electrode, and an immobilized enzyme reactor sandwiched between these electrodes. Because the sample solution flows through this system, the interferents are electrolyzed completely at the prereactor, positioned upstream of the enzyme reactor. The increased current response at the detector electrode derives solely from oxidation of hydrogen peroxide produced in the enzymatic reaction. Sensitive and selective response toward glucose detection was obtained with no other catalytic material such as peroxidase or an electron mediator.</description><issn>0366-7022</issn><issn>1348-0715</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNptkM1OwzAQhC0EEqVw4A185eDin9RJjlC1BakVB9pztNk4NMWJKzsVytvX0B45rTT6ZrQzhDwKPhEy0c9oJ0LxaZ5ckZFQScZ4KqbXZMSV1izlUt6SuxD2nPMsV3JEmoV1P6yEYCr62rhgutB0X_RzCL1pae08XdojRp0uoPQNQh_BcqDbP2zjAb-Z6XEX1XWD3h2cd8dA16YtPXSGzq3B3rvKhHtyU4MN5uFyx2S7mG9mb2z1sXyfvawYqkz3rESu0mmOWhjQpUSo0jqTIuEoJOZcQ81jlwxT1EqKPKt1JaIBAFQlqpqrMXk658ZvQvCmLg6-acEPheDF70YF2uK8UWT1hd2ZNpazwWFj-mEPB-iKvTv6Lmr_GE87aG2G</recordid><startdate>20131005</startdate><enddate>20131005</enddate><creator>Mizuguchi, Hitoshi</creator><creator>Sakurai, Jun</creator><creator>Kinoshita, Yuki</creator><creator>Iiyama, Masamitsu</creator><creator>Kijima, Tatsuro</creator><creator>Tachibana, Kazuhiro</creator><creator>Nishina, Tatsuo</creator><creator>Shida, Junichi</creator><general>The Chemical Society of Japan</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20131005</creationdate><title>Flow-based Biosensing System for Glucose Fabricated by Using Track-etched Microporous Membrane Electrodes</title><author>Mizuguchi, Hitoshi ; Sakurai, Jun ; Kinoshita, Yuki ; Iiyama, Masamitsu ; Kijima, Tatsuro ; Tachibana, Kazuhiro ; Nishina, Tatsuo ; Shida, Junichi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c386t-bc03759c61ea6b2cad7f82140c12c906af00368c7c632198f6d1375aaa3d1df03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mizuguchi, Hitoshi</creatorcontrib><creatorcontrib>Sakurai, Jun</creatorcontrib><creatorcontrib>Kinoshita, Yuki</creatorcontrib><creatorcontrib>Iiyama, Masamitsu</creatorcontrib><creatorcontrib>Kijima, Tatsuro</creatorcontrib><creatorcontrib>Tachibana, Kazuhiro</creatorcontrib><creatorcontrib>Nishina, Tatsuo</creatorcontrib><creatorcontrib>Shida, Junichi</creatorcontrib><collection>CrossRef</collection><jtitle>Chemistry letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mizuguchi, Hitoshi</au><au>Sakurai, Jun</au><au>Kinoshita, Yuki</au><au>Iiyama, Masamitsu</au><au>Kijima, Tatsuro</au><au>Tachibana, Kazuhiro</au><au>Nishina, Tatsuo</au><au>Shida, Junichi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Flow-based Biosensing System for Glucose Fabricated by Using Track-etched Microporous Membrane Electrodes</atitle><jtitle>Chemistry letters</jtitle><addtitle>Chemistry Letters</addtitle><date>2013-10-05</date><risdate>2013</risdate><volume>42</volume><issue>10</issue><spage>1317</spage><epage>1319</epage><pages>1317-1319</pages><issn>0366-7022</issn><eissn>1348-0715</eissn><abstract>The new type of amperometric biosensor described herein, which was fabricated by using a track-etched microporous membrane electrode for glucose detection, comprises a prereactor electrode, a detector electrode, and an immobilized enzyme reactor sandwiched between these electrodes. Because the sample solution flows through this system, the interferents are electrolyzed completely at the prereactor, positioned upstream of the enzyme reactor. The increased current response at the detector electrode derives solely from oxidation of hydrogen peroxide produced in the enzymatic reaction. Sensitive and selective response toward glucose detection was obtained with no other catalytic material such as peroxidase or an electron mediator.</abstract><pub>The Chemical Society of Japan</pub><doi>10.1246/cl.130594</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0366-7022 |
ispartof | Chemistry letters, 2013-10, Vol.42 (10), p.1317-1319 |
issn | 0366-7022 1348-0715 |
language | eng |
recordid | cdi_crossref_primary_10_1246_cl_130594 |
source | Oxford Journals |
title | Flow-based Biosensing System for Glucose Fabricated by Using Track-etched Microporous Membrane Electrodes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T20%3A17%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-chemicalsocietyjapan_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Flow-based%20Biosensing%20System%20for%20Glucose%20Fabricated%20by%20Using%20Track-etched%20Microporous%20Membrane%20Electrodes&rft.jtitle=Chemistry%20letters&rft.au=Mizuguchi,%20Hitoshi&rft.date=2013-10-05&rft.volume=42&rft.issue=10&rft.spage=1317&rft.epage=1319&rft.pages=1317-1319&rft.issn=0366-7022&rft.eissn=1348-0715&rft_id=info:doi/10.1246/cl.130594&rft_dat=%3Cchemicalsocietyjapan_cross%3E10_1246_cl_130594%3C/chemicalsocietyjapan_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |