Do on-demand irrigation warmers provide an adequate intraoperative rate of irrigation for holmium enucleation of the prostate?

Introduction: On-demand irrigation warmers are widely used to provide a convenient way of irrigating warmed fluids for endoscopic procedure. However, concern has been raised that flow rates via these devices are inadequate for safe operating. Holmium enucleation of prostate (HoLEP) requires signific...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical urology 2016-07, Vol.9 (4), p.244-247
Hauptverfasser: Chapman, Richard Alexander, Halliday, Paul
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 247
container_issue 4
container_start_page 244
container_title Journal of clinical urology
container_volume 9
creator Chapman, Richard Alexander
Halliday, Paul
description Introduction: On-demand irrigation warmers are widely used to provide a convenient way of irrigating warmed fluids for endoscopic procedure. However, concern has been raised that flow rates via these devices are inadequate for safe operating. Holmium enucleation of prostate (HoLEP) requires significant volume and flow rate of irrigation. Poiseuille’s Law states the resistance of a tube will result in reduced flow and a reduction in pressure across the tube. The aim was to compare the irrigation rates provided by one such warming device compared to a standard giving set whilst simulating HoLEP and to monitor intravesical pressure. Methods: A simulated apparatus was set up to replicate HoLEP surgery. Simulated design rather than ‘real-life’ apparatus was used to allow for repeated testing in a more controlled environment and to avoid other variables due to operative differences. Comparison of irrigation rate and pressure difference was measured whilst using a standard irrigation set (Fresenius Kabi) with pre-warmed fluid and the Ranger irrigation warming system (3M). Pressure was measured using a pressure line passed via the working channel of the laser resectoscope. Results: The standard giving set demonstrated lower resistance and higher irrigation rates. The irrigation rate was 31% higher (7.2 vs 5.5 ml/s). A lower change in pressure across the standard giving set was found (20 vs 38 cm H2O). The resistance therefore is much higher in the Ranger irrigation system, which gave a much slower flow and greater drop in pressure. Conclusion: This unique demonstration has led to a quantitative assessment of commonly used giving sets and has shown irrigation rates via a standard giving set are 31% greater than through the Ranger irrigation warming system. On-demand fluid warmers are felt to result in poor intraoperative vision and pose a potential risk to patient safety during HoLEP and other urological procedures requiring high fluid volumes.
doi_str_mv 10.1177/2051415815623123
format Article
fullrecord <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_2051415815623123</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_2051415815623123</sage_id><sourcerecordid>10.1177_2051415815623123</sourcerecordid><originalsourceid>FETCH-LOGICAL-c234t-a872cb6ae317fff8ad4bb04689680fb3f7cf5216a05d93119fed5ef52800e7b13</originalsourceid><addsrcrecordid>eNp1kEtPwzAQhC0EElXpnaP_QMCPOHFOCJWnVIkLnKNNvG6NGrs4SREXfjuOyqFC4rSrTzOzqyHkkrMrzsvyWjDFc640V4WQXMgTMptQNrHTo_2cLPreNUxJWXGh2Yx83wUafGawA2-oi9GtYXDB00-IHcae7mLYO4MUPAWDHyMMSJ0fIoQdxiTdI40TC_bYbUOkm7Dt3NhR9GO7xQNPqmGDU2g_JNfNBTmzsO1x8Tvn5O3h_nX5lK1eHp-Xt6usFTIfMtClaJsCUPLSWqvB5E3D8kJXhWa2kbZsrRK8AKZMJTmvLBqFCWnGsGy4nBN2yG3T5T6irXfRdRC_as7qqcL6b4XJkh0sPayxfg9j9OnD__U_kUFzoA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Do on-demand irrigation warmers provide an adequate intraoperative rate of irrigation for holmium enucleation of the prostate?</title><source>SAGE Complete A-Z List</source><source>Alma/SFX Local Collection</source><creator>Chapman, Richard Alexander ; Halliday, Paul</creator><creatorcontrib>Chapman, Richard Alexander ; Halliday, Paul</creatorcontrib><description>Introduction: On-demand irrigation warmers are widely used to provide a convenient way of irrigating warmed fluids for endoscopic procedure. However, concern has been raised that flow rates via these devices are inadequate for safe operating. Holmium enucleation of prostate (HoLEP) requires significant volume and flow rate of irrigation. Poiseuille’s Law states the resistance of a tube will result in reduced flow and a reduction in pressure across the tube. The aim was to compare the irrigation rates provided by one such warming device compared to a standard giving set whilst simulating HoLEP and to monitor intravesical pressure. Methods: A simulated apparatus was set up to replicate HoLEP surgery. Simulated design rather than ‘real-life’ apparatus was used to allow for repeated testing in a more controlled environment and to avoid other variables due to operative differences. Comparison of irrigation rate and pressure difference was measured whilst using a standard irrigation set (Fresenius Kabi) with pre-warmed fluid and the Ranger irrigation warming system (3M). Pressure was measured using a pressure line passed via the working channel of the laser resectoscope. Results: The standard giving set demonstrated lower resistance and higher irrigation rates. The irrigation rate was 31% higher (7.2 vs 5.5 ml/s). A lower change in pressure across the standard giving set was found (20 vs 38 cm H2O). The resistance therefore is much higher in the Ranger irrigation system, which gave a much slower flow and greater drop in pressure. Conclusion: This unique demonstration has led to a quantitative assessment of commonly used giving sets and has shown irrigation rates via a standard giving set are 31% greater than through the Ranger irrigation warming system. On-demand fluid warmers are felt to result in poor intraoperative vision and pose a potential risk to patient safety during HoLEP and other urological procedures requiring high fluid volumes.</description><identifier>ISSN: 2051-4158</identifier><identifier>EISSN: 2051-4158</identifier><identifier>EISSN: 2051-4166</identifier><identifier>DOI: 10.1177/2051415815623123</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Journal of clinical urology, 2016-07, Vol.9 (4), p.244-247</ispartof><rights>British Association of Urological Surgeons 2016</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c234t-a872cb6ae317fff8ad4bb04689680fb3f7cf5216a05d93119fed5ef52800e7b13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/2051415815623123$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/2051415815623123$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids></links><search><creatorcontrib>Chapman, Richard Alexander</creatorcontrib><creatorcontrib>Halliday, Paul</creatorcontrib><title>Do on-demand irrigation warmers provide an adequate intraoperative rate of irrigation for holmium enucleation of the prostate?</title><title>Journal of clinical urology</title><description>Introduction: On-demand irrigation warmers are widely used to provide a convenient way of irrigating warmed fluids for endoscopic procedure. However, concern has been raised that flow rates via these devices are inadequate for safe operating. Holmium enucleation of prostate (HoLEP) requires significant volume and flow rate of irrigation. Poiseuille’s Law states the resistance of a tube will result in reduced flow and a reduction in pressure across the tube. The aim was to compare the irrigation rates provided by one such warming device compared to a standard giving set whilst simulating HoLEP and to monitor intravesical pressure. Methods: A simulated apparatus was set up to replicate HoLEP surgery. Simulated design rather than ‘real-life’ apparatus was used to allow for repeated testing in a more controlled environment and to avoid other variables due to operative differences. Comparison of irrigation rate and pressure difference was measured whilst using a standard irrigation set (Fresenius Kabi) with pre-warmed fluid and the Ranger irrigation warming system (3M). Pressure was measured using a pressure line passed via the working channel of the laser resectoscope. Results: The standard giving set demonstrated lower resistance and higher irrigation rates. The irrigation rate was 31% higher (7.2 vs 5.5 ml/s). A lower change in pressure across the standard giving set was found (20 vs 38 cm H2O). The resistance therefore is much higher in the Ranger irrigation system, which gave a much slower flow and greater drop in pressure. Conclusion: This unique demonstration has led to a quantitative assessment of commonly used giving sets and has shown irrigation rates via a standard giving set are 31% greater than through the Ranger irrigation warming system. On-demand fluid warmers are felt to result in poor intraoperative vision and pose a potential risk to patient safety during HoLEP and other urological procedures requiring high fluid volumes.</description><issn>2051-4158</issn><issn>2051-4158</issn><issn>2051-4166</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNp1kEtPwzAQhC0EElXpnaP_QMCPOHFOCJWnVIkLnKNNvG6NGrs4SREXfjuOyqFC4rSrTzOzqyHkkrMrzsvyWjDFc640V4WQXMgTMptQNrHTo_2cLPreNUxJWXGh2Yx83wUafGawA2-oi9GtYXDB00-IHcae7mLYO4MUPAWDHyMMSJ0fIoQdxiTdI40TC_bYbUOkm7Dt3NhR9GO7xQNPqmGDU2g_JNfNBTmzsO1x8Tvn5O3h_nX5lK1eHp-Xt6usFTIfMtClaJsCUPLSWqvB5E3D8kJXhWa2kbZsrRK8AKZMJTmvLBqFCWnGsGy4nBN2yG3T5T6irXfRdRC_as7qqcL6b4XJkh0sPayxfg9j9OnD__U_kUFzoA</recordid><startdate>201607</startdate><enddate>201607</enddate><creator>Chapman, Richard Alexander</creator><creator>Halliday, Paul</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201607</creationdate><title>Do on-demand irrigation warmers provide an adequate intraoperative rate of irrigation for holmium enucleation of the prostate?</title><author>Chapman, Richard Alexander ; Halliday, Paul</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c234t-a872cb6ae317fff8ad4bb04689680fb3f7cf5216a05d93119fed5ef52800e7b13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chapman, Richard Alexander</creatorcontrib><creatorcontrib>Halliday, Paul</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of clinical urology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chapman, Richard Alexander</au><au>Halliday, Paul</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Do on-demand irrigation warmers provide an adequate intraoperative rate of irrigation for holmium enucleation of the prostate?</atitle><jtitle>Journal of clinical urology</jtitle><date>2016-07</date><risdate>2016</risdate><volume>9</volume><issue>4</issue><spage>244</spage><epage>247</epage><pages>244-247</pages><issn>2051-4158</issn><eissn>2051-4158</eissn><eissn>2051-4166</eissn><abstract>Introduction: On-demand irrigation warmers are widely used to provide a convenient way of irrigating warmed fluids for endoscopic procedure. However, concern has been raised that flow rates via these devices are inadequate for safe operating. Holmium enucleation of prostate (HoLEP) requires significant volume and flow rate of irrigation. Poiseuille’s Law states the resistance of a tube will result in reduced flow and a reduction in pressure across the tube. The aim was to compare the irrigation rates provided by one such warming device compared to a standard giving set whilst simulating HoLEP and to monitor intravesical pressure. Methods: A simulated apparatus was set up to replicate HoLEP surgery. Simulated design rather than ‘real-life’ apparatus was used to allow for repeated testing in a more controlled environment and to avoid other variables due to operative differences. Comparison of irrigation rate and pressure difference was measured whilst using a standard irrigation set (Fresenius Kabi) with pre-warmed fluid and the Ranger irrigation warming system (3M). Pressure was measured using a pressure line passed via the working channel of the laser resectoscope. Results: The standard giving set demonstrated lower resistance and higher irrigation rates. The irrigation rate was 31% higher (7.2 vs 5.5 ml/s). A lower change in pressure across the standard giving set was found (20 vs 38 cm H2O). The resistance therefore is much higher in the Ranger irrigation system, which gave a much slower flow and greater drop in pressure. Conclusion: This unique demonstration has led to a quantitative assessment of commonly used giving sets and has shown irrigation rates via a standard giving set are 31% greater than through the Ranger irrigation warming system. On-demand fluid warmers are felt to result in poor intraoperative vision and pose a potential risk to patient safety during HoLEP and other urological procedures requiring high fluid volumes.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/2051415815623123</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2051-4158
ispartof Journal of clinical urology, 2016-07, Vol.9 (4), p.244-247
issn 2051-4158
2051-4158
2051-4166
language eng
recordid cdi_crossref_primary_10_1177_2051415815623123
source SAGE Complete A-Z List; Alma/SFX Local Collection
title Do on-demand irrigation warmers provide an adequate intraoperative rate of irrigation for holmium enucleation of the prostate?
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T21%3A28%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Do%20on-demand%20irrigation%20warmers%20provide%20an%20adequate%20intraoperative%20rate%20of%20irrigation%20for%20holmium%20enucleation%20of%20the%20prostate?&rft.jtitle=Journal%20of%20clinical%20urology&rft.au=Chapman,%20Richard%20Alexander&rft.date=2016-07&rft.volume=9&rft.issue=4&rft.spage=244&rft.epage=247&rft.pages=244-247&rft.issn=2051-4158&rft.eissn=2051-4158&rft_id=info:doi/10.1177/2051415815623123&rft_dat=%3Csage_cross%3E10.1177_2051415815623123%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_2051415815623123&rfr_iscdi=true