A methodology for hygrothermal modelling of imperfect masonry interfaces

Hygrothermal models are important tools for assessing the risk of moisture-related decay mechanisms which can compromise structural integrity, loss of architectural features and material. There are several sources of uncertainty when modelling masonry, related to material properties, boundary condit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of building physics 2021-05, Vol.44 (6), p.485-509
Hauptverfasser: Gutland, Michael, Bucking, Scott, Santana Quintero, Mario
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 509
container_issue 6
container_start_page 485
container_title Journal of building physics
container_volume 44
creator Gutland, Michael
Bucking, Scott
Santana Quintero, Mario
description Hygrothermal models are important tools for assessing the risk of moisture-related decay mechanisms which can compromise structural integrity, loss of architectural features and material. There are several sources of uncertainty when modelling masonry, related to material properties, boundary conditions, quality of construction and two-dimensional interactions between mortar and unit. This paper examines the uncertainty at the mortar-unit interface with imperfections such as hairline cracks or imperfect contact conditions. These imperfections will alter the rate of liquid transport into and out of the wall and impede the liquid transport between mortar and masonry unit. This means that the effective liquid transport of the wall system will be different then if only properties of the bulk material were modelled. A detailed methodology for modelling this interface as a fracture is presented including definition of material properties for the fracture. The modelling methodology considers the combined effect of both the interface resistance across the mortar-unit interface and increase liquid transport in parallel to the interface, and is generalisable to various combinations of materials, geometries and fracture apertures. Two-dimensional DELPHIN models of a clay brick/cement-mortar masonry wall were created to simulate this interaction. The models were exposed to different boundary conditions to simulate wetting, drying and natural cyclic weather conditions. The results of these simulations were compared to a baseline model where the fracture model was not included. The presence of fractures increased the rate of absorption in the wetting phase and an increased rate of desorption in the drying phase. Under cyclic conditions, the result was higher peak moisture contents after rain events compared to baseline and lower moisture contents after long periods of drying. This demonstrated that detailed modelling of imperfections at the mortar-unit interface can have a definitive influence on results and conclusions from hygrothermal simulations.
doi_str_mv 10.1177/1744259121989388
format Article
fullrecord <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_1744259121989388</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1744259121989388</sage_id><sourcerecordid>10.1177_1744259121989388</sourcerecordid><originalsourceid>FETCH-LOGICAL-c323t-59f81a4ffc7e839be2168bc459daa80573ee5ef22316dbfe1e2a998ec50889f43</originalsourceid><addsrcrecordid>eNp1ULFqwzAUFKWBpkn3jvoBt3qSFUtjCG1TCHRpZyPLT7aDZQXJHfz3dUjpUMh0x3F3HEfII7AngKJ4hiLPudTAQSstlLohy7OUcanE7R_XcEfuUzoyJjQALMl-Sz2ObahDH5qJuhBpOzUxjC1Gb3rqQ4193w0NDY52_oTRoR2pNykMcaLdMM6KsZjWZOFMn_DhF1fk6_Xlc7fPDh9v77vtIbOCizGT2ikwuXO2QCV0hRw2qrK51LUxislCIEp0nAvY1JVDQG60VmglU0q7XKwIu_TaGFKK6MpT7LyJUwmsPD9R_n9ijmSXSDINlsfwHYd54XX_DztPXzA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A methodology for hygrothermal modelling of imperfect masonry interfaces</title><source>Access via SAGE</source><source>Alma/SFX Local Collection</source><creator>Gutland, Michael ; Bucking, Scott ; Santana Quintero, Mario</creator><creatorcontrib>Gutland, Michael ; Bucking, Scott ; Santana Quintero, Mario</creatorcontrib><description>Hygrothermal models are important tools for assessing the risk of moisture-related decay mechanisms which can compromise structural integrity, loss of architectural features and material. There are several sources of uncertainty when modelling masonry, related to material properties, boundary conditions, quality of construction and two-dimensional interactions between mortar and unit. This paper examines the uncertainty at the mortar-unit interface with imperfections such as hairline cracks or imperfect contact conditions. These imperfections will alter the rate of liquid transport into and out of the wall and impede the liquid transport between mortar and masonry unit. This means that the effective liquid transport of the wall system will be different then if only properties of the bulk material were modelled. A detailed methodology for modelling this interface as a fracture is presented including definition of material properties for the fracture. The modelling methodology considers the combined effect of both the interface resistance across the mortar-unit interface and increase liquid transport in parallel to the interface, and is generalisable to various combinations of materials, geometries and fracture apertures. Two-dimensional DELPHIN models of a clay brick/cement-mortar masonry wall were created to simulate this interaction. The models were exposed to different boundary conditions to simulate wetting, drying and natural cyclic weather conditions. The results of these simulations were compared to a baseline model where the fracture model was not included. The presence of fractures increased the rate of absorption in the wetting phase and an increased rate of desorption in the drying phase. Under cyclic conditions, the result was higher peak moisture contents after rain events compared to baseline and lower moisture contents after long periods of drying. This demonstrated that detailed modelling of imperfections at the mortar-unit interface can have a definitive influence on results and conclusions from hygrothermal simulations.</description><identifier>ISSN: 1744-2591</identifier><identifier>EISSN: 1744-2583</identifier><identifier>DOI: 10.1177/1744259121989388</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Journal of building physics, 2021-05, Vol.44 (6), p.485-509</ispartof><rights>The Author(s) 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c323t-59f81a4ffc7e839be2168bc459daa80573ee5ef22316dbfe1e2a998ec50889f43</citedby><cites>FETCH-LOGICAL-c323t-59f81a4ffc7e839be2168bc459daa80573ee5ef22316dbfe1e2a998ec50889f43</cites><orcidid>0000-0001-8907-4046 ; 0000-0002-3836-9714</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1744259121989388$$EPDF$$P50$$Gsage$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1744259121989388$$EHTML$$P50$$Gsage$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids></links><search><creatorcontrib>Gutland, Michael</creatorcontrib><creatorcontrib>Bucking, Scott</creatorcontrib><creatorcontrib>Santana Quintero, Mario</creatorcontrib><title>A methodology for hygrothermal modelling of imperfect masonry interfaces</title><title>Journal of building physics</title><description>Hygrothermal models are important tools for assessing the risk of moisture-related decay mechanisms which can compromise structural integrity, loss of architectural features and material. There are several sources of uncertainty when modelling masonry, related to material properties, boundary conditions, quality of construction and two-dimensional interactions between mortar and unit. This paper examines the uncertainty at the mortar-unit interface with imperfections such as hairline cracks or imperfect contact conditions. These imperfections will alter the rate of liquid transport into and out of the wall and impede the liquid transport between mortar and masonry unit. This means that the effective liquid transport of the wall system will be different then if only properties of the bulk material were modelled. A detailed methodology for modelling this interface as a fracture is presented including definition of material properties for the fracture. The modelling methodology considers the combined effect of both the interface resistance across the mortar-unit interface and increase liquid transport in parallel to the interface, and is generalisable to various combinations of materials, geometries and fracture apertures. Two-dimensional DELPHIN models of a clay brick/cement-mortar masonry wall were created to simulate this interaction. The models were exposed to different boundary conditions to simulate wetting, drying and natural cyclic weather conditions. The results of these simulations were compared to a baseline model where the fracture model was not included. The presence of fractures increased the rate of absorption in the wetting phase and an increased rate of desorption in the drying phase. Under cyclic conditions, the result was higher peak moisture contents after rain events compared to baseline and lower moisture contents after long periods of drying. This demonstrated that detailed modelling of imperfections at the mortar-unit interface can have a definitive influence on results and conclusions from hygrothermal simulations.</description><issn>1744-2591</issn><issn>1744-2583</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>AFRWT</sourceid><recordid>eNp1ULFqwzAUFKWBpkn3jvoBt3qSFUtjCG1TCHRpZyPLT7aDZQXJHfz3dUjpUMh0x3F3HEfII7AngKJ4hiLPudTAQSstlLohy7OUcanE7R_XcEfuUzoyJjQALMl-Sz2ObahDH5qJuhBpOzUxjC1Gb3rqQ4193w0NDY52_oTRoR2pNykMcaLdMM6KsZjWZOFMn_DhF1fk6_Xlc7fPDh9v77vtIbOCizGT2ikwuXO2QCV0hRw2qrK51LUxislCIEp0nAvY1JVDQG60VmglU0q7XKwIu_TaGFKK6MpT7LyJUwmsPD9R_n9ijmSXSDINlsfwHYd54XX_DztPXzA</recordid><startdate>202105</startdate><enddate>202105</enddate><creator>Gutland, Michael</creator><creator>Bucking, Scott</creator><creator>Santana Quintero, Mario</creator><general>SAGE Publications</general><scope>AFRWT</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-8907-4046</orcidid><orcidid>https://orcid.org/0000-0002-3836-9714</orcidid></search><sort><creationdate>202105</creationdate><title>A methodology for hygrothermal modelling of imperfect masonry interfaces</title><author>Gutland, Michael ; Bucking, Scott ; Santana Quintero, Mario</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c323t-59f81a4ffc7e839be2168bc459daa80573ee5ef22316dbfe1e2a998ec50889f43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gutland, Michael</creatorcontrib><creatorcontrib>Bucking, Scott</creatorcontrib><creatorcontrib>Santana Quintero, Mario</creatorcontrib><collection>Sage Journals GOLD Open Access 2024</collection><collection>CrossRef</collection><jtitle>Journal of building physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gutland, Michael</au><au>Bucking, Scott</au><au>Santana Quintero, Mario</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A methodology for hygrothermal modelling of imperfect masonry interfaces</atitle><jtitle>Journal of building physics</jtitle><date>2021-05</date><risdate>2021</risdate><volume>44</volume><issue>6</issue><spage>485</spage><epage>509</epage><pages>485-509</pages><issn>1744-2591</issn><eissn>1744-2583</eissn><abstract>Hygrothermal models are important tools for assessing the risk of moisture-related decay mechanisms which can compromise structural integrity, loss of architectural features and material. There are several sources of uncertainty when modelling masonry, related to material properties, boundary conditions, quality of construction and two-dimensional interactions between mortar and unit. This paper examines the uncertainty at the mortar-unit interface with imperfections such as hairline cracks or imperfect contact conditions. These imperfections will alter the rate of liquid transport into and out of the wall and impede the liquid transport between mortar and masonry unit. This means that the effective liquid transport of the wall system will be different then if only properties of the bulk material were modelled. A detailed methodology for modelling this interface as a fracture is presented including definition of material properties for the fracture. The modelling methodology considers the combined effect of both the interface resistance across the mortar-unit interface and increase liquid transport in parallel to the interface, and is generalisable to various combinations of materials, geometries and fracture apertures. Two-dimensional DELPHIN models of a clay brick/cement-mortar masonry wall were created to simulate this interaction. The models were exposed to different boundary conditions to simulate wetting, drying and natural cyclic weather conditions. The results of these simulations were compared to a baseline model where the fracture model was not included. The presence of fractures increased the rate of absorption in the wetting phase and an increased rate of desorption in the drying phase. Under cyclic conditions, the result was higher peak moisture contents after rain events compared to baseline and lower moisture contents after long periods of drying. This demonstrated that detailed modelling of imperfections at the mortar-unit interface can have a definitive influence on results and conclusions from hygrothermal simulations.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/1744259121989388</doi><tpages>25</tpages><orcidid>https://orcid.org/0000-0001-8907-4046</orcidid><orcidid>https://orcid.org/0000-0002-3836-9714</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1744-2591
ispartof Journal of building physics, 2021-05, Vol.44 (6), p.485-509
issn 1744-2591
1744-2583
language eng
recordid cdi_crossref_primary_10_1177_1744259121989388
source Access via SAGE; Alma/SFX Local Collection
title A methodology for hygrothermal modelling of imperfect masonry interfaces
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T11%3A58%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20methodology%20for%20hygrothermal%20modelling%20of%20imperfect%20masonry%20interfaces&rft.jtitle=Journal%20of%20building%20physics&rft.au=Gutland,%20Michael&rft.date=2021-05&rft.volume=44&rft.issue=6&rft.spage=485&rft.epage=509&rft.pages=485-509&rft.issn=1744-2591&rft.eissn=1744-2583&rft_id=info:doi/10.1177/1744259121989388&rft_dat=%3Csage_cross%3E10.1177_1744259121989388%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_1744259121989388&rfr_iscdi=true