3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision: A Case-Control Analysis

Background. The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Study design. Between September 2012 and September 2015, we randomized 36 patients affected by...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgical innovation 2017-04, Vol.24 (2), p.155-161
Hauptverfasser: Leon, Piera, Rivellini, Roberta, Giudici, Fabiola, Sciuto, Antonio, Pirozzi, Felice, Corcione, Francesco
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 161
container_issue 2
container_start_page 155
container_title Surgical innovation
container_volume 24
creator Leon, Piera
Rivellini, Roberta
Giudici, Fabiola
Sciuto, Antonio
Pirozzi, Felice
Corcione, Francesco
description Background. The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Study design. Between September 2012 and September 2015, we randomized 36 patients affected by symptomatic HH to undergo surgery; 17 patients underwent 2D laparoscopic HH repair, whereas 19 patients underwent the same operation in 3D vision. Results. No conversion to open surgery occurred. Overall operative time was significantly reduced in the 3D laparoscopic group compared with the 2D one (69.9 vs 90.1 minutes, P = .006). Operative time to perform laparoscopic crura closure did not differ significantly between the 2 groups. We observed a tendency to a faster crura closure in the 3D group in the subgroup of patients with mesh positioning (7.5 vs 8.9 minutes, P = .09). Nissen fundoplication was faster in the 3D group without mesh positioning (P = .07). Conclusions. 3D vision in laparoscopic HH repair helps surgeon’s visualization and seems to lead to operative time reduction. Advantages can result from the enhanced spatial perception of narrow spaces. Less operative time and more accurate surgery translate to benefit for patients and cost savings, compensating the high costs of the 3D technology. However, more data from larger series are needed to firmly assess the advantages of 3D over 2D vision in laparoscopic HH repair.
doi_str_mv 10.1177/1553350616687434
format Article
fullrecord <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_1553350616687434</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1553350616687434</sage_id><sourcerecordid>10.1177_1553350616687434</sourcerecordid><originalsourceid>FETCH-LOGICAL-c164t-29873858aae8fd889d46c20ebf0acbb011e95b7c0b2d0a396031526de75b4df23</originalsourceid><addsrcrecordid>eNp1kE9PwkAQxTdGExG9e5wvUN3tdttyJPgHEgxEUI_NdDuFJbTb7BYSv4sf1hKUg4mnmcz7vcnLY-xW8DshkuReKCWl4rGI4zSJZHTGeodTIJWIzk87jy_ZlfcbziMluOqxL_kA78YbW8Pc2b0pyMNibV1LDmYNOWzNnmBpKgKsC3ixjmCo9a4TCCZ169CeqMXOrYzGLczJldZVWGsCU8MUG3TWa9sYDWODbYeMydUG4ZUaNA5GtuoQKuDDtGsIfyNds4sSt55ufmafvT09LkfjYDp7noyG00CLOGqDcJAmMlUpIqVlkaaDIop1yCkvOeo850LQQOWJ5nlYcJSDmEuhwrigROVRUYayz_jxr-5iekdl1jhTofvMBM8O7WZ_2-0swdHicUXZxu5c3SX8n_8Gtg178w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision: A Case-Control Analysis</title><source>SAGE Complete A-Z List</source><source>Alma/SFX Local Collection</source><creator>Leon, Piera ; Rivellini, Roberta ; Giudici, Fabiola ; Sciuto, Antonio ; Pirozzi, Felice ; Corcione, Francesco</creator><creatorcontrib>Leon, Piera ; Rivellini, Roberta ; Giudici, Fabiola ; Sciuto, Antonio ; Pirozzi, Felice ; Corcione, Francesco</creatorcontrib><description>Background. The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Study design. Between September 2012 and September 2015, we randomized 36 patients affected by symptomatic HH to undergo surgery; 17 patients underwent 2D laparoscopic HH repair, whereas 19 patients underwent the same operation in 3D vision. Results. No conversion to open surgery occurred. Overall operative time was significantly reduced in the 3D laparoscopic group compared with the 2D one (69.9 vs 90.1 minutes, P = .006). Operative time to perform laparoscopic crura closure did not differ significantly between the 2 groups. We observed a tendency to a faster crura closure in the 3D group in the subgroup of patients with mesh positioning (7.5 vs 8.9 minutes, P = .09). Nissen fundoplication was faster in the 3D group without mesh positioning (P = .07). Conclusions. 3D vision in laparoscopic HH repair helps surgeon’s visualization and seems to lead to operative time reduction. Advantages can result from the enhanced spatial perception of narrow spaces. Less operative time and more accurate surgery translate to benefit for patients and cost savings, compensating the high costs of the 3D technology. However, more data from larger series are needed to firmly assess the advantages of 3D over 2D vision in laparoscopic HH repair.</description><identifier>ISSN: 1553-3506</identifier><identifier>EISSN: 1553-3514</identifier><identifier>DOI: 10.1177/1553350616687434</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><ispartof>Surgical innovation, 2017-04, Vol.24 (2), p.155-161</ispartof><rights>The Author(s) 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c164t-29873858aae8fd889d46c20ebf0acbb011e95b7c0b2d0a396031526de75b4df23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1553350616687434$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1553350616687434$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,778,782,21806,27911,27912,43608,43609</link.rule.ids></links><search><creatorcontrib>Leon, Piera</creatorcontrib><creatorcontrib>Rivellini, Roberta</creatorcontrib><creatorcontrib>Giudici, Fabiola</creatorcontrib><creatorcontrib>Sciuto, Antonio</creatorcontrib><creatorcontrib>Pirozzi, Felice</creatorcontrib><creatorcontrib>Corcione, Francesco</creatorcontrib><title>3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision: A Case-Control Analysis</title><title>Surgical innovation</title><addtitle>Surg Innov</addtitle><description>Background. The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Study design. Between September 2012 and September 2015, we randomized 36 patients affected by symptomatic HH to undergo surgery; 17 patients underwent 2D laparoscopic HH repair, whereas 19 patients underwent the same operation in 3D vision. Results. No conversion to open surgery occurred. Overall operative time was significantly reduced in the 3D laparoscopic group compared with the 2D one (69.9 vs 90.1 minutes, P = .006). Operative time to perform laparoscopic crura closure did not differ significantly between the 2 groups. We observed a tendency to a faster crura closure in the 3D group in the subgroup of patients with mesh positioning (7.5 vs 8.9 minutes, P = .09). Nissen fundoplication was faster in the 3D group without mesh positioning (P = .07). Conclusions. 3D vision in laparoscopic HH repair helps surgeon’s visualization and seems to lead to operative time reduction. Advantages can result from the enhanced spatial perception of narrow spaces. Less operative time and more accurate surgery translate to benefit for patients and cost savings, compensating the high costs of the 3D technology. However, more data from larger series are needed to firmly assess the advantages of 3D over 2D vision in laparoscopic HH repair.</description><issn>1553-3506</issn><issn>1553-3514</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp1kE9PwkAQxTdGExG9e5wvUN3tdttyJPgHEgxEUI_NdDuFJbTb7BYSv4sf1hKUg4mnmcz7vcnLY-xW8DshkuReKCWl4rGI4zSJZHTGeodTIJWIzk87jy_ZlfcbziMluOqxL_kA78YbW8Pc2b0pyMNibV1LDmYNOWzNnmBpKgKsC3ixjmCo9a4TCCZ169CeqMXOrYzGLczJldZVWGsCU8MUG3TWa9sYDWODbYeMydUG4ZUaNA5GtuoQKuDDtGsIfyNds4sSt55ufmafvT09LkfjYDp7noyG00CLOGqDcJAmMlUpIqVlkaaDIop1yCkvOeo850LQQOWJ5nlYcJSDmEuhwrigROVRUYayz_jxr-5iekdl1jhTofvMBM8O7WZ_2-0swdHicUXZxu5c3SX8n_8Gtg178w</recordid><startdate>201704</startdate><enddate>201704</enddate><creator>Leon, Piera</creator><creator>Rivellini, Roberta</creator><creator>Giudici, Fabiola</creator><creator>Sciuto, Antonio</creator><creator>Pirozzi, Felice</creator><creator>Corcione, Francesco</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201704</creationdate><title>3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision</title><author>Leon, Piera ; Rivellini, Roberta ; Giudici, Fabiola ; Sciuto, Antonio ; Pirozzi, Felice ; Corcione, Francesco</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c164t-29873858aae8fd889d46c20ebf0acbb011e95b7c0b2d0a396031526de75b4df23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Leon, Piera</creatorcontrib><creatorcontrib>Rivellini, Roberta</creatorcontrib><creatorcontrib>Giudici, Fabiola</creatorcontrib><creatorcontrib>Sciuto, Antonio</creatorcontrib><creatorcontrib>Pirozzi, Felice</creatorcontrib><creatorcontrib>Corcione, Francesco</creatorcontrib><collection>CrossRef</collection><jtitle>Surgical innovation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Leon, Piera</au><au>Rivellini, Roberta</au><au>Giudici, Fabiola</au><au>Sciuto, Antonio</au><au>Pirozzi, Felice</au><au>Corcione, Francesco</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision: A Case-Control Analysis</atitle><jtitle>Surgical innovation</jtitle><addtitle>Surg Innov</addtitle><date>2017-04</date><risdate>2017</risdate><volume>24</volume><issue>2</issue><spage>155</spage><epage>161</epage><pages>155-161</pages><issn>1553-3506</issn><eissn>1553-3514</eissn><abstract>Background. The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Study design. Between September 2012 and September 2015, we randomized 36 patients affected by symptomatic HH to undergo surgery; 17 patients underwent 2D laparoscopic HH repair, whereas 19 patients underwent the same operation in 3D vision. Results. No conversion to open surgery occurred. Overall operative time was significantly reduced in the 3D laparoscopic group compared with the 2D one (69.9 vs 90.1 minutes, P = .006). Operative time to perform laparoscopic crura closure did not differ significantly between the 2 groups. We observed a tendency to a faster crura closure in the 3D group in the subgroup of patients with mesh positioning (7.5 vs 8.9 minutes, P = .09). Nissen fundoplication was faster in the 3D group without mesh positioning (P = .07). Conclusions. 3D vision in laparoscopic HH repair helps surgeon’s visualization and seems to lead to operative time reduction. Advantages can result from the enhanced spatial perception of narrow spaces. Less operative time and more accurate surgery translate to benefit for patients and cost savings, compensating the high costs of the 3D technology. However, more data from larger series are needed to firmly assess the advantages of 3D over 2D vision in laparoscopic HH repair.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><doi>10.1177/1553350616687434</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1553-3506
ispartof Surgical innovation, 2017-04, Vol.24 (2), p.155-161
issn 1553-3506
1553-3514
language eng
recordid cdi_crossref_primary_10_1177_1553350616687434
source SAGE Complete A-Z List; Alma/SFX Local Collection
title 3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision: A Case-Control Analysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T22%3A17%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=3D%20Vision%20Provides%20Shorter%20Operative%20Time%20and%20More%20Accurate%20Intraoperative%20Surgical%20Performance%20in%20Laparoscopic%20Hiatal%20Hernia%20Repair%20Compared%20With%202D%20Vision:%20A%20Case-Control%20Analysis&rft.jtitle=Surgical%20innovation&rft.au=Leon,%20Piera&rft.date=2017-04&rft.volume=24&rft.issue=2&rft.spage=155&rft.epage=161&rft.pages=155-161&rft.issn=1553-3506&rft.eissn=1553-3514&rft_id=info:doi/10.1177/1553350616687434&rft_dat=%3Csage_cross%3E10.1177_1553350616687434%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_1553350616687434&rfr_iscdi=true