A numerical research on transient transport of high-temperature particles associated with air gouging process

The high-temperature particles produced by air gouging processes are common pollutants in cleaning workshops, which could endanger workers’ health. In this research, a two-way coupled Eulerian-Lagrangian method based on discrete phase modelling (DPM) was used to investigate the transport characteris...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Indoor + built environment 2024-08, Vol.33 (7), p.1335-1352
Hauptverfasser: Han, Kun, Zhuang, Jiawei, Zhang, Li’an, Diao, Yongfa
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1352
container_issue 7
container_start_page 1335
container_title Indoor + built environment
container_volume 33
creator Han, Kun
Zhuang, Jiawei
Zhang, Li’an
Diao, Yongfa
description The high-temperature particles produced by air gouging processes are common pollutants in cleaning workshops, which could endanger workers’ health. In this research, a two-way coupled Eulerian-Lagrangian method based on discrete phase modelling (DPM) was used to investigate the transport characteristics of high-temperature particles generated from air gouging processes. The particle group in the movement was divided into core zone and boundary zone, and the kinetic mechanism of particles in different zones was analysed. The results show particles in the boundary zone are more susceptible to the vortex entrainment effect than particles in the core zone, and some particles could be moved from the vortex diffusion zone to the vortex recirculation zone. The smaller the particle size, the better the followability to the hot airflow. The slower the temperature decay of particles, the more significant the thermophoresis effect, which could enhance the diffusion behaviour of the small particles. By analysing the average residence time of particles in the breathing zone, the influence of different factors on the average vertical diffusion height h p ¯ of particles is summarized, and a nonlinear regression prediction model of h p ¯ is established. The results can contribute to health risk assessment and industrial ventilation design.
doi_str_mv 10.1177/1420326X241240112
format Article
fullrecord <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_1420326X241240112</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1420326X241240112</sage_id><sourcerecordid>10.1177_1420326X241240112</sourcerecordid><originalsourceid>FETCH-LOGICAL-c284t-392788a3e78e871ba59030324c66cb670f41669a74aa1675ed6373df575ac6da3</originalsourceid><addsrcrecordid>eNp9kFtLw0AQhRdRsFZ_gG_7B1L3lt30sRRvIPii4FuYbibJlubC7Abx35ta3wSf5jDMdzhzGLuVYiWlc3fSKKGV_VBGKiOkVGdsMe90JoQT5z9aZMeDS3YV414IpYQzC9ZteD91SMHDgRNGBPItH3qeCPoYsE8nNQ6U-FDzNjRtlrAbkSBNhHwESsEfMHKIcfABElb8M6SWQyDeDFMT-oaPNHiM8Zpd1HCIePM7l-z94f5t-5S9vD4-bzcvmVeFSZleK1cUoNEVWDi5g3wt9Pye8db6nXWiNtLaNTgDIK3LsbLa6arOXQ7eVqCXTJ58PQ0xEtblSKED-iqlKI99lX_6mpnViYnQYLkfJurniP8A34iBbJs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A numerical research on transient transport of high-temperature particles associated with air gouging process</title><source>Access via SAGE</source><creator>Han, Kun ; Zhuang, Jiawei ; Zhang, Li’an ; Diao, Yongfa</creator><creatorcontrib>Han, Kun ; Zhuang, Jiawei ; Zhang, Li’an ; Diao, Yongfa</creatorcontrib><description>The high-temperature particles produced by air gouging processes are common pollutants in cleaning workshops, which could endanger workers’ health. In this research, a two-way coupled Eulerian-Lagrangian method based on discrete phase modelling (DPM) was used to investigate the transport characteristics of high-temperature particles generated from air gouging processes. The particle group in the movement was divided into core zone and boundary zone, and the kinetic mechanism of particles in different zones was analysed. The results show particles in the boundary zone are more susceptible to the vortex entrainment effect than particles in the core zone, and some particles could be moved from the vortex diffusion zone to the vortex recirculation zone. The smaller the particle size, the better the followability to the hot airflow. The slower the temperature decay of particles, the more significant the thermophoresis effect, which could enhance the diffusion behaviour of the small particles. By analysing the average residence time of particles in the breathing zone, the influence of different factors on the average vertical diffusion height h p ¯ of particles is summarized, and a nonlinear regression prediction model of h p ¯ is established. The results can contribute to health risk assessment and industrial ventilation design.</description><identifier>ISSN: 1420-326X</identifier><identifier>EISSN: 1423-0070</identifier><identifier>DOI: 10.1177/1420326X241240112</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Indoor + built environment, 2024-08, Vol.33 (7), p.1335-1352</ispartof><rights>The Author(s) 2024</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c284t-392788a3e78e871ba59030324c66cb670f41669a74aa1675ed6373df575ac6da3</citedby><cites>FETCH-LOGICAL-c284t-392788a3e78e871ba59030324c66cb670f41669a74aa1675ed6373df575ac6da3</cites><orcidid>0000-0001-6181-2203 ; 0000-0003-4277-6774</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1420326X241240112$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1420326X241240112$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids></links><search><creatorcontrib>Han, Kun</creatorcontrib><creatorcontrib>Zhuang, Jiawei</creatorcontrib><creatorcontrib>Zhang, Li’an</creatorcontrib><creatorcontrib>Diao, Yongfa</creatorcontrib><title>A numerical research on transient transport of high-temperature particles associated with air gouging process</title><title>Indoor + built environment</title><description>The high-temperature particles produced by air gouging processes are common pollutants in cleaning workshops, which could endanger workers’ health. In this research, a two-way coupled Eulerian-Lagrangian method based on discrete phase modelling (DPM) was used to investigate the transport characteristics of high-temperature particles generated from air gouging processes. The particle group in the movement was divided into core zone and boundary zone, and the kinetic mechanism of particles in different zones was analysed. The results show particles in the boundary zone are more susceptible to the vortex entrainment effect than particles in the core zone, and some particles could be moved from the vortex diffusion zone to the vortex recirculation zone. The smaller the particle size, the better the followability to the hot airflow. The slower the temperature decay of particles, the more significant the thermophoresis effect, which could enhance the diffusion behaviour of the small particles. By analysing the average residence time of particles in the breathing zone, the influence of different factors on the average vertical diffusion height h p ¯ of particles is summarized, and a nonlinear regression prediction model of h p ¯ is established. The results can contribute to health risk assessment and industrial ventilation design.</description><issn>1420-326X</issn><issn>1423-0070</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kFtLw0AQhRdRsFZ_gG_7B1L3lt30sRRvIPii4FuYbibJlubC7Abx35ta3wSf5jDMdzhzGLuVYiWlc3fSKKGV_VBGKiOkVGdsMe90JoQT5z9aZMeDS3YV414IpYQzC9ZteD91SMHDgRNGBPItH3qeCPoYsE8nNQ6U-FDzNjRtlrAbkSBNhHwESsEfMHKIcfABElb8M6SWQyDeDFMT-oaPNHiM8Zpd1HCIePM7l-z94f5t-5S9vD4-bzcvmVeFSZleK1cUoNEVWDi5g3wt9Pye8db6nXWiNtLaNTgDIK3LsbLa6arOXQ7eVqCXTJ58PQ0xEtblSKED-iqlKI99lX_6mpnViYnQYLkfJurniP8A34iBbJs</recordid><startdate>20240801</startdate><enddate>20240801</enddate><creator>Han, Kun</creator><creator>Zhuang, Jiawei</creator><creator>Zhang, Li’an</creator><creator>Diao, Yongfa</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-6181-2203</orcidid><orcidid>https://orcid.org/0000-0003-4277-6774</orcidid></search><sort><creationdate>20240801</creationdate><title>A numerical research on transient transport of high-temperature particles associated with air gouging process</title><author>Han, Kun ; Zhuang, Jiawei ; Zhang, Li’an ; Diao, Yongfa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c284t-392788a3e78e871ba59030324c66cb670f41669a74aa1675ed6373df575ac6da3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Han, Kun</creatorcontrib><creatorcontrib>Zhuang, Jiawei</creatorcontrib><creatorcontrib>Zhang, Li’an</creatorcontrib><creatorcontrib>Diao, Yongfa</creatorcontrib><collection>CrossRef</collection><jtitle>Indoor + built environment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Han, Kun</au><au>Zhuang, Jiawei</au><au>Zhang, Li’an</au><au>Diao, Yongfa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A numerical research on transient transport of high-temperature particles associated with air gouging process</atitle><jtitle>Indoor + built environment</jtitle><date>2024-08-01</date><risdate>2024</risdate><volume>33</volume><issue>7</issue><spage>1335</spage><epage>1352</epage><pages>1335-1352</pages><issn>1420-326X</issn><eissn>1423-0070</eissn><abstract>The high-temperature particles produced by air gouging processes are common pollutants in cleaning workshops, which could endanger workers’ health. In this research, a two-way coupled Eulerian-Lagrangian method based on discrete phase modelling (DPM) was used to investigate the transport characteristics of high-temperature particles generated from air gouging processes. The particle group in the movement was divided into core zone and boundary zone, and the kinetic mechanism of particles in different zones was analysed. The results show particles in the boundary zone are more susceptible to the vortex entrainment effect than particles in the core zone, and some particles could be moved from the vortex diffusion zone to the vortex recirculation zone. The smaller the particle size, the better the followability to the hot airflow. The slower the temperature decay of particles, the more significant the thermophoresis effect, which could enhance the diffusion behaviour of the small particles. By analysing the average residence time of particles in the breathing zone, the influence of different factors on the average vertical diffusion height h p ¯ of particles is summarized, and a nonlinear regression prediction model of h p ¯ is established. The results can contribute to health risk assessment and industrial ventilation design.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/1420326X241240112</doi><tpages>18</tpages><orcidid>https://orcid.org/0000-0001-6181-2203</orcidid><orcidid>https://orcid.org/0000-0003-4277-6774</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1420-326X
ispartof Indoor + built environment, 2024-08, Vol.33 (7), p.1335-1352
issn 1420-326X
1423-0070
language eng
recordid cdi_crossref_primary_10_1177_1420326X241240112
source Access via SAGE
title A numerical research on transient transport of high-temperature particles associated with air gouging process
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T09%3A48%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20numerical%20research%20on%20transient%20transport%20of%20high-temperature%20particles%20associated%20with%20air%20gouging%20process&rft.jtitle=Indoor%20+%20built%20environment&rft.au=Han,%20Kun&rft.date=2024-08-01&rft.volume=33&rft.issue=7&rft.spage=1335&rft.epage=1352&rft.pages=1335-1352&rft.issn=1420-326X&rft.eissn=1423-0070&rft_id=info:doi/10.1177/1420326X241240112&rft_dat=%3Csage_cross%3E10.1177_1420326X241240112%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_1420326X241240112&rfr_iscdi=true