Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment
Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive...
Gespeichert in:
Veröffentlicht in: | Journal of fire sciences 2019-07, Vol.37 (4-6), p.303-319 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 319 |
---|---|
container_issue | 4-6 |
container_start_page | 303 |
container_title | Journal of fire sciences |
container_volume | 37 |
creator | Huang, Xianjia Wang, Yuhong Zeng, Wuyong Peng, Lan Cheng, Anthony CH Chow, WK |
description | Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model. |
doi_str_mv | 10.1177/0734904119860410 |
format | Article |
fullrecord | <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_0734904119860410</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_0734904119860410</sage_id><sourcerecordid>10.1177_0734904119860410</sourcerecordid><originalsourceid>FETCH-LOGICAL-c318t-9c9b05ebae1aa1d7c994b2e002767d910352b3fb0533bc8f06c815adb37bde883</originalsourceid><addsrcrecordid>eNp1UMtKAzEUDaJgre5d5geiSTPTJEspvkBwo-vhJnNTU-ZFkiLd-elmqCAIrs7iPO49h5BrwW-EUOqWK1kZXglh9LoAPyELUUvONK_MKVnMNJv5c3KR0o7zlZBKLMjXZuwniLnHIdOM_YQR8j4ixZRDDzmMAx09BdrvuxymDlkHB4zUge2Q5ggH6kORf4b8QdvgPcY56UhDjDBscc5ONAwlxXVjwpa636OX5MxDl_DqB5fk_eH-bfPEXl4fnzd3L8xJoTMzzlheowUUAKJVzpjKrrD0UGvVGsFlvbLSF42U1mnP106LGlorlW1Ra7kk_Jjr4phSRN9MsRSMh0bwZl6w-btgsbCjJcEWm924j0P58H_9N6Kwc60</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment</title><source>SAGE Journals</source><creator>Huang, Xianjia ; Wang, Yuhong ; Zeng, Wuyong ; Peng, Lan ; Cheng, Anthony CH ; Chow, WK</creator><creatorcontrib>Huang, Xianjia ; Wang, Yuhong ; Zeng, Wuyong ; Peng, Lan ; Cheng, Anthony CH ; Chow, WK</creatorcontrib><description>Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model.</description><identifier>ISSN: 0734-9041</identifier><identifier>EISSN: 1530-8049</identifier><identifier>DOI: 10.1177/0734904119860410</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Journal of fire sciences, 2019-07, Vol.37 (4-6), p.303-319</ispartof><rights>The Author(s) 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c318t-9c9b05ebae1aa1d7c994b2e002767d910352b3fb0533bc8f06c815adb37bde883</citedby><cites>FETCH-LOGICAL-c318t-9c9b05ebae1aa1d7c994b2e002767d910352b3fb0533bc8f06c815adb37bde883</cites><orcidid>0000-0001-8398-3126</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/0734904119860410$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/0734904119860410$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids></links><search><creatorcontrib>Huang, Xianjia</creatorcontrib><creatorcontrib>Wang, Yuhong</creatorcontrib><creatorcontrib>Zeng, Wuyong</creatorcontrib><creatorcontrib>Peng, Lan</creatorcontrib><creatorcontrib>Cheng, Anthony CH</creatorcontrib><creatorcontrib>Chow, WK</creatorcontrib><title>Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment</title><title>Journal of fire sciences</title><description>Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model.</description><issn>0734-9041</issn><issn>1530-8049</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp1UMtKAzEUDaJgre5d5geiSTPTJEspvkBwo-vhJnNTU-ZFkiLd-elmqCAIrs7iPO49h5BrwW-EUOqWK1kZXglh9LoAPyELUUvONK_MKVnMNJv5c3KR0o7zlZBKLMjXZuwniLnHIdOM_YQR8j4ixZRDDzmMAx09BdrvuxymDlkHB4zUge2Q5ggH6kORf4b8QdvgPcY56UhDjDBscc5ONAwlxXVjwpa636OX5MxDl_DqB5fk_eH-bfPEXl4fnzd3L8xJoTMzzlheowUUAKJVzpjKrrD0UGvVGsFlvbLSF42U1mnP106LGlorlW1Ra7kk_Jjr4phSRN9MsRSMh0bwZl6w-btgsbCjJcEWm924j0P58H_9N6Kwc60</recordid><startdate>20190701</startdate><enddate>20190701</enddate><creator>Huang, Xianjia</creator><creator>Wang, Yuhong</creator><creator>Zeng, Wuyong</creator><creator>Peng, Lan</creator><creator>Cheng, Anthony CH</creator><creator>Chow, WK</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-8398-3126</orcidid></search><sort><creationdate>20190701</creationdate><title>Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment</title><author>Huang, Xianjia ; Wang, Yuhong ; Zeng, Wuyong ; Peng, Lan ; Cheng, Anthony CH ; Chow, WK</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c318t-9c9b05ebae1aa1d7c994b2e002767d910352b3fb0533bc8f06c815adb37bde883</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Huang, Xianjia</creatorcontrib><creatorcontrib>Wang, Yuhong</creatorcontrib><creatorcontrib>Zeng, Wuyong</creatorcontrib><creatorcontrib>Peng, Lan</creatorcontrib><creatorcontrib>Cheng, Anthony CH</creatorcontrib><creatorcontrib>Chow, WK</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of fire sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huang, Xianjia</au><au>Wang, Yuhong</au><au>Zeng, Wuyong</au><au>Peng, Lan</au><au>Cheng, Anthony CH</au><au>Chow, WK</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment</atitle><jtitle>Journal of fire sciences</jtitle><date>2019-07-01</date><risdate>2019</risdate><volume>37</volume><issue>4-6</issue><spage>303</spage><epage>319</epage><pages>303-319</pages><issn>0734-9041</issn><eissn>1530-8049</eissn><abstract>Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/0734904119860410</doi><tpages>17</tpages><orcidid>https://orcid.org/0000-0001-8398-3126</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0734-9041 |
ispartof | Journal of fire sciences, 2019-07, Vol.37 (4-6), p.303-319 |
issn | 0734-9041 1530-8049 |
language | eng |
recordid | cdi_crossref_primary_10_1177_0734904119860410 |
source | SAGE Journals |
title | Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T13%3A39%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Compartment%20temperature%20estimation%20of%20a%20multiple-layer%20cable%20tray%20fire%20with%20different%20cable%20arrangements%20in%20a%20closed%20compartment&rft.jtitle=Journal%20of%20fire%20sciences&rft.au=Huang,%20Xianjia&rft.date=2019-07-01&rft.volume=37&rft.issue=4-6&rft.spage=303&rft.epage=319&rft.pages=303-319&rft.issn=0734-9041&rft.eissn=1530-8049&rft_id=info:doi/10.1177/0734904119860410&rft_dat=%3Csage_cross%3E10.1177_0734904119860410%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_0734904119860410&rfr_iscdi=true |