Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment

Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of fire sciences 2019-07, Vol.37 (4-6), p.303-319
Hauptverfasser: Huang, Xianjia, Wang, Yuhong, Zeng, Wuyong, Peng, Lan, Cheng, Anthony CH, Chow, WK
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 319
container_issue 4-6
container_start_page 303
container_title Journal of fire sciences
container_volume 37
creator Huang, Xianjia
Wang, Yuhong
Zeng, Wuyong
Peng, Lan
Cheng, Anthony CH
Chow, WK
description Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model.
doi_str_mv 10.1177/0734904119860410
format Article
fullrecord <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_0734904119860410</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_0734904119860410</sage_id><sourcerecordid>10.1177_0734904119860410</sourcerecordid><originalsourceid>FETCH-LOGICAL-c318t-9c9b05ebae1aa1d7c994b2e002767d910352b3fb0533bc8f06c815adb37bde883</originalsourceid><addsrcrecordid>eNp1UMtKAzEUDaJgre5d5geiSTPTJEspvkBwo-vhJnNTU-ZFkiLd-elmqCAIrs7iPO49h5BrwW-EUOqWK1kZXglh9LoAPyELUUvONK_MKVnMNJv5c3KR0o7zlZBKLMjXZuwniLnHIdOM_YQR8j4ixZRDDzmMAx09BdrvuxymDlkHB4zUge2Q5ggH6kORf4b8QdvgPcY56UhDjDBscc5ONAwlxXVjwpa636OX5MxDl_DqB5fk_eH-bfPEXl4fnzd3L8xJoTMzzlheowUUAKJVzpjKrrD0UGvVGsFlvbLSF42U1mnP106LGlorlW1Ra7kk_Jjr4phSRN9MsRSMh0bwZl6w-btgsbCjJcEWm924j0P58H_9N6Kwc60</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment</title><source>SAGE Journals</source><creator>Huang, Xianjia ; Wang, Yuhong ; Zeng, Wuyong ; Peng, Lan ; Cheng, Anthony CH ; Chow, WK</creator><creatorcontrib>Huang, Xianjia ; Wang, Yuhong ; Zeng, Wuyong ; Peng, Lan ; Cheng, Anthony CH ; Chow, WK</creatorcontrib><description>Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model.</description><identifier>ISSN: 0734-9041</identifier><identifier>EISSN: 1530-8049</identifier><identifier>DOI: 10.1177/0734904119860410</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Journal of fire sciences, 2019-07, Vol.37 (4-6), p.303-319</ispartof><rights>The Author(s) 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c318t-9c9b05ebae1aa1d7c994b2e002767d910352b3fb0533bc8f06c815adb37bde883</citedby><cites>FETCH-LOGICAL-c318t-9c9b05ebae1aa1d7c994b2e002767d910352b3fb0533bc8f06c815adb37bde883</cites><orcidid>0000-0001-8398-3126</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/0734904119860410$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/0734904119860410$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids></links><search><creatorcontrib>Huang, Xianjia</creatorcontrib><creatorcontrib>Wang, Yuhong</creatorcontrib><creatorcontrib>Zeng, Wuyong</creatorcontrib><creatorcontrib>Peng, Lan</creatorcontrib><creatorcontrib>Cheng, Anthony CH</creatorcontrib><creatorcontrib>Chow, WK</creatorcontrib><title>Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment</title><title>Journal of fire sciences</title><description>Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model.</description><issn>0734-9041</issn><issn>1530-8049</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp1UMtKAzEUDaJgre5d5geiSTPTJEspvkBwo-vhJnNTU-ZFkiLd-elmqCAIrs7iPO49h5BrwW-EUOqWK1kZXglh9LoAPyELUUvONK_MKVnMNJv5c3KR0o7zlZBKLMjXZuwniLnHIdOM_YQR8j4ixZRDDzmMAx09BdrvuxymDlkHB4zUge2Q5ggH6kORf4b8QdvgPcY56UhDjDBscc5ONAwlxXVjwpa636OX5MxDl_DqB5fk_eH-bfPEXl4fnzd3L8xJoTMzzlheowUUAKJVzpjKrrD0UGvVGsFlvbLSF42U1mnP106LGlorlW1Ra7kk_Jjr4phSRN9MsRSMh0bwZl6w-btgsbCjJcEWm924j0P58H_9N6Kwc60</recordid><startdate>20190701</startdate><enddate>20190701</enddate><creator>Huang, Xianjia</creator><creator>Wang, Yuhong</creator><creator>Zeng, Wuyong</creator><creator>Peng, Lan</creator><creator>Cheng, Anthony CH</creator><creator>Chow, WK</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-8398-3126</orcidid></search><sort><creationdate>20190701</creationdate><title>Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment</title><author>Huang, Xianjia ; Wang, Yuhong ; Zeng, Wuyong ; Peng, Lan ; Cheng, Anthony CH ; Chow, WK</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c318t-9c9b05ebae1aa1d7c994b2e002767d910352b3fb0533bc8f06c815adb37bde883</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Huang, Xianjia</creatorcontrib><creatorcontrib>Wang, Yuhong</creatorcontrib><creatorcontrib>Zeng, Wuyong</creatorcontrib><creatorcontrib>Peng, Lan</creatorcontrib><creatorcontrib>Cheng, Anthony CH</creatorcontrib><creatorcontrib>Chow, WK</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of fire sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huang, Xianjia</au><au>Wang, Yuhong</au><au>Zeng, Wuyong</au><au>Peng, Lan</au><au>Cheng, Anthony CH</au><au>Chow, WK</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment</atitle><jtitle>Journal of fire sciences</jtitle><date>2019-07-01</date><risdate>2019</risdate><volume>37</volume><issue>4-6</issue><spage>303</spage><epage>319</epage><pages>303-319</pages><issn>0734-9041</issn><eissn>1530-8049</eissn><abstract>Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/0734904119860410</doi><tpages>17</tpages><orcidid>https://orcid.org/0000-0001-8398-3126</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0734-9041
ispartof Journal of fire sciences, 2019-07, Vol.37 (4-6), p.303-319
issn 0734-9041
1530-8049
language eng
recordid cdi_crossref_primary_10_1177_0734904119860410
source SAGE Journals
title Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T13%3A39%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Compartment%20temperature%20estimation%20of%20a%20multiple-layer%20cable%20tray%20fire%20with%20different%20cable%20arrangements%20in%20a%20closed%20compartment&rft.jtitle=Journal%20of%20fire%20sciences&rft.au=Huang,%20Xianjia&rft.date=2019-07-01&rft.volume=37&rft.issue=4-6&rft.spage=303&rft.epage=319&rft.pages=303-319&rft.issn=0734-9041&rft.eissn=1530-8049&rft_id=info:doi/10.1177/0734904119860410&rft_dat=%3Csage_cross%3E10.1177_0734904119860410%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_0734904119860410&rfr_iscdi=true