Improving the Wettability of Thin-Film Rotating Disk Electrodes for Reliable Activity Evaluation of Oxygen Electrocatalysts by Triggering Oxygen Reduction at the Catalyst-Electrolyte-Bubble Triple Phase Boundaries

Thin-filmed rotating disk electrode (RDE) measurement has been intensively used for activity evaluation of electrocatalysts for a wide range of energy conversion reactions. Besides the need of a high quality homogenous catalyst thin film, a good electrode wettability with aqueous electrolytes is hig...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Electrochemical Society 2018-01, Vol.165 (7), p.F436-F440
Hauptverfasser: Wang, Ruozheng, Jiang, Wulv, Xia, Dongsheng, Liu, Tian, Gan, Lin
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page F440
container_issue 7
container_start_page F436
container_title Journal of the Electrochemical Society
container_volume 165
creator Wang, Ruozheng
Jiang, Wulv
Xia, Dongsheng
Liu, Tian
Gan, Lin
description Thin-filmed rotating disk electrode (RDE) measurement has been intensively used for activity evaluation of electrocatalysts for a wide range of energy conversion reactions. Besides the need of a high quality homogenous catalyst thin film, a good electrode wettability with aqueous electrolytes is highly desired for reliable activity evaluation of electrocatalysts yet experimentally remains a non-trivial task, showing the feasible formation of visible or invisible bubbles at the electrode-electrolyte interface. In this work, we report a robust and facile approach to eliminate these bubbles and thus improve the wettability of thin-filmed catalyst electrodes. This was achieved by triggering oxygen reduction at the catalyst-electrolyte-bubble triple phase boundaries at a constant reductive potential for a while, leading to oxygen depletion in the bubbles and thereby vanishing the bubbles. We also show that, insufficient wettability of catalyst electrodes due to visible or even invisible bubbles can lead to under-estimated activity for oxygen evolution reaction as well as inaccurate oxygen reduction reaction measurement. Once eliminating these bubbles at constant reductive potentials, the RDE tests can be repeatable and more reliable for activity assessment of electrocatalysts.
doi_str_mv 10.1149/2.0371807jes
format Article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1149_2_0371807jes</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>0371807JES</sourcerecordid><originalsourceid>FETCH-LOGICAL-c306t-f444e62e78d04dc6a794ed74eb6d041860133150d5e7efcac89ce815bd0bd3cb3</originalsourceid><addsrcrecordid>eNptkc9OAjEQhxujiYjefIAePbjYst0_HAFBSUgwBONx021noVi2pO0S90F9H3cB48XTpJPv-82kg9A9JT1K2eCp3yNhQlOSbMFdoA4dsChIKKWXqEMIDQMWR_Qa3Ti3bZ40ZUkHfc92e2sOqlxjvwH8Ad7zXGnla2wKvNqoMpgqvcNL47lvqWflPvFEg_DWSHC4MBYvQSuea8BD4dWhdScHrqtGMGUbs_iq11D-WoJ7rmvnHc5rvLJqvQbbJp-pJchKHE3ujzuNz3xw9nXtIRhVeTuw0fdNedtwB3hkqlJyq8DdoquCawd359pF79PJavwazBcvs_FwHoiQxD4oGGMQ9yFJJWFSxDwZMJAJgzxuGjSNm08LaURkBAkUgot0ICClUS5JLkORh130eMoV1jhnocj2Vu24rTNKsvYkWT_7O0mDP5xwZfbZ1lS2bJb7H_0B-vqSeg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Improving the Wettability of Thin-Film Rotating Disk Electrodes for Reliable Activity Evaluation of Oxygen Electrocatalysts by Triggering Oxygen Reduction at the Catalyst-Electrolyte-Bubble Triple Phase Boundaries</title><source>IOP Publishing Journals</source><creator>Wang, Ruozheng ; Jiang, Wulv ; Xia, Dongsheng ; Liu, Tian ; Gan, Lin</creator><creatorcontrib>Wang, Ruozheng ; Jiang, Wulv ; Xia, Dongsheng ; Liu, Tian ; Gan, Lin</creatorcontrib><description>Thin-filmed rotating disk electrode (RDE) measurement has been intensively used for activity evaluation of electrocatalysts for a wide range of energy conversion reactions. Besides the need of a high quality homogenous catalyst thin film, a good electrode wettability with aqueous electrolytes is highly desired for reliable activity evaluation of electrocatalysts yet experimentally remains a non-trivial task, showing the feasible formation of visible or invisible bubbles at the electrode-electrolyte interface. In this work, we report a robust and facile approach to eliminate these bubbles and thus improve the wettability of thin-filmed catalyst electrodes. This was achieved by triggering oxygen reduction at the catalyst-electrolyte-bubble triple phase boundaries at a constant reductive potential for a while, leading to oxygen depletion in the bubbles and thereby vanishing the bubbles. We also show that, insufficient wettability of catalyst electrodes due to visible or even invisible bubbles can lead to under-estimated activity for oxygen evolution reaction as well as inaccurate oxygen reduction reaction measurement. Once eliminating these bubbles at constant reductive potentials, the RDE tests can be repeatable and more reliable for activity assessment of electrocatalysts.</description><identifier>ISSN: 0013-4651</identifier><identifier>EISSN: 1945-7111</identifier><identifier>DOI: 10.1149/2.0371807jes</identifier><language>eng</language><publisher>The Electrochemical Society</publisher><ispartof>Journal of the Electrochemical Society, 2018-01, Vol.165 (7), p.F436-F440</ispartof><rights>The Author(s) 2018. Published by ECS.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c306t-f444e62e78d04dc6a794ed74eb6d041860133150d5e7efcac89ce815bd0bd3cb3</citedby><cites>FETCH-LOGICAL-c306t-f444e62e78d04dc6a794ed74eb6d041860133150d5e7efcac89ce815bd0bd3cb3</cites><orcidid>0000-0003-3486-6016</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1149/2.0371807jes/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>314,776,780,4010,27902,27903,27904,53824</link.rule.ids></links><search><creatorcontrib>Wang, Ruozheng</creatorcontrib><creatorcontrib>Jiang, Wulv</creatorcontrib><creatorcontrib>Xia, Dongsheng</creatorcontrib><creatorcontrib>Liu, Tian</creatorcontrib><creatorcontrib>Gan, Lin</creatorcontrib><title>Improving the Wettability of Thin-Film Rotating Disk Electrodes for Reliable Activity Evaluation of Oxygen Electrocatalysts by Triggering Oxygen Reduction at the Catalyst-Electrolyte-Bubble Triple Phase Boundaries</title><title>Journal of the Electrochemical Society</title><addtitle>J. Electrochem. Soc</addtitle><description>Thin-filmed rotating disk electrode (RDE) measurement has been intensively used for activity evaluation of electrocatalysts for a wide range of energy conversion reactions. Besides the need of a high quality homogenous catalyst thin film, a good electrode wettability with aqueous electrolytes is highly desired for reliable activity evaluation of electrocatalysts yet experimentally remains a non-trivial task, showing the feasible formation of visible or invisible bubbles at the electrode-electrolyte interface. In this work, we report a robust and facile approach to eliminate these bubbles and thus improve the wettability of thin-filmed catalyst electrodes. This was achieved by triggering oxygen reduction at the catalyst-electrolyte-bubble triple phase boundaries at a constant reductive potential for a while, leading to oxygen depletion in the bubbles and thereby vanishing the bubbles. We also show that, insufficient wettability of catalyst electrodes due to visible or even invisible bubbles can lead to under-estimated activity for oxygen evolution reaction as well as inaccurate oxygen reduction reaction measurement. Once eliminating these bubbles at constant reductive potentials, the RDE tests can be repeatable and more reliable for activity assessment of electrocatalysts.</description><issn>0013-4651</issn><issn>1945-7111</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><recordid>eNptkc9OAjEQhxujiYjefIAePbjYst0_HAFBSUgwBONx021noVi2pO0S90F9H3cB48XTpJPv-82kg9A9JT1K2eCp3yNhQlOSbMFdoA4dsChIKKWXqEMIDQMWR_Qa3Ti3bZ40ZUkHfc92e2sOqlxjvwH8Ad7zXGnla2wKvNqoMpgqvcNL47lvqWflPvFEg_DWSHC4MBYvQSuea8BD4dWhdScHrqtGMGUbs_iq11D-WoJ7rmvnHc5rvLJqvQbbJp-pJchKHE3ujzuNz3xw9nXtIRhVeTuw0fdNedtwB3hkqlJyq8DdoquCawd359pF79PJavwazBcvs_FwHoiQxD4oGGMQ9yFJJWFSxDwZMJAJgzxuGjSNm08LaURkBAkUgot0ICClUS5JLkORh130eMoV1jhnocj2Vu24rTNKsvYkWT_7O0mDP5xwZfbZ1lS2bJb7H_0B-vqSeg</recordid><startdate>201801</startdate><enddate>201801</enddate><creator>Wang, Ruozheng</creator><creator>Jiang, Wulv</creator><creator>Xia, Dongsheng</creator><creator>Liu, Tian</creator><creator>Gan, Lin</creator><general>The Electrochemical Society</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-3486-6016</orcidid></search><sort><creationdate>201801</creationdate><title>Improving the Wettability of Thin-Film Rotating Disk Electrodes for Reliable Activity Evaluation of Oxygen Electrocatalysts by Triggering Oxygen Reduction at the Catalyst-Electrolyte-Bubble Triple Phase Boundaries</title><author>Wang, Ruozheng ; Jiang, Wulv ; Xia, Dongsheng ; Liu, Tian ; Gan, Lin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c306t-f444e62e78d04dc6a794ed74eb6d041860133150d5e7efcac89ce815bd0bd3cb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Ruozheng</creatorcontrib><creatorcontrib>Jiang, Wulv</creatorcontrib><creatorcontrib>Xia, Dongsheng</creatorcontrib><creatorcontrib>Liu, Tian</creatorcontrib><creatorcontrib>Gan, Lin</creatorcontrib><collection>IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><jtitle>Journal of the Electrochemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Ruozheng</au><au>Jiang, Wulv</au><au>Xia, Dongsheng</au><au>Liu, Tian</au><au>Gan, Lin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Improving the Wettability of Thin-Film Rotating Disk Electrodes for Reliable Activity Evaluation of Oxygen Electrocatalysts by Triggering Oxygen Reduction at the Catalyst-Electrolyte-Bubble Triple Phase Boundaries</atitle><jtitle>Journal of the Electrochemical Society</jtitle><addtitle>J. Electrochem. Soc</addtitle><date>2018-01</date><risdate>2018</risdate><volume>165</volume><issue>7</issue><spage>F436</spage><epage>F440</epage><pages>F436-F440</pages><issn>0013-4651</issn><eissn>1945-7111</eissn><abstract>Thin-filmed rotating disk electrode (RDE) measurement has been intensively used for activity evaluation of electrocatalysts for a wide range of energy conversion reactions. Besides the need of a high quality homogenous catalyst thin film, a good electrode wettability with aqueous electrolytes is highly desired for reliable activity evaluation of electrocatalysts yet experimentally remains a non-trivial task, showing the feasible formation of visible or invisible bubbles at the electrode-electrolyte interface. In this work, we report a robust and facile approach to eliminate these bubbles and thus improve the wettability of thin-filmed catalyst electrodes. This was achieved by triggering oxygen reduction at the catalyst-electrolyte-bubble triple phase boundaries at a constant reductive potential for a while, leading to oxygen depletion in the bubbles and thereby vanishing the bubbles. We also show that, insufficient wettability of catalyst electrodes due to visible or even invisible bubbles can lead to under-estimated activity for oxygen evolution reaction as well as inaccurate oxygen reduction reaction measurement. Once eliminating these bubbles at constant reductive potentials, the RDE tests can be repeatable and more reliable for activity assessment of electrocatalysts.</abstract><pub>The Electrochemical Society</pub><doi>10.1149/2.0371807jes</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0003-3486-6016</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0013-4651
ispartof Journal of the Electrochemical Society, 2018-01, Vol.165 (7), p.F436-F440
issn 0013-4651
1945-7111
language eng
recordid cdi_crossref_primary_10_1149_2_0371807jes
source IOP Publishing Journals
title Improving the Wettability of Thin-Film Rotating Disk Electrodes for Reliable Activity Evaluation of Oxygen Electrocatalysts by Triggering Oxygen Reduction at the Catalyst-Electrolyte-Bubble Triple Phase Boundaries
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T11%3A37%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Improving%20the%20Wettability%20of%20Thin-Film%20Rotating%20Disk%20Electrodes%20for%20Reliable%20Activity%20Evaluation%20of%20Oxygen%20Electrocatalysts%20by%20Triggering%20Oxygen%20Reduction%20at%20the%20Catalyst-Electrolyte-Bubble%20Triple%20Phase%20Boundaries&rft.jtitle=Journal%20of%20the%20Electrochemical%20Society&rft.au=Wang,%20Ruozheng&rft.date=2018-01&rft.volume=165&rft.issue=7&rft.spage=F436&rft.epage=F440&rft.pages=F436-F440&rft.issn=0013-4651&rft.eissn=1945-7111&rft_id=info:doi/10.1149/2.0371807jes&rft_dat=%3Ciop_cross%3E0371807JES%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true