Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography
A cerium-target X-ray tube is useful in performing cone-beam K-edge angiography because K-series characteristic X-rays from the cerium target are absorbed effectively by iodine-based contrast media. The X-ray generator consists of a main controller and a unit with a high-voltage circuit and a fixed...
Gespeichert in:
Veröffentlicht in: | Japanese Journal of Applied Physics 2005-11, Vol.44 (11R), p.8204 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 11R |
container_start_page | 8204 |
container_title | Japanese Journal of Applied Physics |
container_volume | 44 |
creator | Sato, Eiichi Tanaka, Etsuro Mori, Hidezo Kawai, Toshiaki Inoue, Takashi Ogawa, Akira Yamadera, Akira Sato, Shigehiro Ito, Fumihito Takayama, Kazuyoshi Onagawa, Jun Ido, Hideaki |
description | A cerium-target X-ray tube is useful in performing cone-beam K-edge angiography because K-series characteristic X-rays from the cerium target are absorbed effectively by iodine-based contrast media. The X-ray generator consists of a main controller and a unit with a high-voltage circuit and a fixed anode X-ray tube. The tube is a 1.0-mm-focus diode with a cerium target and a 0.5-mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively. Cerium Kα rays were selected out using a barium sulfate filter, and the X-ray intensities without filtering and with a barium sulfate filter were 209 and 16.8 µGy/s, respectively, at 1.0 m from the source with a tube voltage of 60 kV and a current of 0.40 mA. Angiography was performed with an X-ray film using the filter and iodine-based microspheres 15 µm in diameter. In the angiography of nonliving animals, we observed fine blood vessels approximately 100 µm in diameter with high contrasts. |
doi_str_mv | 10.1143/JJAP.44.8204 |
format | Article |
fullrecord | <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1143_JJAP_44_8204</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1143_JJAP_44_8204</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-6ca559789f50463256dfeeb15eeba57ec3e748a6240cd9d3cad3110ee1d9eb7d3</originalsourceid><addsrcrecordid>eNotz81OhDAUBeDGaCKO7nyAPoDFlt7ys0SCo-MkmvgTd-ROe2EwDpCCC97eIbo5J2dzko-xayVDpUDfbjb5SwgQppGEExYoDYkAGZtTFkgZKQFZFJ2zi3H8Os7YgArY3Qf6Fqe270bedrwg3_4c-KfwOPPXgezkkWPneNntsbPk-JMoXUM875q2bzwO-_mSndX4PdLVf6_Y-335VjyI7fP6sci3wupUTyK2aEyWpFltJMQ6MrGriXbKHANNQlZTAinGEUjrMqctOq2UJFIuo13i9Ird_P1a34-jp7oafHtAP1dKVou_WvwVQLX49S_5D01Z</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Sato, Eiichi ; Tanaka, Etsuro ; Mori, Hidezo ; Kawai, Toshiaki ; Inoue, Takashi ; Ogawa, Akira ; Yamadera, Akira ; Sato, Shigehiro ; Ito, Fumihito ; Takayama, Kazuyoshi ; Onagawa, Jun ; Ido, Hideaki</creator><creatorcontrib>Sato, Eiichi ; Tanaka, Etsuro ; Mori, Hidezo ; Kawai, Toshiaki ; Inoue, Takashi ; Ogawa, Akira ; Yamadera, Akira ; Sato, Shigehiro ; Ito, Fumihito ; Takayama, Kazuyoshi ; Onagawa, Jun ; Ido, Hideaki</creatorcontrib><description>A cerium-target X-ray tube is useful in performing cone-beam K-edge angiography because K-series characteristic X-rays from the cerium target are absorbed effectively by iodine-based contrast media. The X-ray generator consists of a main controller and a unit with a high-voltage circuit and a fixed anode X-ray tube. The tube is a 1.0-mm-focus diode with a cerium target and a 0.5-mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively. Cerium Kα rays were selected out using a barium sulfate filter, and the X-ray intensities without filtering and with a barium sulfate filter were 209 and 16.8 µGy/s, respectively, at 1.0 m from the source with a tube voltage of 60 kV and a current of 0.40 mA. Angiography was performed with an X-ray film using the filter and iodine-based microspheres 15 µm in diameter. In the angiography of nonliving animals, we observed fine blood vessels approximately 100 µm in diameter with high contrasts.</description><identifier>ISSN: 0021-4922</identifier><identifier>EISSN: 1347-4065</identifier><identifier>DOI: 10.1143/JJAP.44.8204</identifier><language>eng</language><ispartof>Japanese Journal of Applied Physics, 2005-11, Vol.44 (11R), p.8204</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-6ca559789f50463256dfeeb15eeba57ec3e748a6240cd9d3cad3110ee1d9eb7d3</citedby><cites>FETCH-LOGICAL-c383t-6ca559789f50463256dfeeb15eeba57ec3e748a6240cd9d3cad3110ee1d9eb7d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Sato, Eiichi</creatorcontrib><creatorcontrib>Tanaka, Etsuro</creatorcontrib><creatorcontrib>Mori, Hidezo</creatorcontrib><creatorcontrib>Kawai, Toshiaki</creatorcontrib><creatorcontrib>Inoue, Takashi</creatorcontrib><creatorcontrib>Ogawa, Akira</creatorcontrib><creatorcontrib>Yamadera, Akira</creatorcontrib><creatorcontrib>Sato, Shigehiro</creatorcontrib><creatorcontrib>Ito, Fumihito</creatorcontrib><creatorcontrib>Takayama, Kazuyoshi</creatorcontrib><creatorcontrib>Onagawa, Jun</creatorcontrib><creatorcontrib>Ido, Hideaki</creatorcontrib><title>Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography</title><title>Japanese Journal of Applied Physics</title><description>A cerium-target X-ray tube is useful in performing cone-beam K-edge angiography because K-series characteristic X-rays from the cerium target are absorbed effectively by iodine-based contrast media. The X-ray generator consists of a main controller and a unit with a high-voltage circuit and a fixed anode X-ray tube. The tube is a 1.0-mm-focus diode with a cerium target and a 0.5-mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively. Cerium Kα rays were selected out using a barium sulfate filter, and the X-ray intensities without filtering and with a barium sulfate filter were 209 and 16.8 µGy/s, respectively, at 1.0 m from the source with a tube voltage of 60 kV and a current of 0.40 mA. Angiography was performed with an X-ray film using the filter and iodine-based microspheres 15 µm in diameter. In the angiography of nonliving animals, we observed fine blood vessels approximately 100 µm in diameter with high contrasts.</description><issn>0021-4922</issn><issn>1347-4065</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNotz81OhDAUBeDGaCKO7nyAPoDFlt7ys0SCo-MkmvgTd-ROe2EwDpCCC97eIbo5J2dzko-xayVDpUDfbjb5SwgQppGEExYoDYkAGZtTFkgZKQFZFJ2zi3H8Os7YgArY3Qf6Fqe270bedrwg3_4c-KfwOPPXgezkkWPneNntsbPk-JMoXUM875q2bzwO-_mSndX4PdLVf6_Y-335VjyI7fP6sci3wupUTyK2aEyWpFltJMQ6MrGriXbKHANNQlZTAinGEUjrMqctOq2UJFIuo13i9Ird_P1a34-jp7oafHtAP1dKVou_WvwVQLX49S_5D01Z</recordid><startdate>20051101</startdate><enddate>20051101</enddate><creator>Sato, Eiichi</creator><creator>Tanaka, Etsuro</creator><creator>Mori, Hidezo</creator><creator>Kawai, Toshiaki</creator><creator>Inoue, Takashi</creator><creator>Ogawa, Akira</creator><creator>Yamadera, Akira</creator><creator>Sato, Shigehiro</creator><creator>Ito, Fumihito</creator><creator>Takayama, Kazuyoshi</creator><creator>Onagawa, Jun</creator><creator>Ido, Hideaki</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20051101</creationdate><title>Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography</title><author>Sato, Eiichi ; Tanaka, Etsuro ; Mori, Hidezo ; Kawai, Toshiaki ; Inoue, Takashi ; Ogawa, Akira ; Yamadera, Akira ; Sato, Shigehiro ; Ito, Fumihito ; Takayama, Kazuyoshi ; Onagawa, Jun ; Ido, Hideaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-6ca559789f50463256dfeeb15eeba57ec3e748a6240cd9d3cad3110ee1d9eb7d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sato, Eiichi</creatorcontrib><creatorcontrib>Tanaka, Etsuro</creatorcontrib><creatorcontrib>Mori, Hidezo</creatorcontrib><creatorcontrib>Kawai, Toshiaki</creatorcontrib><creatorcontrib>Inoue, Takashi</creatorcontrib><creatorcontrib>Ogawa, Akira</creatorcontrib><creatorcontrib>Yamadera, Akira</creatorcontrib><creatorcontrib>Sato, Shigehiro</creatorcontrib><creatorcontrib>Ito, Fumihito</creatorcontrib><creatorcontrib>Takayama, Kazuyoshi</creatorcontrib><creatorcontrib>Onagawa, Jun</creatorcontrib><creatorcontrib>Ido, Hideaki</creatorcontrib><collection>CrossRef</collection><jtitle>Japanese Journal of Applied Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sato, Eiichi</au><au>Tanaka, Etsuro</au><au>Mori, Hidezo</au><au>Kawai, Toshiaki</au><au>Inoue, Takashi</au><au>Ogawa, Akira</au><au>Yamadera, Akira</au><au>Sato, Shigehiro</au><au>Ito, Fumihito</au><au>Takayama, Kazuyoshi</au><au>Onagawa, Jun</au><au>Ido, Hideaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography</atitle><jtitle>Japanese Journal of Applied Physics</jtitle><date>2005-11-01</date><risdate>2005</risdate><volume>44</volume><issue>11R</issue><spage>8204</spage><pages>8204-</pages><issn>0021-4922</issn><eissn>1347-4065</eissn><abstract>A cerium-target X-ray tube is useful in performing cone-beam K-edge angiography because K-series characteristic X-rays from the cerium target are absorbed effectively by iodine-based contrast media. The X-ray generator consists of a main controller and a unit with a high-voltage circuit and a fixed anode X-ray tube. The tube is a 1.0-mm-focus diode with a cerium target and a 0.5-mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively. Cerium Kα rays were selected out using a barium sulfate filter, and the X-ray intensities without filtering and with a barium sulfate filter were 209 and 16.8 µGy/s, respectively, at 1.0 m from the source with a tube voltage of 60 kV and a current of 0.40 mA. Angiography was performed with an X-ray film using the filter and iodine-based microspheres 15 µm in diameter. In the angiography of nonliving animals, we observed fine blood vessels approximately 100 µm in diameter with high contrasts.</abstract><doi>10.1143/JJAP.44.8204</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-4922 |
ispartof | Japanese Journal of Applied Physics, 2005-11, Vol.44 (11R), p.8204 |
issn | 0021-4922 1347-4065 |
language | eng |
recordid | cdi_crossref_primary_10_1143_JJAP_44_8204 |
source | IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link |
title | Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T10%3A37%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Variations%20in%20Cerium%20X-ray%20Spectra%20and%20Enhanced%20K-Edge%20Angiography&rft.jtitle=Japanese%20Journal%20of%20Applied%20Physics&rft.au=Sato,%20Eiichi&rft.date=2005-11-01&rft.volume=44&rft.issue=11R&rft.spage=8204&rft.pages=8204-&rft.issn=0021-4922&rft.eissn=1347-4065&rft_id=info:doi/10.1143/JJAP.44.8204&rft_dat=%3Ccrossref%3E10_1143_JJAP_44_8204%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |