Pattern Etching of Ta X-ray Mask Absorber on SiC Membrane by Inductively Coupled Plasma

Patterning of an X-ray mask absorber after Si back-etching is desirable from the viewpoint of the pattern placement accuracy. We investigated Ta X-ray absorber etching on an SiC membrane equipped on a mask frame using a low-stress CrN hard mask and an ICP etcher with a He cooling system. In this sys...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Japanese Journal of Applied Physics 1998-07, Vol.37 (7A), p.L824
Hauptverfasser: Iba, Yoshihisa, Kumasaka, Fumiaki, Aoyama, Hajime, Taguchi, Takao, Yamabe, Masaki
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Patterning of an X-ray mask absorber after Si back-etching is desirable from the viewpoint of the pattern placement accuracy. We investigated Ta X-ray absorber etching on an SiC membrane equipped on a mask frame using a low-stress CrN hard mask and an ICP etcher with a He cooling system. In this system, the membrane temperature and the self-bias voltage could be controlled. A 40-nm-thick CrN film was etched using a 200-nm-thick resist and Cl 2 and O 2 gases with a selectivity of 0.72 and a vertical sidewall. A 400-nm-thick Ta film was etched using Cl 2 gas at an electrode temperature of -10°C and a low gas pressure of 0.1 Pa. A high selectivity of Ta to CrN, 42, was obtained, and lines and spaces patterns below 0.1 µm with vertical sidewalls could be fabricated.
ISSN:0021-4922
1347-4065
DOI:10.1143/JJAP.37.L824