Recent Results on 500 MHz Superconducting Cavities at KEK

Two 500 MHz spherical cavities built from Nb were tested. Locations of weak spots at breakdown field levels were detected and surface processing was repeated to remove the weak spots. Q 0 and the accelerating field gradient were improved after each reprocessing. Q 0 =4.1–4.2×10 9 and E acc =6.5 MV/m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Japanese Journal of Applied Physics 1982-01, Vol.21 (2A), p.L86
Hauptverfasser: Kojima, Yuzo, Furuya, Takaaki, Nakazato, Toshiharu
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2A
container_start_page L86
container_title Japanese Journal of Applied Physics
container_volume 21
creator Kojima, Yuzo
Furuya, Takaaki
Nakazato, Toshiharu
description Two 500 MHz spherical cavities built from Nb were tested. Locations of weak spots at breakdown field levels were detected and surface processing was repeated to remove the weak spots. Q 0 and the accelerating field gradient were improved after each reprocessing. Q 0 =4.1–4.2×10 9 and E acc =6.5 MV/m at 4.2 K, Q 0 =3.2–4.8×10 10 and E acc =7.0 MV/m at 1.8 K were obtained for both cavities.
doi_str_mv 10.1143/JJAP.21.L86
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1143_JJAP_21_L86</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1143_JJAP_21_L86</sourcerecordid><originalsourceid>FETCH-LOGICAL-c326t-42ef385d4d4abb4d19abfc989c5c4b2ffb1682c85f7814a319b81591acc391823</originalsourceid><addsrcrecordid>eNotz09LwzAcxvEgCtbpyTeQu7Tmlz9dchxlOreKMvUckjSRymxHkgr66t3Q08P38sAHoWsgFQBnt-v14rmiULWyPkEFMD4vOanFKSoIoVByRek5ukjp45C14FAgtfXODxlvfZp2OeFxwIIQ_Lj6wS_T3kc3Dt3kcj-848Z89bn3CZuMN8vNJToLZpf81f_O0Nvd8rVZle3T_UOzaEvHaJ1LTn1gUnS848Za3oEyNjgllROOWxqChVpSJ0WYS-CGgbIShALjHFMgKZuhm79fF8eUog96H_tPE781EH1U66NaU9AHNfsFHE1I1w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Recent Results on 500 MHz Superconducting Cavities at KEK</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Kojima, Yuzo ; Furuya, Takaaki ; Nakazato, Toshiharu</creator><creatorcontrib>Kojima, Yuzo ; Furuya, Takaaki ; Nakazato, Toshiharu</creatorcontrib><description>Two 500 MHz spherical cavities built from Nb were tested. Locations of weak spots at breakdown field levels were detected and surface processing was repeated to remove the weak spots. Q 0 and the accelerating field gradient were improved after each reprocessing. Q 0 =4.1–4.2×10 9 and E acc =6.5 MV/m at 4.2 K, Q 0 =3.2–4.8×10 10 and E acc =7.0 MV/m at 1.8 K were obtained for both cavities.</description><identifier>ISSN: 0021-4922</identifier><identifier>EISSN: 1347-4065</identifier><identifier>DOI: 10.1143/JJAP.21.L86</identifier><language>eng</language><ispartof>Japanese Journal of Applied Physics, 1982-01, Vol.21 (2A), p.L86</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c326t-42ef385d4d4abb4d19abfc989c5c4b2ffb1682c85f7814a319b81591acc391823</citedby><cites>FETCH-LOGICAL-c326t-42ef385d4d4abb4d19abfc989c5c4b2ffb1682c85f7814a319b81591acc391823</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Kojima, Yuzo</creatorcontrib><creatorcontrib>Furuya, Takaaki</creatorcontrib><creatorcontrib>Nakazato, Toshiharu</creatorcontrib><title>Recent Results on 500 MHz Superconducting Cavities at KEK</title><title>Japanese Journal of Applied Physics</title><description>Two 500 MHz spherical cavities built from Nb were tested. Locations of weak spots at breakdown field levels were detected and surface processing was repeated to remove the weak spots. Q 0 and the accelerating field gradient were improved after each reprocessing. Q 0 =4.1–4.2×10 9 and E acc =6.5 MV/m at 4.2 K, Q 0 =3.2–4.8×10 10 and E acc =7.0 MV/m at 1.8 K were obtained for both cavities.</description><issn>0021-4922</issn><issn>1347-4065</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1982</creationdate><recordtype>article</recordtype><recordid>eNotz09LwzAcxvEgCtbpyTeQu7Tmlz9dchxlOreKMvUckjSRymxHkgr66t3Q08P38sAHoWsgFQBnt-v14rmiULWyPkEFMD4vOanFKSoIoVByRek5ukjp45C14FAgtfXODxlvfZp2OeFxwIIQ_Lj6wS_T3kc3Dt3kcj-848Z89bn3CZuMN8vNJToLZpf81f_O0Nvd8rVZle3T_UOzaEvHaJ1LTn1gUnS848Za3oEyNjgllROOWxqChVpSJ0WYS-CGgbIShALjHFMgKZuhm79fF8eUog96H_tPE781EH1U66NaU9AHNfsFHE1I1w</recordid><startdate>19820101</startdate><enddate>19820101</enddate><creator>Kojima, Yuzo</creator><creator>Furuya, Takaaki</creator><creator>Nakazato, Toshiharu</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19820101</creationdate><title>Recent Results on 500 MHz Superconducting Cavities at KEK</title><author>Kojima, Yuzo ; Furuya, Takaaki ; Nakazato, Toshiharu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c326t-42ef385d4d4abb4d19abfc989c5c4b2ffb1682c85f7814a319b81591acc391823</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1982</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kojima, Yuzo</creatorcontrib><creatorcontrib>Furuya, Takaaki</creatorcontrib><creatorcontrib>Nakazato, Toshiharu</creatorcontrib><collection>CrossRef</collection><jtitle>Japanese Journal of Applied Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kojima, Yuzo</au><au>Furuya, Takaaki</au><au>Nakazato, Toshiharu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Recent Results on 500 MHz Superconducting Cavities at KEK</atitle><jtitle>Japanese Journal of Applied Physics</jtitle><date>1982-01-01</date><risdate>1982</risdate><volume>21</volume><issue>2A</issue><spage>L86</spage><pages>L86-</pages><issn>0021-4922</issn><eissn>1347-4065</eissn><abstract>Two 500 MHz spherical cavities built from Nb were tested. Locations of weak spots at breakdown field levels were detected and surface processing was repeated to remove the weak spots. Q 0 and the accelerating field gradient were improved after each reprocessing. Q 0 =4.1–4.2×10 9 and E acc =6.5 MV/m at 4.2 K, Q 0 =3.2–4.8×10 10 and E acc =7.0 MV/m at 1.8 K were obtained for both cavities.</abstract><doi>10.1143/JJAP.21.L86</doi></addata></record>
fulltext fulltext
identifier ISSN: 0021-4922
ispartof Japanese Journal of Applied Physics, 1982-01, Vol.21 (2A), p.L86
issn 0021-4922
1347-4065
language eng
recordid cdi_crossref_primary_10_1143_JJAP_21_L86
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
title Recent Results on 500 MHz Superconducting Cavities at KEK
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T23%3A47%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Recent%20Results%20on%20500%20MHz%20Superconducting%20Cavities%20at%20KEK&rft.jtitle=Japanese%20Journal%20of%20Applied%20Physics&rft.au=Kojima,%20Yuzo&rft.date=1982-01-01&rft.volume=21&rft.issue=2A&rft.spage=L86&rft.pages=L86-&rft.issn=0021-4922&rft.eissn=1347-4065&rft_id=info:doi/10.1143/JJAP.21.L86&rft_dat=%3Ccrossref%3E10_1143_JJAP_21_L86%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true