Acoustic-emission location of flaws during multiple-run welding of contours with complex shapes

A modified tabular method for locating acoustic-emission signals, which is intended for determining the coordinates of flaws when inspecting a multiple-run welding process with a lower error rate, and the result of using this method for determining the coordinates of flaws when welding a circular co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Russian journal of nondestructive testing 2016-05, Vol.52 (5), p.261-268
Hauptverfasser: Stepanova, L. N., Ramazanov, I. S., Kireenko, V. V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A modified tabular method for locating acoustic-emission signals, which is intended for determining the coordinates of flaws when inspecting a multiple-run welding process with a lower error rate, and the result of using this method for determining the coordinates of flaws when welding a circular contour using a piezoelectric antenna, which consists of four acoustic-emission transducers, are considered. It is shown experimentally that the application of the modified tabular method allowed an increase in the accuracy of determining the coordinates of introduced flaws when using the acoustic-emission testing method.
ISSN:1061-8309
1608-3385
DOI:10.1134/S1061830916050065