Experience gained from carrying out ultrasonic cleaning of fuel assemblies and control and protection system assemblies in the Novovoronezh NPP unit 3

A growth of deposits on fuel assembly elements was revealed during operation of the Novovoronezh NPP Unit 3 starting from 1997. This growth caused progressive reduction of coolant flow rate through the reactor core and increase of pressure difference across the assemblies, which eventually led to th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Thermal engineering 2014, Vol.61 (2), p.107-116
Hauptverfasser: Gorburov, V. I., Shvarov, V. A., Vitkovskii, S. L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 116
container_issue 2
container_start_page 107
container_title Thermal engineering
container_volume 61
creator Gorburov, V. I.
Shvarov, V. A.
Vitkovskii, S. L.
description A growth of deposits on fuel assembly elements was revealed during operation of the Novovoronezh NPP Unit 3 starting from 1997. This growth caused progressive reduction of coolant flow rate through the reactor core and increase of pressure difference across the assemblies, which eventually led to the need to reduce the power unit output and then to shut down the power unit. In view of these circumstances, it was decided to develop an installation for ultrasonic cleaning of fuel assemblies. The following conclusions were drawn with regard of this installation after completion of all stages of its development, commissioning, and improvement: no detrimental effect of ultrasound on the integrity of fuel assemblies was revealed, whereas the cleaning effect on the fuel assemblies subjected to ultrasonic treatment and improvement of their thermal-hydraulic characteristics are obvious. With these measures implemented, it became possible to clean all fuel assemblies in the core in 2011, to achieve better thermal-hydraulic characteristics, and to avoid reduction of power output and off-scheduled outages of Unit 3.
doi_str_mv 10.1134/S0040601514020050
format Article
fullrecord <record><control><sourceid>crossref_sprin</sourceid><recordid>TN_cdi_crossref_primary_10_1134_S0040601514020050</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1134_S0040601514020050</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1550-e1adb2c567fbc32788d2e02a3a58ea9d2f25714827eaf69e34fb8c550df528293</originalsourceid><addsrcrecordid>eNp9UMtOwzAQtBBIlMIHcNsfCNhOnKRHVJWHVJVKwDlynHXrKrEr20GUD-F7SVsOSEhoD_uYmdXuEHLN6A1jaXb7QmlGc8oEyyinVNATMmJCiCRPKTsloz2c7PFzchHCZmizjIkR-Zp9bNEbtAphJY3FBrR3HSjp_c7YFbg-Qt9GL4OzRoFqUdrDXIPusQUZAnZ1azCAtA0oZ6N37aHeehdRReMshF2I2P0mGwtxjbBw70N4Z_FzDYvlEnprIqSX5EzLNuDVTx6Tt_vZ6_QxmT8_PE3v5okanqMJMtnUXIm80LVKeVGWDUfKZSpFiXLScM1FwbKSFyh1PsE003WpBmWjBS_5JB0TdtyrvAvBo6623nTS7ypGq72x1R9jBw0_asLAtSv01cb13g5n_iP6BmUlfWo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Experience gained from carrying out ultrasonic cleaning of fuel assemblies and control and protection system assemblies in the Novovoronezh NPP unit 3</title><source>SpringerNature Journals</source><creator>Gorburov, V. I. ; Shvarov, V. A. ; Vitkovskii, S. L.</creator><creatorcontrib>Gorburov, V. I. ; Shvarov, V. A. ; Vitkovskii, S. L.</creatorcontrib><description>A growth of deposits on fuel assembly elements was revealed during operation of the Novovoronezh NPP Unit 3 starting from 1997. This growth caused progressive reduction of coolant flow rate through the reactor core and increase of pressure difference across the assemblies, which eventually led to the need to reduce the power unit output and then to shut down the power unit. In view of these circumstances, it was decided to develop an installation for ultrasonic cleaning of fuel assemblies. The following conclusions were drawn with regard of this installation after completion of all stages of its development, commissioning, and improvement: no detrimental effect of ultrasound on the integrity of fuel assemblies was revealed, whereas the cleaning effect on the fuel assemblies subjected to ultrasonic treatment and improvement of their thermal-hydraulic characteristics are obvious. With these measures implemented, it became possible to clean all fuel assemblies in the core in 2011, to achieve better thermal-hydraulic characteristics, and to avoid reduction of power output and off-scheduled outages of Unit 3.</description><identifier>ISSN: 0040-6015</identifier><identifier>EISSN: 1555-6301</identifier><identifier>DOI: 10.1134/S0040601514020050</identifier><language>eng</language><publisher>Boston: Springer US</publisher><subject>Engineering ; Engineering Thermodynamics ; Heat and Mass Transfer ; Nuclear Power Stations</subject><ispartof>Thermal engineering, 2014, Vol.61 (2), p.107-116</ispartof><rights>Pleiades Publishing, Inc. 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1134/S0040601514020050$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1134/S0040601514020050$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids></links><search><creatorcontrib>Gorburov, V. I.</creatorcontrib><creatorcontrib>Shvarov, V. A.</creatorcontrib><creatorcontrib>Vitkovskii, S. L.</creatorcontrib><title>Experience gained from carrying out ultrasonic cleaning of fuel assemblies and control and protection system assemblies in the Novovoronezh NPP unit 3</title><title>Thermal engineering</title><addtitle>Therm. Eng</addtitle><description>A growth of deposits on fuel assembly elements was revealed during operation of the Novovoronezh NPP Unit 3 starting from 1997. This growth caused progressive reduction of coolant flow rate through the reactor core and increase of pressure difference across the assemblies, which eventually led to the need to reduce the power unit output and then to shut down the power unit. In view of these circumstances, it was decided to develop an installation for ultrasonic cleaning of fuel assemblies. The following conclusions were drawn with regard of this installation after completion of all stages of its development, commissioning, and improvement: no detrimental effect of ultrasound on the integrity of fuel assemblies was revealed, whereas the cleaning effect on the fuel assemblies subjected to ultrasonic treatment and improvement of their thermal-hydraulic characteristics are obvious. With these measures implemented, it became possible to clean all fuel assemblies in the core in 2011, to achieve better thermal-hydraulic characteristics, and to avoid reduction of power output and off-scheduled outages of Unit 3.</description><subject>Engineering</subject><subject>Engineering Thermodynamics</subject><subject>Heat and Mass Transfer</subject><subject>Nuclear Power Stations</subject><issn>0040-6015</issn><issn>1555-6301</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNp9UMtOwzAQtBBIlMIHcNsfCNhOnKRHVJWHVJVKwDlynHXrKrEr20GUD-F7SVsOSEhoD_uYmdXuEHLN6A1jaXb7QmlGc8oEyyinVNATMmJCiCRPKTsloz2c7PFzchHCZmizjIkR-Zp9bNEbtAphJY3FBrR3HSjp_c7YFbg-Qt9GL4OzRoFqUdrDXIPusQUZAnZ1azCAtA0oZ6N37aHeehdRReMshF2I2P0mGwtxjbBw70N4Z_FzDYvlEnprIqSX5EzLNuDVTx6Tt_vZ6_QxmT8_PE3v5okanqMJMtnUXIm80LVKeVGWDUfKZSpFiXLScM1FwbKSFyh1PsE003WpBmWjBS_5JB0TdtyrvAvBo6623nTS7ypGq72x1R9jBw0_asLAtSv01cb13g5n_iP6BmUlfWo</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Gorburov, V. I.</creator><creator>Shvarov, V. A.</creator><creator>Vitkovskii, S. L.</creator><general>Springer US</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2014</creationdate><title>Experience gained from carrying out ultrasonic cleaning of fuel assemblies and control and protection system assemblies in the Novovoronezh NPP unit 3</title><author>Gorburov, V. I. ; Shvarov, V. A. ; Vitkovskii, S. L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1550-e1adb2c567fbc32788d2e02a3a58ea9d2f25714827eaf69e34fb8c550df528293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Engineering</topic><topic>Engineering Thermodynamics</topic><topic>Heat and Mass Transfer</topic><topic>Nuclear Power Stations</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gorburov, V. I.</creatorcontrib><creatorcontrib>Shvarov, V. A.</creatorcontrib><creatorcontrib>Vitkovskii, S. L.</creatorcontrib><collection>CrossRef</collection><jtitle>Thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gorburov, V. I.</au><au>Shvarov, V. A.</au><au>Vitkovskii, S. L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experience gained from carrying out ultrasonic cleaning of fuel assemblies and control and protection system assemblies in the Novovoronezh NPP unit 3</atitle><jtitle>Thermal engineering</jtitle><stitle>Therm. Eng</stitle><date>2014</date><risdate>2014</risdate><volume>61</volume><issue>2</issue><spage>107</spage><epage>116</epage><pages>107-116</pages><issn>0040-6015</issn><eissn>1555-6301</eissn><abstract>A growth of deposits on fuel assembly elements was revealed during operation of the Novovoronezh NPP Unit 3 starting from 1997. This growth caused progressive reduction of coolant flow rate through the reactor core and increase of pressure difference across the assemblies, which eventually led to the need to reduce the power unit output and then to shut down the power unit. In view of these circumstances, it was decided to develop an installation for ultrasonic cleaning of fuel assemblies. The following conclusions were drawn with regard of this installation after completion of all stages of its development, commissioning, and improvement: no detrimental effect of ultrasound on the integrity of fuel assemblies was revealed, whereas the cleaning effect on the fuel assemblies subjected to ultrasonic treatment and improvement of their thermal-hydraulic characteristics are obvious. With these measures implemented, it became possible to clean all fuel assemblies in the core in 2011, to achieve better thermal-hydraulic characteristics, and to avoid reduction of power output and off-scheduled outages of Unit 3.</abstract><cop>Boston</cop><pub>Springer US</pub><doi>10.1134/S0040601514020050</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0040-6015
ispartof Thermal engineering, 2014, Vol.61 (2), p.107-116
issn 0040-6015
1555-6301
language eng
recordid cdi_crossref_primary_10_1134_S0040601514020050
source SpringerNature Journals
subjects Engineering
Engineering Thermodynamics
Heat and Mass Transfer
Nuclear Power Stations
title Experience gained from carrying out ultrasonic cleaning of fuel assemblies and control and protection system assemblies in the Novovoronezh NPP unit 3
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T19%3A41%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_sprin&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experience%20gained%20from%20carrying%20out%20ultrasonic%20cleaning%20of%20fuel%20assemblies%20and%20control%20and%20protection%20system%20assemblies%20in%20the%20Novovoronezh%20NPP%20unit%203&rft.jtitle=Thermal%20engineering&rft.au=Gorburov,%20V.%20I.&rft.date=2014&rft.volume=61&rft.issue=2&rft.spage=107&rft.epage=116&rft.pages=107-116&rft.issn=0040-6015&rft.eissn=1555-6301&rft_id=info:doi/10.1134/S0040601514020050&rft_dat=%3Ccrossref_sprin%3E10_1134_S0040601514020050%3C/crossref_sprin%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true