Results from expert tests of the TP-100A boiler at the Lugansk thermal power station during the combustion of lean coal and anthracite culm with addition of RA-GEN-F anaklarid

Results from expert tests of separated combustion of Grade T and Grade ASh anthracite culm in the TP-100A boiler No. 15 at the Lugansk thermal power station carried out with and without addition of RA-GEN-F anaklarid are presented. The possibility of extending the boiler load adjustment range and ex...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Thermal engineering 2012, Vol.59 (8), p.573-579
Hauptverfasser: Mikhailov, V. E., Tupitsyn, S. P., Sokolov, V. V., Chebakova, G. F., Malygin, V. I., Yazykov, Yu. V., Kharchenko, A. V., Chetverikov, A. N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 579
container_issue 8
container_start_page 573
container_title Thermal engineering
container_volume 59
creator Mikhailov, V. E.
Tupitsyn, S. P.
Sokolov, V. V.
Chebakova, G. F.
Malygin, V. I.
Yazykov, Yu. V.
Kharchenko, A. V.
Chetverikov, A. N.
description Results from expert tests of separated combustion of Grade T and Grade ASh anthracite culm in the TP-100A boiler No. 15 at the Lugansk thermal power station carried out with and without addition of RA-GEN-F anaklarid are presented. The possibility of extending the boiler load adjustment range and excluding the use of natural gas for supporting the flame at minimal loads is considered.
doi_str_mv 10.1134/S0040601512080095
format Article
fullrecord <record><control><sourceid>crossref_sprin</sourceid><recordid>TN_cdi_crossref_primary_10_1134_S0040601512080095</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1134_S0040601512080095</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2035-458fa06969aeb434f2716506c659584ac8fe8d863d432a85df78aea786eeef963</originalsourceid><addsrcrecordid>eNp9UM1OwzAMjhBIjMEDcMsLFJI2ydLjNG0DaQI0xrny2mTL1jZTkgp4Kl6RdIMTEgfL9vdj2UbolpI7SjN2_0oII4JQTlMiCcn5GRpQznkiMkLP0aCnk56_RFfe72LLGOUD9LVUvquDx9rZBquPg3IBB-UjYjUOW4VXLwklZIzX1tTKYQhHdNFtoPX7vnYN1Phg3yPpAwRjW1x1zrSbo7C0zbrzRzQOrBW0EYoGaKsYYeugNCHKurrB7yZsMVSV-ZUvx8l8-pTMohL2NThTXaMLDbVXNz95iN5m09XkIVk8zx8n40VSpiTjCeNSAxG5yEGtWcZ0OqKCE1EKnnPJoJRayUqKrGJZCpJXeiRBwUgKpZTORTZE9DS3dNZ7p3RxcKYB91lQUvQfL_58PHrSk8cf-vOVK3a2c21c8x_TN9oTg_8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Results from expert tests of the TP-100A boiler at the Lugansk thermal power station during the combustion of lean coal and anthracite culm with addition of RA-GEN-F anaklarid</title><source>SpringerLink Journals - AutoHoldings</source><creator>Mikhailov, V. E. ; Tupitsyn, S. P. ; Sokolov, V. V. ; Chebakova, G. F. ; Malygin, V. I. ; Yazykov, Yu. V. ; Kharchenko, A. V. ; Chetverikov, A. N.</creator><creatorcontrib>Mikhailov, V. E. ; Tupitsyn, S. P. ; Sokolov, V. V. ; Chebakova, G. F. ; Malygin, V. I. ; Yazykov, Yu. V. ; Kharchenko, A. V. ; Chetverikov, A. N.</creatorcontrib><description>Results from expert tests of separated combustion of Grade T and Grade ASh anthracite culm in the TP-100A boiler No. 15 at the Lugansk thermal power station carried out with and without addition of RA-GEN-F anaklarid are presented. The possibility of extending the boiler load adjustment range and excluding the use of natural gas for supporting the flame at minimal loads is considered.</description><identifier>ISSN: 0040-6015</identifier><identifier>EISSN: 1555-6301</identifier><identifier>DOI: 10.1134/S0040601512080095</identifier><language>eng</language><publisher>Dordrecht: SP MAIK Nauka/Interperiodica</publisher><subject>Engineering ; Engineering Thermodynamics ; Heat and Mass Transfer</subject><ispartof>Thermal engineering, 2012, Vol.59 (8), p.573-579</ispartof><rights>Pleiades Publishing, Ltd. 2012</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2035-458fa06969aeb434f2716506c659584ac8fe8d863d432a85df78aea786eeef963</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1134/S0040601512080095$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1134/S0040601512080095$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids></links><search><creatorcontrib>Mikhailov, V. E.</creatorcontrib><creatorcontrib>Tupitsyn, S. P.</creatorcontrib><creatorcontrib>Sokolov, V. V.</creatorcontrib><creatorcontrib>Chebakova, G. F.</creatorcontrib><creatorcontrib>Malygin, V. I.</creatorcontrib><creatorcontrib>Yazykov, Yu. V.</creatorcontrib><creatorcontrib>Kharchenko, A. V.</creatorcontrib><creatorcontrib>Chetverikov, A. N.</creatorcontrib><title>Results from expert tests of the TP-100A boiler at the Lugansk thermal power station during the combustion of lean coal and anthracite culm with addition of RA-GEN-F anaklarid</title><title>Thermal engineering</title><addtitle>Therm. Eng</addtitle><description>Results from expert tests of separated combustion of Grade T and Grade ASh anthracite culm in the TP-100A boiler No. 15 at the Lugansk thermal power station carried out with and without addition of RA-GEN-F anaklarid are presented. The possibility of extending the boiler load adjustment range and excluding the use of natural gas for supporting the flame at minimal loads is considered.</description><subject>Engineering</subject><subject>Engineering Thermodynamics</subject><subject>Heat and Mass Transfer</subject><issn>0040-6015</issn><issn>1555-6301</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNp9UM1OwzAMjhBIjMEDcMsLFJI2ydLjNG0DaQI0xrny2mTL1jZTkgp4Kl6RdIMTEgfL9vdj2UbolpI7SjN2_0oII4JQTlMiCcn5GRpQznkiMkLP0aCnk56_RFfe72LLGOUD9LVUvquDx9rZBquPg3IBB-UjYjUOW4VXLwklZIzX1tTKYQhHdNFtoPX7vnYN1Phg3yPpAwRjW1x1zrSbo7C0zbrzRzQOrBW0EYoGaKsYYeugNCHKurrB7yZsMVSV-ZUvx8l8-pTMohL2NThTXaMLDbVXNz95iN5m09XkIVk8zx8n40VSpiTjCeNSAxG5yEGtWcZ0OqKCE1EKnnPJoJRayUqKrGJZCpJXeiRBwUgKpZTORTZE9DS3dNZ7p3RxcKYB91lQUvQfL_58PHrSk8cf-vOVK3a2c21c8x_TN9oTg_8</recordid><startdate>2012</startdate><enddate>2012</enddate><creator>Mikhailov, V. E.</creator><creator>Tupitsyn, S. P.</creator><creator>Sokolov, V. V.</creator><creator>Chebakova, G. F.</creator><creator>Malygin, V. I.</creator><creator>Yazykov, Yu. V.</creator><creator>Kharchenko, A. V.</creator><creator>Chetverikov, A. N.</creator><general>SP MAIK Nauka/Interperiodica</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2012</creationdate><title>Results from expert tests of the TP-100A boiler at the Lugansk thermal power station during the combustion of lean coal and anthracite culm with addition of RA-GEN-F anaklarid</title><author>Mikhailov, V. E. ; Tupitsyn, S. P. ; Sokolov, V. V. ; Chebakova, G. F. ; Malygin, V. I. ; Yazykov, Yu. V. ; Kharchenko, A. V. ; Chetverikov, A. N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2035-458fa06969aeb434f2716506c659584ac8fe8d863d432a85df78aea786eeef963</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Engineering</topic><topic>Engineering Thermodynamics</topic><topic>Heat and Mass Transfer</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mikhailov, V. E.</creatorcontrib><creatorcontrib>Tupitsyn, S. P.</creatorcontrib><creatorcontrib>Sokolov, V. V.</creatorcontrib><creatorcontrib>Chebakova, G. F.</creatorcontrib><creatorcontrib>Malygin, V. I.</creatorcontrib><creatorcontrib>Yazykov, Yu. V.</creatorcontrib><creatorcontrib>Kharchenko, A. V.</creatorcontrib><creatorcontrib>Chetverikov, A. N.</creatorcontrib><collection>CrossRef</collection><jtitle>Thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mikhailov, V. E.</au><au>Tupitsyn, S. P.</au><au>Sokolov, V. V.</au><au>Chebakova, G. F.</au><au>Malygin, V. I.</au><au>Yazykov, Yu. V.</au><au>Kharchenko, A. V.</au><au>Chetverikov, A. N.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Results from expert tests of the TP-100A boiler at the Lugansk thermal power station during the combustion of lean coal and anthracite culm with addition of RA-GEN-F anaklarid</atitle><jtitle>Thermal engineering</jtitle><stitle>Therm. Eng</stitle><date>2012</date><risdate>2012</risdate><volume>59</volume><issue>8</issue><spage>573</spage><epage>579</epage><pages>573-579</pages><issn>0040-6015</issn><eissn>1555-6301</eissn><abstract>Results from expert tests of separated combustion of Grade T and Grade ASh anthracite culm in the TP-100A boiler No. 15 at the Lugansk thermal power station carried out with and without addition of RA-GEN-F anaklarid are presented. The possibility of extending the boiler load adjustment range and excluding the use of natural gas for supporting the flame at minimal loads is considered.</abstract><cop>Dordrecht</cop><pub>SP MAIK Nauka/Interperiodica</pub><doi>10.1134/S0040601512080095</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0040-6015
ispartof Thermal engineering, 2012, Vol.59 (8), p.573-579
issn 0040-6015
1555-6301
language eng
recordid cdi_crossref_primary_10_1134_S0040601512080095
source SpringerLink Journals - AutoHoldings
subjects Engineering
Engineering Thermodynamics
Heat and Mass Transfer
title Results from expert tests of the TP-100A boiler at the Lugansk thermal power station during the combustion of lean coal and anthracite culm with addition of RA-GEN-F anaklarid
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T10%3A06%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_sprin&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Results%20from%20expert%20tests%20of%20the%20TP-100A%20boiler%20at%20the%20Lugansk%20thermal%20power%20station%20during%20the%20combustion%20of%20lean%20coal%20and%20anthracite%20culm%20with%20addition%20of%20RA-GEN-F%20anaklarid&rft.jtitle=Thermal%20engineering&rft.au=Mikhailov,%20V.%20E.&rft.date=2012&rft.volume=59&rft.issue=8&rft.spage=573&rft.epage=579&rft.pages=573-579&rft.issn=0040-6015&rft.eissn=1555-6301&rft_id=info:doi/10.1134/S0040601512080095&rft_dat=%3Ccrossref_sprin%3E10_1134_S0040601512080095%3C/crossref_sprin%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true