Detection of sub-micron lipid droplets using transmission-mode attenuation measurements in emulsion phantoms and liver

In liver transplantation, donor liver viability is assessed by the both the amount and type of fat present in the organ. General guidelines dictate that livers with more than 30% fat should not be transplanted; however, a lack of available donor organs has led to the consideration of livers with mor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 2014-10, Vol.136 (4_Supplement), p.2157-2157
Hauptverfasser: Kreider, Wayne, Tabatabai, Ameen, Maxwell, Adam D., Wang, Yak-Nam
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2157
container_issue 4_Supplement
container_start_page 2157
container_title The Journal of the Acoustical Society of America
container_volume 136
creator Kreider, Wayne
Tabatabai, Ameen
Maxwell, Adam D.
Wang, Yak-Nam
description In liver transplantation, donor liver viability is assessed by the both the amount and type of fat present in the organ. General guidelines dictate that livers with more than 30% fat should not be transplanted; however, a lack of available donor organs has led to the consideration of livers with more fat. As a part of this process, it is desirable to distinguish micro-vesicular fat (< 1 µm droplets) from macro-vesicular fat (~10 µm droplets). A method of evaluating the relative amounts of micro- and macro-fat is proposed based on transmission-mode ultrasound attenuation measurements. For an emulsion of one liquid in another, attenuation comprises both intrinsic losses in each medium and excess attenuation associated with interactions between media. Using an established coupled-phase model, the excess attenuation associated with a monodisperse population of lipid droplets was calculated with physical properties representative of both liver tissue and dairy products. Calculations predict that excess attenuation can exceed intrinsic attenuation and that a well-defined peak in excess attenuation at 1 MHz should occur for droplets around 0.8 µm in diameter. Such predictions are consistent with preliminary transmission-mode measurements in dairy products. [Work supported by NIH grants EB017857, EB007643, EB016118, and T32 DK007779.]
doi_str_mv 10.1121/1.4899801
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1121_1_4899801</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1121_1_4899801</sourcerecordid><originalsourceid>FETCH-crossref_primary_10_1121_1_48998013</originalsourceid><addsrcrecordid>eNqVj8FqwzAQREVpIW6bQ_5grz0o0Tp2sM9pSz4gd6HG61bBkoxWCvTvo5T8QE_DwJsZRogVqjVijRtcN13fdwofRIVtrWTX1s2jqJRSKJt-t1uIZ-ZzsW237StxeadEp2SDhzAC5y_p7CkWN9nZDjDEME-UGDJb_w0pGs_OMhdeujAQmJTIZ_NX4MhwjuTIl4D1QC5PNxLmH-NTcAzGD6X4QvFVPI1mYlre9UW8fX4c9wdZtpkjjXqO1pn4q1Hp2zGN-n5s-x_2ClGVVjQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Detection of sub-micron lipid droplets using transmission-mode attenuation measurements in emulsion phantoms and liver</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><source>AIP Acoustical Society of America</source><creator>Kreider, Wayne ; Tabatabai, Ameen ; Maxwell, Adam D. ; Wang, Yak-Nam</creator><creatorcontrib>Kreider, Wayne ; Tabatabai, Ameen ; Maxwell, Adam D. ; Wang, Yak-Nam</creatorcontrib><description>In liver transplantation, donor liver viability is assessed by the both the amount and type of fat present in the organ. General guidelines dictate that livers with more than 30% fat should not be transplanted; however, a lack of available donor organs has led to the consideration of livers with more fat. As a part of this process, it is desirable to distinguish micro-vesicular fat (&lt; 1 µm droplets) from macro-vesicular fat (~10 µm droplets). A method of evaluating the relative amounts of micro- and macro-fat is proposed based on transmission-mode ultrasound attenuation measurements. For an emulsion of one liquid in another, attenuation comprises both intrinsic losses in each medium and excess attenuation associated with interactions between media. Using an established coupled-phase model, the excess attenuation associated with a monodisperse population of lipid droplets was calculated with physical properties representative of both liver tissue and dairy products. Calculations predict that excess attenuation can exceed intrinsic attenuation and that a well-defined peak in excess attenuation at 1 MHz should occur for droplets around 0.8 µm in diameter. Such predictions are consistent with preliminary transmission-mode measurements in dairy products. [Work supported by NIH grants EB017857, EB007643, EB016118, and T32 DK007779.]</description><identifier>ISSN: 0001-4966</identifier><identifier>EISSN: 1520-8524</identifier><identifier>DOI: 10.1121/1.4899801</identifier><language>eng</language><ispartof>The Journal of the Acoustical Society of America, 2014-10, Vol.136 (4_Supplement), p.2157-2157</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>207,208,314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Kreider, Wayne</creatorcontrib><creatorcontrib>Tabatabai, Ameen</creatorcontrib><creatorcontrib>Maxwell, Adam D.</creatorcontrib><creatorcontrib>Wang, Yak-Nam</creatorcontrib><title>Detection of sub-micron lipid droplets using transmission-mode attenuation measurements in emulsion phantoms and liver</title><title>The Journal of the Acoustical Society of America</title><description>In liver transplantation, donor liver viability is assessed by the both the amount and type of fat present in the organ. General guidelines dictate that livers with more than 30% fat should not be transplanted; however, a lack of available donor organs has led to the consideration of livers with more fat. As a part of this process, it is desirable to distinguish micro-vesicular fat (&lt; 1 µm droplets) from macro-vesicular fat (~10 µm droplets). A method of evaluating the relative amounts of micro- and macro-fat is proposed based on transmission-mode ultrasound attenuation measurements. For an emulsion of one liquid in another, attenuation comprises both intrinsic losses in each medium and excess attenuation associated with interactions between media. Using an established coupled-phase model, the excess attenuation associated with a monodisperse population of lipid droplets was calculated with physical properties representative of both liver tissue and dairy products. Calculations predict that excess attenuation can exceed intrinsic attenuation and that a well-defined peak in excess attenuation at 1 MHz should occur for droplets around 0.8 µm in diameter. Such predictions are consistent with preliminary transmission-mode measurements in dairy products. [Work supported by NIH grants EB017857, EB007643, EB016118, and T32 DK007779.]</description><issn>0001-4966</issn><issn>1520-8524</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqVj8FqwzAQREVpIW6bQ_5grz0o0Tp2sM9pSz4gd6HG61bBkoxWCvTvo5T8QE_DwJsZRogVqjVijRtcN13fdwofRIVtrWTX1s2jqJRSKJt-t1uIZ-ZzsW237StxeadEp2SDhzAC5y_p7CkWN9nZDjDEME-UGDJb_w0pGs_OMhdeujAQmJTIZ_NX4MhwjuTIl4D1QC5PNxLmH-NTcAzGD6X4QvFVPI1mYlre9UW8fX4c9wdZtpkjjXqO1pn4q1Hp2zGN-n5s-x_2ClGVVjQ</recordid><startdate>20141001</startdate><enddate>20141001</enddate><creator>Kreider, Wayne</creator><creator>Tabatabai, Ameen</creator><creator>Maxwell, Adam D.</creator><creator>Wang, Yak-Nam</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20141001</creationdate><title>Detection of sub-micron lipid droplets using transmission-mode attenuation measurements in emulsion phantoms and liver</title><author>Kreider, Wayne ; Tabatabai, Ameen ; Maxwell, Adam D. ; Wang, Yak-Nam</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-crossref_primary_10_1121_1_48998013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kreider, Wayne</creatorcontrib><creatorcontrib>Tabatabai, Ameen</creatorcontrib><creatorcontrib>Maxwell, Adam D.</creatorcontrib><creatorcontrib>Wang, Yak-Nam</creatorcontrib><collection>CrossRef</collection><jtitle>The Journal of the Acoustical Society of America</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kreider, Wayne</au><au>Tabatabai, Ameen</au><au>Maxwell, Adam D.</au><au>Wang, Yak-Nam</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Detection of sub-micron lipid droplets using transmission-mode attenuation measurements in emulsion phantoms and liver</atitle><jtitle>The Journal of the Acoustical Society of America</jtitle><date>2014-10-01</date><risdate>2014</risdate><volume>136</volume><issue>4_Supplement</issue><spage>2157</spage><epage>2157</epage><pages>2157-2157</pages><issn>0001-4966</issn><eissn>1520-8524</eissn><abstract>In liver transplantation, donor liver viability is assessed by the both the amount and type of fat present in the organ. General guidelines dictate that livers with more than 30% fat should not be transplanted; however, a lack of available donor organs has led to the consideration of livers with more fat. As a part of this process, it is desirable to distinguish micro-vesicular fat (&lt; 1 µm droplets) from macro-vesicular fat (~10 µm droplets). A method of evaluating the relative amounts of micro- and macro-fat is proposed based on transmission-mode ultrasound attenuation measurements. For an emulsion of one liquid in another, attenuation comprises both intrinsic losses in each medium and excess attenuation associated with interactions between media. Using an established coupled-phase model, the excess attenuation associated with a monodisperse population of lipid droplets was calculated with physical properties representative of both liver tissue and dairy products. Calculations predict that excess attenuation can exceed intrinsic attenuation and that a well-defined peak in excess attenuation at 1 MHz should occur for droplets around 0.8 µm in diameter. Such predictions are consistent with preliminary transmission-mode measurements in dairy products. [Work supported by NIH grants EB017857, EB007643, EB016118, and T32 DK007779.]</abstract><doi>10.1121/1.4899801</doi></addata></record>
fulltext fulltext
identifier ISSN: 0001-4966
ispartof The Journal of the Acoustical Society of America, 2014-10, Vol.136 (4_Supplement), p.2157-2157
issn 0001-4966
1520-8524
language eng
recordid cdi_crossref_primary_10_1121_1_4899801
source AIP Journals Complete; Alma/SFX Local Collection; AIP Acoustical Society of America
title Detection of sub-micron lipid droplets using transmission-mode attenuation measurements in emulsion phantoms and liver
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T14%3A17%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Detection%20of%20sub-micron%20lipid%20droplets%20using%20transmission-mode%20attenuation%20measurements%20in%20emulsion%20phantoms%20and%20liver&rft.jtitle=The%20Journal%20of%20the%20Acoustical%20Society%20of%20America&rft.au=Kreider,%20Wayne&rft.date=2014-10-01&rft.volume=136&rft.issue=4_Supplement&rft.spage=2157&rft.epage=2157&rft.pages=2157-2157&rft.issn=0001-4966&rft.eissn=1520-8524&rft_id=info:doi/10.1121/1.4899801&rft_dat=%3Ccrossref%3E10_1121_1_4899801%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true